Page 3
GENERAL PRECAUTIONS REGARDING THE SERVICE FOR THIS EQUIPMENT The installation and service shall be done by a qualified service technician. 1. Transportation/Installation When transporting/installing the equipment, employ two persons and be sure to hold the positions as shown in the figure. The equipment is quite heavy, and weighs approximately 61 kg (134.51 lb.), therefore pay full attention when handling it.
Page 4
Be sure to handle/install them properly. If these parts are short-circuited and their functions become ineffective, they may result in fatal accidents such as explosion or burnout. Do not allow a short-circuit and do not use the parts not recommended by Toshiba TEC Corporation.
Page 5
“CAUTION. HOT”, “CAUTION. HIGH VOLTAGE”, “CAUTION. LASER BEAM”, etc. to see if there is any dirt on their surface and if they are properly stuck to the equipment. e-STUDIO206L/256/306 / 207L/25L/307 e-STUDIO356/456/506 / 357/457/507 [1] Certification label (For U.S.A and Canada) [2] Explanatory label [3] Identification label (For U.S.A, Canada and EU)
Page 6
ALLEGEMEINE SICHERHEITSMASSNAHMEN IN BEZUG AUF DIE WARTUNG FÜR DIESES GERÄT Die Installation und die Wartung sind von einem qualifizierten Service- Techniker durchzuführen. 1. Transport/Installation Zum Transportieren/Installieren des Gerätes werden 2 Personen benötigt. Nur an den in der Abbildung gezeigten Stellen tragen. Das Gerät ist sehr schwer und wiegt etwa 62.5 kg;...
Page 7
2. Allgemeine Sicherheitsmassnahmen in bezug auf die Wartung Während der Wartung das Gerät ausschalten und das Netzkabel herausziehen (ausser Wartung, die bei einem eingeschalteten Gerät, durchgeführt werden muss). Das Netzkabel herausziehen und den Bereich um die Steckerpole und die Steckdose die Umgebung in der Nähe von den Steckerzacken und der Steckdose wenigstens einmal im Jahr reinigen.
Page 8
Wenn diese Teile kurzgeschlossen und funktionsunfähig werden, kann dies zu schwerwiegenden Schäden, wie einer Explosion oder einem Abbrand, führen. Kurzschlüsse sind zu vermeiden, und es sind ausschließlich Teile zu verwenden, die von der Toshiba TEC Corporation empfohlen sind. 5. Warnetiketten Im Rahmen der Wartung unbedingt das Leistungsschild und die Etiketten mit Warnhinweisen überprüfen [z.
Page 9
6. Entsorgung des Geräts, der Verbrauchs- und Verpackungsmaterialien, alter Akkus und IC- RAMs In Bezug auf die Entsorgung und Wiederverwertung des Geräts, der Verbrauchs- und Verpackungsmaterialien, alter Akkus und IC-RAMs, einschließlich Lithiumakkus, sind die einschlägigen nationalen oder regionalen Vorschriften zu befolgen. Caution: Dispose of used batteries and IC-RAMs including lithium batteries according to this manual.
Page 10
• Laseremissionseinheit Diese Einheit besteht aus der Laserdiode, dem Fokussierungsobjektiv, der Blende und dem Zylinderobjektiv. Laserdiode Diese Laserdiode zeichnet sich durch eine geringe Regeldifferenz, eine kleine Laservariation und einen niedrigen Schwellenstrom aus. Die Blende der Laseremissionseinheit ist unter dem Fokussierobjektiv angeordnet, um die Form der Laserstrahlen in der primären und sekundären Scanrichtung festzulegen.
Operation of DC Output Circuits ..............3-84 3.18.3 Output Channel....................3-86 3.18.4 Fuse......................... 3-90 4. DISASSEMBLY AND REPLACEMENT................ 4-1 Disassembly and Replacement of Covers <e-STUDIO206L/256/306/356/456/506>..4-1 4.1.1 Front cover......................4-1 4.1.2 Front upper cover ....................4-1 4.1.3 Front lower cover ....................4-2 4.1.4...
