Chapter 2: Useful Features The details of system BIOS settings, RAID Configuration Utility, and EXPRESSBUILDER Chapter 3: Appendix Error messages and Windows Event Logs Other manuals The details of NEC ESMPRO, Universal RAID Utility, and other features Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Problem at Starting OS ........................33 Problem of Windows STOP Error ....................34 Problem of RAID System ......................... 35 Problem of Internal Devices and Other Hardware ................36 Problem of OS ..........................38 Problem of EXPRESSBUILDER on Windows .................. 39 Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 4
Flash FDD ..............................123 Precautions ............................ 123 3.1.1 Compensation for recorded data ..................123 3.1.2 Handling Flash FDD ......................123 3.1.3 Precautions when using EXPRESSBUILDER ..............123 Power Control Feature ..........................124 Supported OS ..........................124 Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 5
Utilities in EXPRESSBUILDER ...................... 178 EXPRESSBUILDER Command Line Interface ................178 EXPRESSSCOPE Engine 3 ........................179 NEC ESMPRO ............................180 NEC ESMPRO ServerAgentService (for Windows) ............... 180 NEC ESMPRO Manager ........................ 181 NEC ESMPRO Agent Extension ....................182 Server Configuration Utility ......................182 NEC ExpressUpdate Agent ......................
Term indicating a degree of danger attention WARNING Use only the specified outlet Use a grounded outlet with the specified voltage. Use of an improper power source may cause a fire or a power leak. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Unless otherwise stated, hard disk drive described in this document refers to the following. Hard disk drive (HDD) Solid state drive (SSD) Removable media Unless otherwise stated, removable media described in this document refers to the following. USB flash drive Flash FDD Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Windows Server 2012 R2 Datacenter Windows Server 2012 R2 Foundation Windows Server 2012 Standard Windows Server 2012 Windows Server 2012 Datacenter Windows Server 2008 R2 Standard Windows Server 2008 R2 Windows Server 2008 R2 Enterprise Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Trademarks Trademarks EXPRESSSCOPE is a registered trademark of NEC Corporation. Microsoft, Windows, and Windows Server are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Intel, Pentium, and Xeon are registered trademarks of Intel Corporation of the United States.
"This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit. (http://www.openssl.org/)" The names "OpenSSL Toolkit" and "OpenSSL Project" must not be used to endorse or promote products derived from this software without prior written permission. For written permission, please contact openssl-core@openssl.org. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 11
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
This document is subject to change at any time without notice. Do not make copies or alter the document content without permission from NEC Corporation. If you have any concerns, or discover errors or omissions in this document, contact your sales representative.
Describes how to reset or clear the server. See this section if the server is not working or if you want to restore the BIOS settings to the factory settings. 8. System Diagnostics Describes the system diagnostics of the server. 9. Offline Tools Describes tools for preventive maintenance of the server. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
2. Power off the server (POWER LED goes off). 3. Unplug the power cord of the server from the power outlet. 4. Disconnect all the cables from the server. 5. Pack the server securely to protect from damage, shock, and vibration. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 15
If the server is suddenly moved from a cold place to a warm place, condensation will occur and cause failures. Wait for a sufficient period of time before using the server and other components. Note Adjust the system clock before operating after relocating or storing the server. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
We recommend you to apply the latest update always. NEC corporate site: http://www.nec.com/ [Support & Downloads] NEC also provides ExpressUpdate that helps you to download and install updates that must be applied to BIOS and FW of the server. Tips NEC recommends that you back up data before applying the latest update.
For details, see Safety precautions and Regulatory Notices. Do not disassemble, repair, or alter the server. Disconnect the power plug before cleaning the server. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
POWER LED is off. An optical mouse does not work properly if the lens area is not clean. Wipe the sensor with a dry cloth to remove any dirt or dust. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
User Support Before getting after-sales service, check the contents of the warranty and service. Maintenance Services Service representatives from NEC subsidiary companies or companies authorized by NEC provide maintenance services. For the services, contact your sales representative. Before Asking for Repair If you think that a failure occurred, follow the steps below: 1.
