Page 1
INTERIOR DOME CAMERA INSTRUCTION MANUAL SID-41C/21C SERIES SAMSUNG CCD CAMERA...
Page 2
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK), NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage"...
Page 3
Thank you for purchasing a SAMSUNG CCD CAMERA. Before operating the camera, confirm the camera model and proper input power voltage. In order that you can understand this manual thoroughly, we'll introduce our model description. SID-41C Model Series (410,000 Pixels)
Features High Resolution Powerful Back Light Compensation The horizontal resolution of 480 TV lines The BLC technology allows the camera to can be achieved by using a high density obtain the clear picture, the finest detail CCD having effective 410,000 pixels, and perfect light contrast al though there which provides clean, noiseless and is strong light back of the subject.
Precautions Do not install the camera in extreme Do not install or use the camera in an temperature conditions. environment where the humidity is high. It can cause the image quality to be poor. Do use the camera under conditions where temperatures are within -10 C to 50 C.
Page 7
Never keep the camera face to strong Do not expose the camera to rain or light directly. spill beverage on it. If it gets wet, wipe it dry immediately. Liquids can contain minerals that corrode the electronic components. It can damage the CCD. Do not touch the front glass of the camera.
Getting to Know Your Camera Front (SID-41CVA Model) Tilt Adjustment You can adjust up and down the camera(30 ~90 ). Focal Length Adjustment Lever After Adjusting Focal Length by Pan Adjustment lever, fix it. You can rotate the lens from 0 to 340 Zoom Adjustment Lever After Adjusting Zoom position by...
Page 9
Front (SID-41CV/21CV Model) Tilt Adjustment You can adjust up and down the camera(30 ~90 ). Focal Length Adjustment Lever After Adjusting Focal Length by lever, fix it. Pan Adjustment You can rotate the lens from Zoom Adjustment 0 to 340 Lever After Adjusting Zoom position by lever, fix it.
Installation Installing Camera Fix the Bracket to suitable position where the camera will be installed. After inserting the Bracket pin to camera hole, rotate the camera right. After adjusting the camera, cover the Dome-Cover. BRACKET BRACKET PIN BRACKET PIN Screw Screw Hole Hole...
Connection to Monitor Connect the VIDEO-OUT jack to the VIDEO-IN jack of monitor. As a connecting method varies according to instruments, refer to the manual supplied with the instrument. Connect the cable after power is turned off. Set the 75 /Hi-Z selection switch. If it is a intermediate device, switch it to Hi-z and if it is final device, switch it to 75 .
Configuration of Dip-Switches Use the DIP switches inside of the camera for selecting functions. (SID-41 Series) (SID-21 Series) Default setting White Balance Control (ATW/AWC) Select the desired control mode using ATW/AWC switch. ATW(Auto Tracing White balance) : The camera automatically control the white balance in any environment.
Backlight Compensation (BLC) Switch it to BLC to obtain the clear picture, the finest detail and perfect light contrast althongh there is strong backlight. BLC ON : When the image is in front of strong background lighting, your camera allows you to get the clear image. BLC OFF : Deactivate BLC control feature.
Flickerless (FL) (SID-41 Series Only) Select the desired control mode using Flicker switch. FL ON : You can select FL (Flickerless) ON. FL OFF : You can select FL (Flickerless) OFF. (SID-41 Series) NOTE In case of selecting FL OFF, you can obtain the well-brightened image by the built-in Iris Lens (SID-41CVA).
Zoom (SID-41 Series Only) If you choose 'Zoom' function, you can obtain altwice enlarged image. (2X Digital Zoom) Zoom ON : Activate Zoom feature. Zoom OFF : Deactivate Zoom feature. (SID-41 Series) • When Digital zoom activated, it can cause the image quality to be NOTE poor Brightness Control...
Panning & Tilting Control You can adjust the Panning and Tilting angle freely. (Panning angle: 0 to 340 , Tilting angle: 30 ~90 ) Adjustment Panning angle After attaching the dome camera to ceiling, adjust the panning angle for better monitoring area by rotating the Pan Base. The panning angle can be adjusted to 0 from 340 freely.
Zooming Control (SID-41CVA/41CV/21CV) Adjust the magnification of monitoring pictures by rotate Zoom Adjustment Lever. TELE To zoom in, rotate the Zoom Adjustment lever clockwise. WIDE To zoom out, rotate the Zoom Adjustment lever counterclockwise. WIDE Zoom Adjustment Lever (T W) TELE After Adjusting Zoom position by lever, fix it.
Troubleshooting If you have trouble operating your camera, refer to the following. If the guidelines do not enable you to solve the problem, contact an authorized technician. The image on the screen is dim. • Check if the lens are stained. If dirty, clean the lens with soft, clean cloth. •...
2003 Conformance to EN 50081-1 EN 50130-4 We, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s). Manufacturer SAMSUNG TECHWIN CO., LTD Legal Representative in Europe Signature Signature Full Name YOUNG TAEK SON Full Name...
Page 25
[ SALES NETWORK ] SAMSUNG TECHWIN CO., LTD SAMSUNG OPTO-ELECTRONICS AMERICA INC. 40 SEAVIEW DIRVE, SECAUCUS N.J OPTICS & DIGITAL IMAGING DIV. 07094, U.S.A. 145-3, SANGDAEWON 1-DONG, JUNGWON-GU, SUNGNAM, KYUNGKI-DO, KOREA TEL : 201-902-0347 462-121 FAX : 201-902-9342 TEL : 82 -31-740 - 8137~41 FAX: 82 -31-740 - 8145 www.samsungcctv.com...