Hard disk full error “H04” is displayed............8-316 8.5.3 Error code “M00” is displayed while updating firmware ......... 8-316 9. REPLACEMENT OF HDD/PC BOARDS ..............9-1 Installation and Replacement of PC boards <e-STUDIO206L/256/306/356/456/506>..9-1 9.1.1 System control PC board (SYS board) .............. 9-1 9.1.2 Hard disk (HDD) ....................
• The laser optical unit differs from the one used for e-STUDIO206L/256/306/356/456/506. • The attachment direction of the HDD differs from the one for e-STUDIO206L/256/306/356/456/506. e-STUDIO206L/256/306/356/456/506: Vertical e-STUDIO207L/257/307/357/457/507: Horizontal • The SLG board was removed since its function has been integrated into the SYS board.
Fixing method......Halogen lamp (2 pieces) <Halogen lamp (3 pieces)> Photosensor type ....OPC Original scanning sensor..Linear CCD sensor Scanning light source ....e-STUDIO206L/256/306/356/456/506: Xenon lamp / LED e-STUDIO207L/257/307/357/457/507: LED Reproduction ratio ....Actual ratio: 100±0.5% Zooming: 25 to 400% in increments of 1% (25 to 200% when using RADF) Resolution .......
Page 26
LG, LT, LT-R, ST-R, COMPUTER, 13"LG, 8.5" x 8.5" Acceptable paper weight 64 - 105 g/m (17 - 28 lb. Bond) Offset mechanism ....e-STUDIO206L/256/306 / 207L/257/307: No exclusive offset mechanism e-STUDIO356/456/506 / 357/457/507: Uses an exclusive offset mechanism Offsetting mechanism with movable exit roller (Shift amount: 30 mm, Stack height: 40 mm (250 sheets)) Interface ........
* When the tilt angle of the control panel is 7 to 84 degrees. 7 5 6 7 - 8 4 ° Fig. 2-1 Weight ........e-STUDIO206L/256/306: Approximately 58 kg (127.87 lb.) e-STUDIO356/456/506: Approximately 61 kg (134.48 lb.) e-STUDIO207L/257/307: Approximately 54.5 kg (120.17 lb.) e-STUDIO357/457/507: Approximately 56.5 kg (124.58 lb.) (include the developer material and drum) 2.1.2...
Page 29
Leading / trailing edges: 4.2±2.0 mm, Side edges: 4.2±2.0 mm (print) Multiple copying....... Up to 999 copies; Key in set numbers First copy time ......e-STUDIO206L / 207L: Approx. 4.7 sec. or less e-STUDIO256 / 257: Approx. 4.7 sec. or less e-STUDIO306 / 307: Approx.
After that, arithmetic operation is performed on the digital signal, which is then transmitted to the data writing section. e-STUDIO206L/256/306/356/456/506; Depending on the production period, the machine is equipped with a 4-line CCD or a 3-line CCD. Therefore, be sure to perform the appropriate service for the actually equipped CCD.
Page 94
Lens unit CCD driving PC board Fig. 3-31 6. Scanning section control PC board (SLG) (e-STUDIO206L/256/306/356/456/506) This is a board to perform the image correction, such as the shading correction and 3-line correction, and control the scan motor (M1). 7. System control PC board (SYS board) (e-STUDIO207L/257/307/357/457/507) This is a board to control the above SLG board (described in No.
Page 95
9. Lamp inverter board (INV) / LED board (LEDB) (e-STUDIO206L/256/306/356/456/506) Controls lighting of the exposure lamp (EXP). The control PC board is different depending on the light source. The xenon lamp is controlled by the lamp inverter board and the LED is controlled by the LED board.
Page 114
The electrical potential of the drum surface is fixed to a certain amount before the drum is charged. The number of the discharge LEDs for the e-STUDIO206L/256/306 / 207L/257/307 differs from that for the e-STUDIO356/456/506 / 357/457/507 because the discharging amount differs depending on the copy speed.