If a STOP error, system error, or stall occurs, restart the system and then follow the steps below. 4.1.1 Windows Server 2016 Right-click the left bottom of screen, and click Event Viewer from the menu displayed. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 21
Click Save All Events As from Action menu. Type the file name of the archived log in File name. Select the type of the log file you want to save in Save as type, and then click Save. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Click Settings on Charms Bar. To go to the step 4, you can directly choose Event Viewer by right-clicking on the lower left corner of the screen. Charms Right-click menu Click Control Panel from Settings. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 23
Click Save All Events As from Action menu. Type the file name of the log file in File name. Select the type of the log file you want to save in Save as type, and then click Save. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Click Save All Event As from Action menu. Type the file name of the log file in File name. Select the type of the log file you want to save in Save as type, and then click Save. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Right-click the left bottom of screen, and click Run from the menu displayed. Type msinfo32.exe, and then press <Enter> key. System Information starts. Click Export from File menu. Type a file name to save in File Name, and then Click Save. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Windows Server 2008 R2 Click Run from Start menu. Type msinfo32.exe in Open, and then click OK. System Information starts. Click Export from Files menu. Type a file name to save in File Name, and then Click Save. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Consult with your sales representative before dumping the memory. Dumping the memory while the server is in operating normally will affect the system operation. Important Do not reset during dumping memory or restarting the server even if the message of virtual memory shortage appears. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Is memory installed correctly? Check if memory is installed correctly. Is the memory size large? The memory check may take longer than usual if the installed memory size is large. Wait for a while. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Error [Message ID:Z3002]: Failed to detect a DVD drive or a flash drive. Action: Check if hardware is properly connected. Error [Message ID:Z3003]: Failed to read a file. Action: Check if DVD is damaged or not. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 30
EXPRESSBUILDER cannot start if the logical drives are not sequential (for example, the server has only LD#0 and LD#2, and LD#1 is not existed). In order to fix to the sequential drive number, delete the logical drives by using Universal RAID Utility or RAID Offline Tool, and try again. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
UEFI GUID Partition Table (GPT) Legacy BIOS Master Boot Record (MBR) For example, in UEFI environment, if the MBR formatted hard disk drive is specified for installation destination, the message as shown below is displayed. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 32
When Windows Server 2008 R2 is installed while several disks are connected, the system partition and the boot partition (100 MB) are created in another disk For details, refer to the website below. http://support.microsoft.com/kb/2530901/ja (Japanese text only) Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Check the restrictions of PCI slots on the server and then install the RAID controller to the correct slot. Are hard disk drives properly installed? Install the hard disk drive to the RAID controller properly. Is SAS cable connected to hard disk drive correctly? Connect the SAS cable properly. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Problem of Windows STOP Error Unable to turn the power OFF at the blue screen (STOP error screen) Continue to press the power switch for at least four seconds to turn off the server. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
DISK LED flashes frequently even while the hard disk drive is not accessed. When Patrol Read is running, the DISK LED flashes even if the hard disk drive is not being accessed. If SATA hard disk drive is used, the DISK LED may stay on. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Unable to access the hard disk drive Is the hard disk drive supported by the server? Operation of any device that is not authorized by NEC is not supported. Is the hard disk drive properly installed? ...
Page 37
See Chapter 2 (1. System BIOS) for details. Advanced → USB Configuration → XHCI Hand-off → Disabled Select Enabled for XHCI Hand-off after System Recovery Options finished. Advanced → USB Configuration → XHCI Hand-off → Enabled Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Although there may be RX dropped packets when the LAN is received multicast frames, there is no operational problem. LAN adopter port1 name is appeared as "Ethernet" in the system on Windows Server 2012 R2 It is not a problem in operating the system. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Click Cancel to close the window. If you accidentally format it, you can recover by performing the Update command again. The following message appears on the right bottom of screen Device driver software was not successfully installed Ignore the message. The message will automatically disappear. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
ESMPRO ServerAgentService Installation Guide (Windows)" in EXPRESSBUILDER. NEC ESMPRO Manager For details of NEC ESMPRO Manager, see "NEC ESMPRO Manager Installation Guide" in EXPRESSBUILDER or its help. 5.11 Problem of Optical Disk Drive Unable to access or play a CD/DVD ...
The value of memory throttling remains [0%] This server does not support the memory throttling feature. The information of the memory throttling does not change from [0%] in the EXPRESSSCOPE Engine 3, NEC ESMPRO Manager and Server Configuration Utility Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
The D: means the optical disk drive in the command below. drvload D:\016\win\winnt\drivers\05_system\1_af_04\drivers\win7\x64\iusb3hub.inf drvload D:\016\win\winnt\drivers\05_system\1_af_04\drivers\win7\x64\iusb3xhc.inf 4. To exit the command prompt, type the following at the command prompt and press <Enter>. exit The installation is now complete. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Do not shut down, restart the server, or perform any switch operation after pressing BMC Reset Switch for at least two minutes. Tips BMC RESET Switch only resets BMC and does not restart the server. T110i-S BMC RESET Switch Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 44
Chapter 1 Maintenance 7. Resetting and Clearing the Server R110i-1 3.5-inch Hard Disk Drive model BMC RESET Switch 2.5-inch Hard Disk Drive model BMC RESET Switch T110i BMC RESET Switch Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
(Keep pressing for at least four seconds) R110i-1 2.5-inch Hard Disk Drive model POWER Switch (Keep pressing for at least four seconds) 3.5-inch Hard Disk Drive model POWER Switch (Keep pressing for at least four seconds) Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 46
Chapter 1 Maintenance 7. Resetting and Clearing the Server T110i POWER Switch (Keep pressing for at least four seconds) Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Do not change any other jumper switches. Any change will cause the server to fail or malfunction. Clear NVRAM Jumper (J_CLRCMOS) 3 2 1 Clear Keep (factory setting) Clear Password Jumper (J_PASSWORD) 3 2 1 Clear Keep (factory setting) Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 48
6. Press <F2> key to start BIOS Setup Utility, and then run Load Setup Defaults from Save & Exit menu. The server will restart once before the OS starts. Tips After this operation, system may restart once before the OS is started. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 49
ERROR 8007: SETUP Menu Password cleared by Jumper. Press <F1> to resume, <F2> to Setup 5. Turn off the power and return the jumper switch to Keep by the same manner. 6. Reassemble the server. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Hard disk drive Important To avoid affecting a network and storage system, disconnect a LAN cable, Fibre Channel, NEC Storage, and other external storage before running System Diagnostics. Tips No data is written on the disk when checking the hard disk drives.
