PROLIANT 8500 PENTIUM III XEON
Version 1.0 – 8/12/1999
Assumptions
• Proliant 8500 Pentium III Xeon minimum system requirements have been met (see Appendix A)
Refer to the Proliant 8500 Pentium III Xeon "Maintenance and Service Guide", "Setup and Install Guide",
"Illustrated Parts Catalogue". When available
TABLE OF CONTENT
SECTION
TOPIC
1
Status Indictors
2
Switches
3
Troubleshooting
4
Troubleshooting Tips
5
Appendix A: Minimum System Configuration
Appendix B: Power up sequence
Appendix C: Interlock Chain Block Diagram
Section 1
STATUS INDICTORS:
• Integrated Management Display (IMD): Liquid Crystal Display (LCD)
Located on front of system, used to monitor progress during POST and to display cautions and critical
error messages.
• POWER-ON LED:
Located on the front panel beside power switch. When pushed, green indicates good +5V output from
power supply. Flashing amber indicates a system fault.
• POWER SUPPLY LEDs:
Located on rear of unit next to AC power input.
Power Supply LED Table
Table 1 –1: Power supplies LEDs indictor definitions
Top LED
Green
(Status)
Green/Amber
flashing
Green flashing
Amber flashing
Amber
Off
Bottom LED
Green
(AC Power)
Off
TROUBLESHOOTING GUIDELINE
No fault detected in this power supply
Power supply failed to restart after a prolonged fault
Power supply will start within 20 seconds or software shutdown
(software shutdown mode won' t restart unless power switch is
cycled).
Failed self test
Fault detected in this power supply
System in standby mode or interlock(s) disabled
AC power is connected to this power supply
No AC power connected to this supply
1