Page 2
Inspection and maintenance should be safety practices. Contact your local Siemens representative performed on this equipment and before using these products to clean or equipment to which power has been (c) is trained in rendering first aid.
Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local Siemens sales office. The contents of this instruction manual shall not become part of or modify any prior or existing agreement, commitment or relationship.
The purpose of this manual is to help users develop safe and efficient procedures for the installation, operation and maintenance of the i-3 V2 I/O Modbus Controller. The i-3 V2 I/O Controller is used to control the operation of P1 Series with i-3 Control Data Rail Data Rail...
Chapter 2 i-3 V2 I/O Controller Introduction I/O Board The i-3 V2 I/O Controller consists of The main component of i-3 V2 I/O I/O printed circuit board, power supply, Controller is the I/O printed circuit fuse, switch, ribbon cables, mounting board.
Page 6
Chapter 2 i-3 V2 I/O Controller Switch input terminals (digital inputs) Analog inputs (TB6) Modbus addressing switches (TB1 – TB2) Two analog inputs to connect the 0-10 V Used to set the controllers Modbus address There are 20 switch input terminals output from light sensors.
Page 7
Chapter 2 i-3 V2 I/O Controller USB-RS485 converter kit Part No. 5WG1715-8XY02 Phoenix connector Part No. 1984028 FTD chip Part No. USB-RS485-WE-1800-BT Figure 2.4 USB Converter Kit...
Page 8
The RS-485 terminals are used to connect method operation of all SIPODs. It has 3 System (BAS) or any Modbus master. i-3 V2 I/O Controller to a Modbus Building positions, “All ON”, “Auto” and “All OFF.” Automation System (BAS). They also •...
LittleFuse KLDR002 or equivalent. Power switch An ON/OFF switch controls power to the Figure 2.7 i-3 V2 controller. Be sure to turn the power Power Switch and Fuse Housing switch OFF prior to removing the fuse from the controller. Ribbon cables A pair of 26-wire ribbon cables connect the I/O Board and the data rails.
Chapter 3 Control Input Mounting bracket Removing the cover DANGER The mounting bracket is a “C” shape Them I/O Controller cover must be removed steel plate that screws into the P1 to access the input wiring section. Follow Hazardous voltage. panel mounting rails.
Introduction The Analog Inputs can be used in any Registers 22 and 23 are for specifying i-3 V2 I/O Controller provides a set of control situation where digital inputs are used. Analog Output 1 Set value and Analog input terminals for wiring devices, such as They are specified by using input numbers Output 2 Set value.
Digital inputs common Figure 4-2 Input Terminals in the Input Wiring Section Common input types Table 4-1 lists the typical input types supported by i-3 Control Technology V2 system. Input Type Description Comments Digital input maintain toggle switch (2-wire) If the value changes, then invert the state Digital input maintain toggle switch (2-wire) –...
(which is more than one Refer to Modbus Map on page 14 for communication protocol or the output). Refer to Modbus Map table in more information. configuration software. Chapter 5 –Communication Protocols under “Configuring i-3 V2 I/O Controller” section for more information.
1792 (for input terminal 1) communications. to 1811 (for input terminal 20). The i-3 V2 I/O Controller will act as a Modbus Slave using Modbus RTU or 1. Using the i-3 V2 I/O Configurator 3. Assign the desired input type value,...
Page 15
Creating output groups Mapping input-to-output Refer to Modbus Map table on page 14 An output group consists of a set of By default, the factory assembled i-3 for additional information. SIPODs. To create an output group, follow V2 Controller input-to-output mapping these steps: is not set.
SP2 – Status of Pole 2 (for 2-pole PODs) minimum of one minute and maximum i-3 V2 I/O Controller in a Modbus network. of two minutes. This is equal to q if the second pole is closed.
Page 17
65536. groups defined) and the Input-Output To obtain this software, please contact Mapping Table (i.e., 1-to-1 mapping of Siemens at 800-427-2256. Software will 1.1. Analog Gain Tables 32 digital inputs to the first 32 outputs) be available for download online.
Page 18
Chapter 5 Communication Protocols Analog Gain If the analog feedback data from the light- ing sensor falls between 0 and threshold setting 1, Programmable Ramp sets the analog output to level 1. If the analog input data from the lighting sensor falls between threshold setting 1 and threshold setting 2, Programmable Ramp sets the analog output to level 2.