Page 51
“Abnormal End” appears in the result on the right side. Move the cursor to the test that detected the error, and press <Enter> key. Take notes about the error message that has been output to the Detail Information screen and contact your sales representative. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 52
To save it, connect FAT formatted removable media, and then choose Save(F). <Option> Optional features can be used from this menu. <Reboot> Restarts the server. 5. Choose Reboot in Enduser Menu. The server will restart. System Diagnostics is now completed. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
3. Keyboard Selection Menu appears after POST completion. The following menu appears after choosing a keyboard type. Off-line TOOL MENU Maintenance Utility Server Configuration Utility Exit 4. Choose a feature from the menu. See 9.2 Features of Offline Tools for more information. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Off-line Maintenance Utility is started when Maintenance Utility is chosen. Off-line Maintenance Utility is used for preventive maintenance and failure analysis for the server. If you are unable to start NEC ESMPRO due to a failure, Off-line Maintenance Utility can be used to check the cause of the failure.
You can also control Offline Tools remotely by using BIOS Console Redirection. 9.3.2 Preparation Enable the remote management feature of EXPRESSSCOPE Engine 3 in advance to check the hardware error during console-less operation. See "EXPRESSSCOPE Engine 3 User's Guide" or NEC ESMPRO Manager online help. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Describes the EXPRESSBUILDER attached to the server. 7. EXPRESSSCOPE Engine 3 Describes EXPRESSSCOPE Engine 3. 8. NEC ESMPRO Describes NEC ESMPRO used to manage and monitor the server. 9. NEC Product Info Collection Utility Describes the NEC Product Info Collection Utility. 10. Ezclct Viewer Describes Ezclct Viewer.
Page 57
Chapter 2 Useful Features 13. Express Report Service (MG) Describes about Express Report Service(MG). Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Advanced menu Security menu Server menu Boot menu Save & Exit menu These menus have several submenus for configuring. 1.2.1 Main When you start SETUP, the Main menu appears first. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 59
System Date WWW MM/DD/YYYY Sets the system date. System Time HH:MM:SS Sets the system time ]: Factory settings Tips Make sure that the date and time are correct. Using a time server (NTP server) is recommended. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Advanced menu appears when the cursor is moved to Advanced. For the menus that show a “ ” to their left, press <Enter> key to display its submenu, and then change the settings. When Boot Mode is UEFI: When Boot Mode is Legacy: Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 61
The selectable number of cores depends on processor installed. Hyper-Threading Disabled Enables or disables the feature to [Enabled] simultaneously execute two threads in a single core. This option is displayed only when the installed processor supports this feature. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 62
Installation Guide, and determine whether this feature is enabled or disabled according to description in "Before Starting Setup" appropriate to your OS. ]: Factory settings Processor Information submenu For details about the options, see the table on the next page. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 63
Intel 64 architecture. Hyper-Threading (display only) Displays Supported when processor 1 supports Hyper-Threading Technology feature. ]: Factory setting Processor Power Management submenu For details about the options, see the table on the next page. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 64
SW_ANY Hardware P-State [Disabled] Enables or disables the Hardware P-State feature of a processor. You do not need to Enabled change this option for the OS that does not support this feature. ]: Factory settings Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 65
Specifies the upper limit of the memory frequency. The frequency may be lower than 1333 MHz the specified value depending on the memory 1600 MHz configuration. 1866 MHz 2133 MHz 2400 MHz ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 66
The list below shows the meanings of the other states. Disabled: The memory has failed Not Present: No memory is installed Error: Forced memory startup ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 67
Specify completion timeout time for PCIe devices. 16 msec to 55 msec 65 msec to 210 msec [260 msec to 900 msec] 1 sec to 3.5 sec 4 sec to 13 sec 17 sec to 64 sec ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 68
Note For a RAID controller, LAN adapter (network boot), or Fibre Channel controller, if no hard disk drive on which an OS is installed is connected, set the option ROM for that slot to Disabled. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 69
Specifies the upper limit of the link speed for the PCI PCI1B Slot Link Speed Limit 5.0 GT/s slots in the range specified in Target Link Speed Limit PCI1C Slot Link Speed Limit [8.0 GT/s] (Express5800/R110i) ]: Factory settings Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 70
]: Factory setting Tips Use scheduled running feature or remote batch feature of NEC ESMPRO Manager to operate power supply at specified date and time. You can use these features with Wake On RTC Alarm setting disabled. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 71
Hard Disk Drive Pre-Delay [Disable] Specifies delay time before HDD is accessed 3 Seconds during POST. 6 Seconds 9 Seconds 12 Seconds 15 Seconds 21 Seconds 30 Seconds ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 72
Displays the devices connected to each port. Not Present means that no device is SATA Port1 connected to the port. SATA Port2 SATA Port3 SATA Port4 SATA Port5 SATA Port6 SATA Port7 ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 73
Specifies the time to wait when Control, Bulk, 5 sec or Interrupt Transfer Command is issued to a 10 sec USB controller. [20 sec] Disabled XHCI Hand-off Enables or disables the XHCI Hand-off [Enabled] feature. ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 74
On BIOS Redirection Port, choose Serial Port A or Serial Port B and then press <Enter> key to display the menu screen shown below. For details about the options, see the table on the next page. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 75