Page 117
[ 2 ] Recovered process unit mechanism The process unit of this equipment has two types; one is for the e-STUDIO206L/256/306 / 207L/257/ 307 and another is for the e-STUDIO356/456/506 / 357/457/507. The differences between two are shown below. Be sure not to install the process unit to a wrong model when replacing them because they are incompatible each other.
Page 120
Differences between e-STUDIO206L/256/306 / 207L/257/307 and e-STUDIO356/456/506 / 357/457/ e-STUDIO206L/256/306 / e-STUDIO356/456/506 / item 207L/257/307 357/457/507 Sub heater lamp Not installed Installed Pressure roller ø30(mm) ø35(mm) Connector For e-STUDIO206L/256/306 / For e-STUDIO356/456/506 / 207L/257/307 357/457/507 [ e-STUDIO206L/256/306 / 207L/257/307] [ e-STUDIO356/456/506 / 357/457/507] [ e-STUDIO206L/256/306 / 207L/257/307] [e-STUDIO356/456/506 / 357/457/507] Fig.
Page 121
(+) bias is applied to the pressure roller and the entrance guide. A sponge roller with a lower hardness is adopted for the pressure roller in this fuser unit to enable envelopes to pass through. The outside diameter of the pressure roller is ø30(mm) for e-STUDIO206L/256/306 / 207L/257/307 and ø35(mm) for e-STUDIO356/456/506 / 357/457/507.
Page 122
For e-STUDIO206L/256/306 / 207L/257/307, the sub heater lamp is not installed. The thermistors control the temperature of fuser roller and detect temperature abnormalities. If the temperature becomes excessively high, the thermostat is opened to stop the power supply to the heater lamps.
2 thermostats (front and center ones in the fuser unit) shut off the power supply to the heater lamps to protect the equipment. For e-STUDIO206L/256/306 / 207L/257/307, the sub heater lamp is not installed. Fuser unit Switching regulator...
3.16.1 General Description For e-STUDIO206L/256/306 / 207L/257/307, a sheet of paper with the toner fused on is transported to the inner tray or Automatic Duplexing Unit (ADU) by switchbacking. in the paper exit section. For e-STUDIO356/456/506 / 357/457/507, a sheet of paper with the toner fused on is transported to the inner tray, but the exit roller does not switchback.
Page 125
3.16.2 Functions 1. Exit motor (M10) The exit motor is a stepping motor which drives the exit roller. For e-STUDIO206L/256/306 / 207L/ 257/307, this motor rotates exit roller reversely to switchback when the paper is transported to the ADU. 2. Exit roller The exit roller transports the paper from the fuser unit to the inner tray.
Page 129
ADU. For e-STUDIO206L/256/306 / 207L/257/307, when the paper passed the exit sensor, the exit roller switchbacks to transport the paper into the ADU.
TRC (Triac) is driven by the heater control signal (HTR1ON/HTR2ON/HTRASTON) from the LGC board and then AC power is supplied to each heater lamp (center, side and sub) in the fuser unit. For e-STUDIO206L/256/306 / 207L/257/307, the sub heater lamp is not installed and the HTRASTON signal is not supplied.
Page 302
4.16.10 MJ-5005 (Offset tray) (e-STUDIO206L/256/306 / 207L/257/307) Turn the power OFF and unplug the power cable. Take off the tray. Tray Fig. 4-463 Remove 2 screws and take off the cover. Cover Fig. 4-464 Take off the right rear cover-1 and the right rear cover-2.
150,000 sheets • Values under “Replacement” indicate the replacement cycle for the e-STUDIO206L/256/306/ 356/456/506 / e-STUDIO207L/257/307/357/457/507. • The replacement cycle of the parts in the feeding section equals to the number of sheets fed from each paper source.