Appendix A Modbus Address Table Appendix B Circuits (SIPODs) Modbus Address Table Appendix C Modbus Coils, Discrete Inputs, Input Registers and Holding Registers Address Tables Appendix D Dimming Instructions Appendix E USB to RS485 Converter Driver Software Installations Instructions Appendix F Recommended input devices Appendix G Common Networking setups...
Page 24
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Coils Modbus Modbus Value Function Code Base 0 address 5 digit address (Read/Write*) Description 1 (Read Only) 00001 0 / 1 SIPOD 1 Open (0)/Close (1) 5 & 15 (Write Only) * 00002 0 / 1 SIPOD 2 Open (0)/Close (1)
Page 25
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Coils Modbus Modbus Value Function code base 0 address 5 digit address (Read/Write*) Description 00078 0 / 1 Output Group (Zone) 14, Open (0)/Close (1) 00079 0 / 1 Output Group (Zone) 15, Open (0)/Close (1) 00080 0 / 1...
Page 26
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Discrete inputs Modbus Modbus Value Function code Base 0 address 5 digit address (Read/Only) Description 2 (Read Only) 10001 0 / 1 Digital Input 1 Off (0)/On (1) 10002 0 / 1 Digital Input 2 Off (0)/On (1)
Page 27
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Input Registers Modbus Modbus Value Note Function code Base 0 address 5 digit address (Read/Only) Description 4 (Read Only) 30001 Bit-0 Digital Input 1 Off (0)/On (1) Bits read from Right to Left Bit-1 Digital Input 2 Off (0)/On (1)
Page 28
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus base 0 Modbus Value code address 5 digit address (Read/Write*) Description Note 3 (Read Only) 40001 Bit-0 Mask for SIPOD 1 Open (0)/Close (1) Bits read from Right to Left 6 &...
Page 29
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus Base 0 Modbus Value code address 5 digit address (Read/Write*) Description Note Bit-4 SIPOD 5 Open (0)/Close (1) Bit -5 SIPOD 6 Open (0)/Close (1) Bit-6 SIPOD 7 Open (0)/Close (1) Bit-7...
Page 32
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus base 0 Modbus Value code address 5 digit address (Read/Write*) Description Note Bit - 3 Mask for Digital Input 20 Off (0)/On (1) Bit - 4 Mask for Digital Input 21* Off (0)/On (1) Bit - 5...
Page 33
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus base 0 Modbus Value code address 5 digit address (Read/Write*) Description Note Bit - 3 Mask for Output Group (Zone) 4 Open (0)/Close (1) Bit - 4 Mask for Output Group (Zone) 5 Open (0)/Close (1) Bit - 5...
Page 34
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus Base 0 Modbus Value Code Address 5 digit address (Read/Write*) Description Note Bit - 8 Mask for Output Group (Zone) 57 Open (0)/Close (1) Bit - 9 Mask for Output Group (Zone) 58 Open (0)/Close (1) Bit - 10...
Page 35
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus Base 0 Modbus Value Description Note Code Address 5 digit address (Read/Write*) Bit - 15 Output Group (Zone) 48 Open (0)/Close (1) 40032 Bit - 0 Output Group (Zone) 49 Open (0)/Close (1) Bit - 1...
Page 36
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus base 0 Modbus Value code address 5 digit address (Read/Write*) Description Note 40063 SIPOD 23 - Status word (See “SIPOD Status”) (Read Only) 40064 SIPOD 24 - Status word (See “SIPOD Status”) (Read Only) 40665...
Page 37
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus Base 0 Modbus Value code address 5 digit address (Read/Write*) Description Note 40259 Output Group (Zone) defi nition 3 40260 Output Group (Zone) defi nition 4 40261 Output Group (Zone) defi...
Page 38
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus base 0 Modbus Value code Address 5 digit address (Read/Write*) Description Note 40312 Output Group (Zone) defi nition 56 40313 Output Group (Zone) defi nition 57 40314 Output Group (Zone) defi...
Page 39
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus base 0 Modbus Value code address 5 digit address (Read/Write*) Description Note 40365 Output Group (Zone) defi nition 109 40366 Output Group (Zone) defi nition 110 40367 Output Group (Zone) defi...
Page 40
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Function Modbus base 0 Modbus Value code address 5 digit address (Read/Write*) Description Note Bit 10-12 Not used 1-Single Pole, 2 - Two Pole, Bit 8-9 SIPOD Type 3 - Three Pole Bit 0-7...
Page 41
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Modbus base 0 Modbus Value Function code address 5 digit address (Read/Write*) Description Note 1528-1791 Reserved Digital Input 1 Type 1792 41793 (See “Input Type” page #) 1793 41794 Digital Input 2 Type...