Specifies stop bits. Flow Control None Specifies the flow control method. [Hardware RTS/CTS] Continue C.R. after POST Disabled Enables or disables the feature to continue [Enabled] console redirection after completion of POST. ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 76
PXE Configuration Network Mode Disabled Specify the PXE network mode. [IPv4] IPv6 Media Detect Count [1]-50 Specify the number of times trying to detect media at PXE connection. iSCSI Configuration ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 77
223 The menu items below can be selected when "iSCSI Initiator Name" is specified. Add an Attempt Attempt [XX] Delete Attempts Change Attempt Order ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 78
<1> Add an Attempt submenu Note A MAC address is displayed when the onboard LAN controller or the UEFI driver for the PCI device is loaded. Option Parameter Description MAC [XX:XX:XX:XX:XX:XX] ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 79
[Disabled] Get Target info via DHCP Enable or disable the feature to obtain Enabled information of the target device via the DHCP server. This item is not displayed when "Disabled" is selected for Enable DHCP. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 80
This item is displayed when "CHAP" is selected for Authentication Type and "Mutual" is selected for CHAP Type. Save Changes Save the current settings. Back to Previous Page Return to the iSCSI Configuration submenu. ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 81
Commit Changes and Exit Save the current setting and return to the iSCSI Configuration submenu. Discard Changes and Exit Discard the current setting and return to the iSCSI Configuration submenu. ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 82
Commit Changes and Exit Save the current setting and return to the iSCSI Configuration submenu. Discard Changes and Exit Discard the current setting and return to the iSCSI Configuration submenu. ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 83
(UEFI Driver Name) controller or a UEFI driver for a PCI device is loaded. The on-screen menu depends on the specified UEFI driver. VLAN Configuration (MAC:XXXXXXXXXXXX) Driver Health ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 84
Specify VLAN Priority. Add VLAN Add VLAN. Configured VLAN List - [Disabled] Set VLAN to be deleted to [Enabled]. VLAN ID: [x], Priority:[x] Enabled Remove VLAN Delete the specified VLAN ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 85
(UEFI Driver Name) (display only) This item is displayed when the onboard LAN controller or a UEFI driver for a PCI device is loaded, and the UEFI driver supports the Driver Health Protocol. ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Do not set any password before installing the OS. If you have forgotten the password, see Chapter 1 (7. Resetting and Clearing the Server) to clear password. For details about the options, see the table on the next page. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 87
This item can be selected only when "Boot Mode" is set to "UEFI". Trusted Computing This option is displayed only when the optional TPM kit is installed. This option becomes available after Administrator Password is set ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 88
We recommend that you set “Administrator Password” to enable “Secure Boot”. Tips When “Secure Boot” is enabled, the UEFI driver of the option card needs to be signed by the Microsoft key to have the option card recognized as a bootable device. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 89
Display the status of Authorized Signatures (DB). Also register/delete DB. Forbidden Signatures Display the status of Forbidden Signatures (DBX). Also register/delete DBX. Authorized Timestamps Display the status of Authorized Timestamps (DBT). Also register/delete DBT. ]: Factory setting Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 90
1. System BIOS (2) Trusted Computing submenu On Security, choose Trusted Computing and then press <Enter> key to display the menu screen shown below. If you enable TPM Support, enable TPM State, the following menu screen appears. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 91
"TPM Support" is "Enabled". Intel(R) TXT Configuration TXT Support [Disabled] Enables or disables the Intel Trusted Enabled Execution Technology feature. This option can be selected when VT-x, VT-d, and TPM State are set to Enabled. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 92
Enables or disables Intel Virtualization [Enabled] Technology for Directed processor feature. VT-d Disabled Enables or disables Intel Virtualization [Enabled] Technology for Directed I/O feature. This option is displayed only when the installed processor supports this feature. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Boot Monitoring Enables or disables the boot monitoring 5-60 minutes feature and specifies the timeout setting. To use this feature, install NEC ESMPRO ServerAgentService on Windows. If starting up an OS on which it is not installed, disable this feature.
Page 94
Specifies whether to use Command Line Enabled Interface (CLI). Enabled : SETUP is run by CLI instead of the menu operation. To switch back to the menu operation, set this option to Disabled on CLI. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 95
Displays the revision of the sensor data record. NM Firmware Version (display only) Displays the firmware version of Intel Node Manager Descriptor Revision (display only) Displays the Descriptor revision. Chipset Revision (display only) Displays the chipset revision. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 96
If this option is enabled, the AC-LINK setting is fixed to Power On and cannot be changed. Enables or disables cold redundancy. Cold Redundant Mode [Disabled] This option is displayed only when using redundant (Express5800/T110i, T110i-S) Enabled power supply. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 97
* Continue pressing the POWER switch for at least 4 seconds to forcibly turn off the power. If an uninterruptible power supply (UPS) is used for automatic operation, set the Tips AC-LINK to Power On. AC-LINK option becomes valid when next time POST is running. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Specifies whether to display the logo during POST. [Enabled] Disabled : the results of POST execution are displayed instead of the NEC logo after the power is turned on. If BIOS Redirection Port is enabled, this option is always disabled.