Fuser unit fuse For fuser unit 101-18 101-18 * “P-I” represents the page item in “e-STUDIO206L/256/306/356/456/506 Service Parts List” or “e- STUDIO207L/257/307/357/457/507 Service Parts List”. No.1-13, 15-17: Refer to “e-STUDIO206L/256/306/356/456/506 Service Parts List” or e- STUDIO207L/257/307/357/457/507. No.14: Refer to “MJ-1101 Service Parts List” or “MJ-1107 Service Parts List”.
456/506) Overhaul each equipment in the following timing. • e-STUDIO206L: When the number of output pages has reached 240,000 or 2.5 years have passed from the start of use (Whichever comes earlier) • e-STUDIO256: When the number of output pages has reached 300,000 or 2.5 years have passed from the start of use (Whichever comes earlier) •...
If a problem continues even after performing all troubleshooting and technical tips, report the problem to the appropriate Toshiba service center along with the following information. This information will help the service center understand your problem and take quick action to find the solution.
Page 691
Parts to be replaced Remark Lens unit SYS board Harnesses [C270] Carriage home position sensor not going OFF within a specified time (e-STUDIO206L/ 256/306/356/456/506) Classification Error content Scanning system related service The carriage does not shift from its home position in a specified call period of time.
Page 694
[C280] Carriage home position sensor not going ON within a specified time (e-STUDIO206L/256/ 306/356/456/506) Classification Error content Scanning system related service The carriage does not reach to its home position in a specified call period of time. Remove the original glass and move the carriages to the paper feeding side. Turn ON the power and check the following items.
8.3.20 Offset tray related service call [CDF0] Initialize error of the offset tray (e-STUDIO206L/256/306 / 207L/257/307) Classification Contents Offset tray related service call Initialize error of the offset tray Check Item Measure OCT motor 1. Check if each connector between the OCT motor and OCT OCT board board (CN261) is disconnected.
REPLACEMENT OF HDD/PC BOARDS Installation and Replacement of PC boards <e-STUDIO206L/ 256/306/356/456/506> Notes: • When the PC board/HDD is replaced, refer to the respective Notes and Cautions of “Replacement of PC board and HDD” in P. 9-16 "9.3 Precautions and Procedures for Replacing PC Boards and HDD".
P. 9-28 "9.3.5 Procedures when replacing the LGC board" • To replace the SLG board, see the following procedure. P. 9-29 "9.3.7 Procedures when replacing the SLG board (e-STUDIO206L/256/306/356/456/ 506)" • To replace the SRAM board, see the following procedures.
If you cannot start up with the setting mode (08), begin from step (3). Turn the power OFF. Remove the LGC board. P. 9-3 "9.1.3 LGC board (e-STUDIO206L/256/306)" P. 9-4 "9.1.4 LGC board (e-STUDIO356/456/506)" P. 9-10 "9.2.3 LGC board (e-STUDIO207L/257/307)"...
Start up with the Setting Mode (08). Copy the data in the EEPROM to SRAM (08-4582). Turn the power OFF. 9.3.7 Procedures when replacing the SLG board (e-STUDIO206L/256/ 306/356/456/506) Notes: Before replacing the SLG board, perform the following procedure. P. 9-16 "9.3.1 Precautions when replacing PC boards"...
Page 908
If there is no more licenses to be returned, press the [CLOSE] button, and then turn the power OFF. [C] Replace SRAM board Confirm that the power is turned OFF. e-STUDIO206L/256/306/356/456/506: If the FAX unit (GD-1250) is installed, disconnect the connector (CN134). e-STUDIO207L/257/307/357/457/507: If the FAX unit (GD-1350) is installed, disconnect the USB connector (CN117).
Page 909
When the back-up file is restored, do not perform HDD partition creation (Format HDD) before the normal start-up. (11) e-STUDIO206L/256/306/356/456/506: If the FAX unit (GD-1250) is installed, connect the connector (CN134). (12) e-STUDIO207L/257/307/357/457/507: If the FAX unit (GD-1350) is installed, connect the USB connector (CN117).