5 Service Fixture & Tools
5.1.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at "software download" on the "Support Information from NWBG/VDBG-PAVC" web-site in
"TSN system", together with Maintenance software.
5.2.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
No.
Parts No.
1
VFK1173
2
VFK1461
3
VFK1284
4
RFKZ0487
5
VFK1284
Table S1 Extension Cable List
Connection
FP6931 (MAIN) - CCD UNIT
FP6971 (MAIN) - LENS UNIT
FP6905 (MAIN) - BATTERY FPC
FP6903 (MAIN) - SIDE-R PCB
FP2502 (SIDE-R) - MONITOR FPC
11
Form
14PIN 0.5 FFC
20PIN 0.5 FFC
24PIN 0.5 FFC
35PIN 0.3 FFC
24PIN 0.5 FFC