Page 99
Priorities of each device type. (3) Case when a bootable device is demounted If a bootable device is demounted from this machine, the subject device is deleted from the Priorities of each device type. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 100
If Boot Mode is set to "Legacy", HDD Priorities shows the model number of the hard disk drive. Change bootable devices from SETUP instead of the bcdedit command of Windows and efibootmgr command of Linux. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
The values of iSCSI Configuration submenu and UEFI Driver Configuration submenu do not return to the default value. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
2. When you select a type of keyboard that is connected to the server, the Off-line TOOL MENU appears. Off-line TOOL menu 3. Selecting Server Configuration Utility in Off-line TOOL MENU starts Server Configuration Utility. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 103
Views or sets information concerning Battery when the server is the Battery model. For details, see Chapter 2 (2.7 Battery Configuration). (d) Help Opens help screen of Server Configuration Utility. (e) Return to the previous menu Exits Server Configuration Utility, and return to Off-line TOOL MENU. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Initializes BMC configurations to restore the default settings. For details, see Chapter 2 (2.6 Initializing Configuration). (e) Help Opens help screen of EXPRESSSCOPE Engine 3. Return to the previous menu Exits EXPRESSSCOPE Engine 3, and return to Server Configuration Utility menu. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
For details, see Chapter 2 (2.3.4 SNMP Alert). (e) System Operation Sets parameters for remote KVM console and remote media. For details, see Chapter 2 (2.3.5 System Operation). Miscellaneous Sets various features of BMC. For details, see Chapter 2 (2.3.7 Miscellaneous). Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Dynamic DNS Determine whether to enable/disable of Dynamic DNS. Disable DNS Server Specify the DNS Server. 0.0.0.0 Host Name Specify the Host Name. Blank Domain Name Specify the Domain Name. Blank Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 107
*11: Port number can be specified only when the relevant port is set to "Enable". The port number must be unique. *12: Can be specified only when IPv6 is set to "Enable". *13: Displayed only when "Dynamic" is specified for Address Assignment Mode. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Specify IP address of Domain Controller Server 3. Blank Active Directory (Group) Group Name Specify group name of Active Directory. Blank Group Domain Specify group domain of Active Directory. Blank Privilege Specify privilege of group of Active Directory. Administrator Administrator Operator User Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 109
*12: Characters in the range between 4 and 62 including alphanumeric, hyphen, underscore, period, comma, and equal sign can be used. *13: Alphanumeric characters in the range between 4 and 31 excluding ", #, and \ can be used. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
*6 *7 LOGIN Select Enable/Disable of LOGIN authentication. Enable *6 *7 PLAIN Select Enable/Disable of PLAIN authentication. Enable *6 *8 User Name Specify the SMTP User Name. Blank *6 *9 Password Specify the SMTP Password. Blank Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 111
Up to 19 alphanumeric characters can be used excluding " " blank, ",?, =, <, >, #, and \. *10: Be sure to perform Alert Test after all the parameters are configured appropriately. Alert feature may fail depending on configuration made for network or alert receiver. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Can be specified only when each Alert Receiver is set to "Enable". Be sure to perform Alert Test after all the parameters are configured appropriately. Alert feature may fail depending on configuration made for network or alert receiver. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
(Remote CD/DVD port number + 2) (Encryption) Remote FD Display the port number of remote FD when encryption is enabled. (Remote – CD/DVD port number + 3) (Encryption) Port numbers must be the unique one. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
(in seconds) depends on system. system value Shutdown System Enable or disable the feature to shutdown the system when power Disable consumption exceeds the time specified in Correction time limit. Non- Aggressive Enable or disable Non-Aggressive Mode. Disable Mode Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 115
If the value specified for Power Threshold (Pa) for Aggressive Mode is lower than the power required for system startup and the parameter "Shutdown System" is enabled, the server might not start normally. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
When this item is changed to/from "Overwrite oldest SEL", all log records in the SEL Repository are cleared. Disabling Platform Event Filter also disables SNMP alert. When BMC can be managed directly from NEC ESMPRO Manager (Ver.5.4 or later), this item must be set to "Enable". If it is set to "Enable", Authentication Key is required.
<Enter> key: Resets BMC. It takes about several minute to restart BMC. Note Do not shutdown the system, reboot the system, or perform any switch operation while BMC is being reset (for approximately three minutes). Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Initializes BMC configuration settings and restores the default value. After initialization, it takes several minutes to restart BMC. Note Do not shutdown the system, reboot the system, or perform any switch operation while BMC is being initialized (for approximately three minutes). Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
- Configuration Information - Battery on EXPRESSSCOPE Engine 3. You can configure the configuration information of battery controller from Settings - Battery Controller on EXPRESSSCOPE Engine 3. See the help for EXPRESSSCOPE Engine 3 for details. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Displays battery type of the battery pack. Total Working Hours Displays total working hours of the battery pack. Recharged Count Displays recharged count of the battery pack. Full Charged Count Displays full charged count of the battery pack. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
This setting is available in case of AC-LINK setting is Stay Off, or AC-Link setting is Last State and the device is DC-OFF. Available at DC-ON after DC-OFF by Shutdown at power lost feature. (Available at DC-ON by Boot after power recovery feature or DC-ON by hand.) Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
By pressing <Enter> key, final confirmation screen below is displayed. Then type "CLEAR" and press <Enter> key. If you press <ESC> key on this screen, the process is cancelled and return to battery configuration menu. Final confirmation screen of clearing battery maintenance information Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Do not use Flash FDD to back up data. Flash FDD can be used to save temporary data. 3.1.1 Compensation for recorded data NEC does not pay compensation for data recorded on Flash FDD even if the data is lost. 3.1.2 Handling Flash FDD ...
Power consumption of the server can be controlled through the command line interface of EXPRESSSCOPE Engine 3 (BMC) or by using NEC ESMPRO Manager. This feature curves the upper limit of the power consumption, which allows more servers to be installed in the environment where the power consumption is limited.