Page 42
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Modbus base 0 Modbus Value Function code address 5 digit address (Read/Write*) Description Note 2059 42060 I/O Map for Digital Input 12 2060 42061 I/O Map for Digital Input 13 2061 42062 I/O Map for Digital Input 14...
Page 44
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Modbus base 0 Modbus Value Function code address 5 digit address (Read/Write*) Description Note Bit 0 - 7 Type of SIPOD 40 2836 42837 Bit 8 - 15 Type of SIPOD 41 Bit 0 - 7 Type of SIPOD 42...
Page 45
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Modbus base 0 Modbus Value Function code address 5 digit address (Read/Write*) Description Note 3337 43338 Override time SIPOD 10 3338 43339 Override time SIPOD 11 3339 43340 Override time SIPOD 12...
Page 46
Appendix C Modbus Coils, Discrete Inputs, Input Registers & Holding Registers Address Tables Holding Registers Modbus Base 0 Modbus Value Function code address 5 digit address (Read//Write*) Description Note 3600 43601 Logic Operation for Digital Input 17 3601 43602 Logic Operation for Digital Input 18 3602 43603 Logic Operation for Digital Input 19...
Page 47
Appendix D Dimming Instructions In i-3, Dimming can be configured in two terminal on the IO Board, based on the Note: The values 0 to 4095 correspond to different approaches. actual value received from this device (in 0 to 10 volts.
Page 48
Appendix D Dimming Instructions However, to be able to use this feature, the following registers need to be set. Analog Output Feed Settings for Step Dimming Register Function Set Register Value Value Function Definition Step Dimming Threshold Level Settings from Analog Output 1 Feed 41 or 42 Analog Input 1 (41) or Analog Input 2 (42)
Page 49
Appendix D Dimming Instructions In this configuration, while there is an Analog Input device connected to the TB6 terminal on the IO Board, based on the actual value received from this device (in the range of 0 to 4095), an Analog Output device connected to the TB5 terminal on the IO Board, can be controlled in such a way that a constant Analog Output can be maintained.
Page 50
Appendix E USB to RS485 Converter Driver Software Installation Instructions 1. On your Web browser, go to the following URL: http://www.ftdichip.com/Drivers/CDM/CDM20814_Setup.exe The following window opens 2. Click on “Save” to download the exe fi le “CDM20814_Setup.exe”. Save it in any folder of your choice. 3.
Page 51
Appendix E USB to RS485 Converter Driver Software Installation Instructions 5. Click on “Run.” 6. When the console window goes away, the driver is ready. 7. Plug in the USB-RS485 cable, and the driver will load. 8. To determine which COM port was allotted by the system for this USB-to-RS485 Converter;...
Page 52
Appendix E USB to RS485 Converter Driver Software Installation Instructions d. Click on the “Hardware tab; the following screen opens e. Click on “Device manager; the following screen opens:...
Page 53
Appendix E USB to RS485 Converter Driver Software Installation Instructions f. Press the “+” symbol to expand “Ports (COM & LPT)”, to see which virtual COM port is assigned to the USB-RS485 converter.
Page 54
Appendix E USB to RS485 Converter Driver Software Installation Instructions...
Page 55
Appendix F Recommended Input Devices Digital Inputs tested for compatibility with i-3 Model Momentary/ Number of Manufacturer number Maintained Type contacts sets Leviton 1754-ILA Maintained Mantained-Toggle-2 Wire Leviton 1754- ILI Maintained Mantained-Toggle-2 Wire Leviton 1754-ILW Maintained Mantained-Toggle-2 Wire Leviton 1754-T...
Page 56
Appendix F Recommended Input Devices Digital light sensors tested for compatibility with i-3 Model Momentary/ Number of Manufacturer number Maintained Type Indoor/outdoor contacts sets Line voltage, it requires an TORK 2001 Maintained Outdoor 1 Powered (120 VAC) interposing relay Line voltage, it requires an...
Norcross, GA 30092 For Technical Support: Call us at 1-800-333-7421 or visit www.usa.siemens.com/powerdistribution i-3 Web site: www.usa.siemens.com/i-3 For Nearest Sales Offi ce: Call us at 1-800-964-4114 or visit www.usa.siemens.com/i-3 Warranty Support and Customer Service: http://www3.sea.siemens.com/sales/salesoffi ces.html?rc=1 Contact local sales offi ce.