MC-UG509-00 1.2. PICTORIAL DIAGRAM NOTE: For general servicing, it is necessary to eliminate pinching of any wire during reassembly. After servicing any electrical component or electrical enclosure, the unit should be reassembled and checked for dielectric breakdown or current leakage.
Page 8
MC-UG509-00 2.2.2. Parts List (Nozzle Housing) Ref. No. Part No. Part Name & Description Quantity Remarks AC97ADDWZV07 LOWER BODY UNIT AC01CDDWZV07 WHEEL AC16CNXZ00 ROLLER SHAFT AC27ADDWZ000 LOWER PLATE AXTN4+10BFY SCREW SHIPPED 10 PER PACKAGE AC99QCYBZV06 WHEEL UNIT AC11ADDXZ000 FELT (LOWER)
MC-UG509-00 2.3. Packing Materials 2.3.1. Exploded View 2.3.2. Parts List (Packing Materials) Ref. No. Part No. Part Name & Description Quantity Remarks AC61ZDKVZ000 Packing Assembly Includes 1 and items a thru f AC01ZDKXZ000 Operating Instructions...
MC-UG509-00 3 REPLACEMENT INSTRUCTIONS 3.1. Lower Plate Replacement 3.1.1. Removal 1. Before servicing any parts, disconnect vacuum from electrical outlet. 2. Place paper under nozzle whenever lower plate is removed to protect floor. 3. Place handle in upright position and turn vacuum over to expose lower plate.
3.4.2. Installation the agitator tube. 1. Loop new belt (Panasonic Type UB8 only) around motor shaft and agitator pulley; see illustration for correct belt routing. 2. Reinstall slide arc into end cap slots, as outlined in the Agitator Assembly Replacement section.
MC-UG509-00 3. Once the carpet/bare floor pedal assembly is out it can be disassembled for parts replacement as shown in the Exploded View diagram. 3. Remove the three (3) screws that secure the handle release 3.6.2. Installation assembly to the nozzle housing.
MC-UG509-00 4 REPLACEMENT INSTRUCTIONS 4.1. Motor Replacement pinching of any wire during reassembly. After servicing any electrical component or electrical enclosure, the vacuum 4.1.1. Removal cleaner should be reassembly and checked for dielectric breakdown or current leakage. 1. Remove the dust cover.
MC-UG509-00 4.3. Power Cord / On-Off Switch 4.2.2. Installation Replacement 1. Install new bulb socket into motor case. 2. Connect yellow lead wire to fan motor. 4.3.1. Removal 3. Connect white lead wire from bulb socket, black lead wire 1. Remove the dust cover and switch cover to expose the from motor a wire nut.
MC-UG509-00 3. Ensure that the insulator packing is installed correctly. 4. Once left side has cleared, remove nozzle housing from motor shaft. 4.4.2. Installation 1. Fit the nozzle from the motor shaft side first, and rotate it into place on the dust container.