*1: "x" in LSI Software RAID Configuration Utility Verx.xx represents the version of utility. *2: mm dd, yyy represents created date. *3: "z" in BIOS Version z.zz.zzzzzzzz represents the version of LSI Software RAID BIOS. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
To quit the utility, press the <Esc> key on the TOP menu of LSI Software RAID Configuration Utility. Exit? Select Yes. Press<CTRL><ALT><DEL> To Reboot The System When the above message appears, press <Ctrl>+<Alt>+<Del> keys. The server restarts. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Enable (If the system is restarted during Rebuild or Check Consistency, ●Auto Resume specify whether the task is continued automatically or not.) ●Disk Coercion 1GB (Forcibly pack HDDs of different size) ●Factory Default Restore the default value Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 128
Display hardware information ・Device Type Device type ・Media Type Media type(HDD or SSD) ・Capacity Capacity ・Product ID Product ID ・Revision No. Revision No. ・Link Speed Transfer rate ◇Rebuild Execute Rebuild ◇Check Consistency Check Consistency of Virtual Drive Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
New Configuration or View/Add Configuration instead. For RAID10, the Virtual Drive is configured with the maximum capacity. You cannot specify the capacity. For RAID0, you can skip the step for checking the consistency. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 130
4. Move the cursor onto the physical device to be included in the disk array, and then press the <Space> key. The display for the selected physical device changes from READY to ONLINE. New Configuration – ARRAY SELECTION MENU PORT # ONLINE A00-00 ONLINE A00-01 Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 131
Virtual Drive(s) Configured RAID Size #Stripes StripeSz Status xxx.xxxGB 64 KB ONLINE Virtual Drive 0 RAID = 1 Units = MB Size = xxxxxxMB = Off = On Accept SPAN = NO Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 132
50%. (5) RA (Read Ahead): Specify whether to use read-ahead. Parameter Remarks Does not perform read ahead. Performs read ahead. * Recommended (6) Span: Specify Span. The server does not use this feature. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 133
16. For RAID1, check the consistency on the virtual drive that has been initialized. See Chapter 2 (5.3.4 Check Consistency) for details. 17. Press the <Esc> key to return to the TOP menu and exit from LSI Software RAID Configuration Utility. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
6. Select Yes to start the rebuild process. When the Completed indication in the REBUILDING screen indicates 100%, the rebuild process is completed. 7. Press the <Esc> key to return to the TOP menu and exit LSI Software RAID Configuration Utility. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
5. Move the cursor onto the physical device to be hot spared, and then press the <Enter> key. 6. Select Make HotSpare. 7. When you select Yes, the display for the physical device changes to “HOTSP”. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 136
To cancel the hot spare setting, select Objects and then Physical Drive, move the cursor onto the physical device to be canceled for hot sparing, press the <Enter> key, and then select Change Drv State. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
When the Completed indication on the CC Under Progress screen indicates 100%, the consistency check is completed. 7. Press the <Esc> key to return to the TOP menu and exit LSI Software RAID Configuration Utility. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
The available value is between 0% and 100%. The default value (recommended) is 30%. (4) Physical device information Use this feature to display physical device information. From the TOP menu, select Objects, Physical Drive, select the target physical device, and then Drive Properties. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
SETUP by pressing the < F2> key while expanding option ROM.) If you fail to press <F2> key, or the system proceeds without displaying the Tips following screen, restart the system, and press <F2> keys on POST screen. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
If you select UEFI Driver Configuration and press the <Enter> key, the following submenu appears. Select LSI Software RAID Configuration Utility and press the <Enter> key. The TOP menu of LSI Software RAID Configuration Utility appears. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Quitting LSI Software RAID Configuration Utility To quit the utility, press the <Esc> key on the TOP menu of LSI Software RAID Configuration Utility When the following screen appears, the LSI Software RAID Configuration Utility is exited. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Creating the RAID Configuration Save Configuration Storing the created configuration Select RAID Level Selecting the RAID level Selecting the Physical Drive creating the Virtual Select Drives From Drive Select Drives Selecting the Physical Drive creating the RAID Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 143
Physical Drive status Coerced Size (MB) Other Physical Drive size Device Type Physical Drive type Connected Port Port number Media Errors Media error count Predicted Fail Count Failure prediction count Available Size (MB) Available remained size Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 144
Start Operation Starting the operations to the Physical Drive Cancel of the operations being executed in the Stop Operation Physical Drive. > View Global Hot Spare Drives Device-dependent Display of the Global Hot Spare Drive Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Exit LSI Software RAID Configuration Utility Run LSI Software RAID Configuration Utility. From the TOP menu screen, select Virtual Drive Management, and then Create Configuration. For Select RAID Level on the following screen, select the RAID level (RAID0/RAID1/RAID10). Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 146
Select Select Drives, and then select the device type for Select Media Type. Note Do not select Both. This platform does not support Both of Media Type. The options for Select Media Type vary depending on the connected device. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 147
Select all of the physical devices to be created, select Apply Changes, and then select OK on the next screen. Note You may select either of the upper or lower Apply Changes which is provided at two locations. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 148
Selecting “Disable” degrades performance by approximately 50%, comparing with the “Enable” setting. 5-5. Read Ahead: Specify the Read Ahead setting. Parameter Remarks Disable Does not perform read ahead. Enable* Performs read ahead. * Recommended Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 149
When all the settings are completed, select Save Configuration. Note You may select either of the upper or lower Save Configuration which is provided at two locations. Select Yes, and then select OK on the next screen. A virtual drive is created. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 150
Select “Select Drives” under Span1, and then select the device type for Select Media Type. Note The Both option is not available. The options for Select Media Type vary depending on the connected device. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 151
Select all of the physical devices to be created, select Apply Changes, and then select OK on the next screen. Note You may select either of the upper or lower Apply Changes which is provided at two locations. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 152
Select all of the physical devices to be created, select Apply Changes, and then select OK on the next screen. Note You may select either of the upper or lower Apply Changes which is provided at two locations. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 153
8-3. Read Ahead: Specify the Read Ahead setting. Parameter Remarks Disable Does not perform read ahead. Enable* Performs read ahead. * Recommended Note For RAID 10, the virtual drive can be created only with the maximum size. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 154
When all of the settings are complete, select Save Configuration. Note You may select either of the upper or lower Save Configuration which is provided at two locations. 10) Select Yes, and then select OK on the next screen. The virtual drive is created. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 155
Chapter 2 Useful Features 5. RAID System Configuration 4-3. Additional creation Select “Free Capacity” of Select Drives From. Select Select Drive Groups. Select the Drive Group to be additionally created from Choose Drive Group, and set to “Enabled”. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 156
Drive Group setting is also changed. When all the settings are completed, select Save Configuration. Note You may select either of the upper or lower Save Configuration which is provided at two locations. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 157
When multiple virtual drives are created, for Select Virtual Drive, select the virtual drive you want to check. Press the <Esc> key to return to the previous screen, and select Select Virtual Drive Operations. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 158
Select “Virtual Drive Operation”, and then select “Fast Initialization” on the following screen. Important In the UEFI mode, Full Initialization on the LSI Software RAID Configuration Utility takes so long time, so do not select it. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 159
11. Install the OS. You don’t need to install the OS if the created virtual drive is not for booting the OS. After the OS is installed, install Universal RAID Utility. For more information about how to install, refer to the User's Guide that comes with this server. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 160
Inconsistency may be detected at the first time of the consistency check, but, there is no problem. Note For RAID0, running Check Consistency is not required. 13. Pressing the <Esc> key to return to the TOP menu and exit the utilities. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Replace a physical device, and then restart the server. Run LSI Software RAID Configuration Utility. From the TOP menu, select Drive Management, and then Select Drive Operations. The following screen appears. Confirm that the target physical device is displayed for Select Drive. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 162
The status of Operation Progress is not automatically updated. If you want to update the progress status, press the <Esc> key to return previous screen and then select Select Virtual Drive Operations again. Exit LSI Software RAID Configuration Utility. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Exit LSI Software RAID Configuration Utility Connect a physical device for hot sparing, and then turn on the server. Run LSI Software RAID Configuration Utility. On the TOP menu screen, select Drive Management. The following screen appears. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 164
Chapter 2 Useful Features 5. RAID System Configuration Select Select Drive, and then select the physical device for hot sparing. Select Drive Operation. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 165
Chapter 2 Useful Features 5. RAID System Configuration Select Assign Global Hot Spare Drive. Select Start Operation, and then select OK. Return to the TOP menu screen. Select Drive Management. Select View Global Hot Spare. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 166
5. RAID System Configuration Confirm that a hot spare drive has been created. Exit LSI Software RAID Configuration Utility. Note To cancel the HotSpare setting, select Drive Management, Select Drive Operations, and then select “Unassign Hot Spare Drive”. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
For RAID0, running Check Consistency is not required. Run LSI Software RAID Configuration Utility Run Check Consistency Exit LSI Software RAID Configuration Utility From the TOP menu of LSI Software RAID Configuration Utility, select Virtual Drive Management. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 168
Chapter 2 Useful Features 5. RAID System Configuration Select Select Virtual Drive Operations. Select the target virtual drive for Select Virtual Drive, Select "Virtual Drive Operation". Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 169
Chapter 2 Useful Features 5. RAID System Configuration Select "Check Consistency". Select Start Operation. Select Yes on the next screen. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 170
The status of Operation Progress is not automatically updated. Press the <Esc> key to return to the screen to the upper position once, the progress status is updated when the mode enters Select Virtual Drive Operations. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
(4) Physical device information Use this feature to display physical device information. From the TOP menu, select Drive Management and then View Drive Properties, and then select Select Drive to select the physical device you want to check. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Number starting from 0 Number starting from 1 Assigned based on Enclosure Physical Drive (Physical Device) Number starting from 0 number and slot number Drive Group (Disk Array) Number starting from 0 Number starting from 1 Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 173
Initialization priority) and BGI Rate (Background Initialization Priority). But Universal RAID Utility cannot set Background Initialization Priority. Initialization Priority cannot be set by Universal RAID Utility in LSI Embedded MegaRAID. To set the initialization priority, use LSI Software RAID Configuration Utility. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
After installing Starter Pack in the server, you can run EXPRESSBUILDER as a Windows application. Run NEC EXPRESSBUILDER from Windows Start Menu or run the shortcut on the desk top. When EXPRESSBUILDER starts as a Windows application, Autorun Menu shown in Chapter 2 (6.2 Menus of EXPRESSBUILDER) - (4) Autorun Menu will appear.
You can remotely operate EXPRESSBUILDER by using BIOS Console Redirection when choosing Tool menu (Redirection mode). The menu items and the tools are the same as those in normal mode. Tips Choose the normal mode when using the remote KVM feature. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 176
Return to the previous menu Choose Test and diagnostics to run System Diagnostics, which is used to analyze and diagnose the server and check the cable connection. For details, see Chapter 1 (8. System Diagnostics). Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 177
Installs or runs an application individually. e) Files for Setup Creates the file for Windows installation. f) Maintenance Updates Internal Flash Memory or copies the application files to removable media. g) Exit Closes the menu. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
RAID Configuration Data Saves or loads the configuration data on a RAID controller. File Execution Directly runs an external utility on removal media. Use this feature for utilities provided by NEC. Note Do not run the file provided by a third party.
* N8115-04 Remote KVM and Media License are required to activate these features. To actualize these features, virtual USB mass storage (Remote FD, Remote CD/DVD, Remote USB Memory, or Virtual Flash) is always connected as USB mass storage. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Chapter 2 Useful Features 8. NEC ESMPRO NEC ESMPRO NEC ESMPRO ServerAgentService (for Windows) For details of NEC ESMPRO ServerAgentService (for Windows), see "NEC ESMPRO ServerAgentService Installation Guide (Windows)" in EXPRESSBUILDER. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
8. NEC ESMPRO NEC ESMPRO Manager NEC ESMPRO Manager can remotely control and monitor the hardware and the RAID system of the server. To use these features, install the bundle software for the server such as NEC ESMPRO ServerAgentService. For details, see "NEC ESMPRO Manager Installation Guide" or online help.
Chapter 2 Useful Features 8. NEC ESMPRO NEC ESMPRO Agent Extension NEC ESMPRO Agent Extension enables you to manage the server remotely by this server's BMC connecting with NEC ESMPRO Manager. For details, see "NEC ESMPRO Agent Extension Installation Guide" in EXPRESSBUILDER.
9. NEC Product Info Collection Utility NEC Product Info Collection Utility NEC Product Info Collection Utility can collect various logs related to the server all at once. You can collect the server information (Product Info) for maintenance by using this utility.
Chapter 2 Useful Features 10. Ezclct Viewer Ezclct Viewer Ezclct Viewer can display the log files collected by NEC Product Info Collection Utility. For details, see " Ezclct Viewer User’s Guide" in EXPRESSBUILDER. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Four or more physical devices are needed to create a RAID 6 logical drive by using Universal RAID Utility. If you want to create a RAID 6 logical drive from three physical devices, use LSI Software RAID Configuration Utility or Off-line Utility. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
12. Express Report Service / Express Report Service (HTTPS) Express Report Service / Express Report Service (HTTPS) For details about Express Report Service / Express Report Service (HTTPS), see “Express Report Service / Express Report Service (HTTPS) Installation Guide (Windows)” in EXPRESSBUILDER. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Chapter 2 Useful Features 13. Express Report Service (MG) Express Report Service (MG) For details about Express Report Service (MG), see “Express Report Service (MG) Installation Guide (Windows)” in EXPRESSBUILDER. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
3. Accessing Data for Electrical Power, Temperature, and Processor Utilization Describes how to check power consumption in watts, intake temperature, and logical processor utilizations. 4. Glossary Describes glossaries of this document. 5. Revision Record Describes revision history of this document. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
The next table lists the error messages and the actions to solve the problem. If the error does not change even if the action is performed, contact your sales representative. Tips Write down the displayed messages and the beep code before contacting your sales representative. The messages are useful information for maintenance. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 190
Run SETUP, select Advanced Serial Port Option ROM expansion in PCI slot Expansion ROM not Configuration, and specify the different settings 1B failed. initialized - PCI Slot 1B for Serial Port A and Serial Port B. (Express5800/ R110i-1) Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 191
PCI Slot 1 - PCIe Link Width detected in PCI slot 1. Error (Express5800/T110i, T110i-S) PCI Slot 1A - PCIe Link Width A PCIe bus link width error was Error detected in PCI slot 1A. (Express5800/R110i-1) Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 192
C062 2nd SMBus device Error Bus. detected. An error occurred in the 3rd SM C063 3rd SMBus device Error Bus. detected. An error occurred in the 4th SM C064 4th SMBus device Error Bus. detected. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 193
BMC Configuration area corrupted. Configuration area. C123 BMC eMMC inaccessible. Failed to access to BMC eMMC. C125 BMC eMMC mode error. BMC eMMC mode error. C126 BMC eMMC partition An error occurred on BMC eMMC corrupted. partition. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 194
BIOS Configuration Data. C628 System configuration data The SETUP setting was cleared Run SETUP, and then specify the necessary cleared by System Boot by Set System Boot Options of the settings. Options command. standard IPMI command. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 195
Contact your sales representative. Resetting the system failed. Contact your sales representative. An error was detected during allocating the Remove all the PCI boards from the PCI slots, PCI resources. and then restart the server. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 196
BIOS recovery is in progress. Wait until the BIOS recovery process completes. BIOS Recovery Running BIOS Updater BIOS update is in progress. Wait until the BIOS update process completes. Running Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 197
Correctable Error (x: 1-4) DIMM #x An uncorrectable memory error Contact your sales representative. Uncorrectable occurred in DIMM #x. Error (x: 1-4) Memory A failed DIMM was detected and Contact your sales representative. Reconfigured degraded. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 198
Baseboard Temperature2 Lower Non-Critical Baseboard Temperature2 Upper Non-Critical Baseboard Temperature2 Lower Critical Baseboard Temperature2 Upper Critical Ambient Temperature Lower Non-Critical Ambient Temperature Upper Non-Critical Ambient Temperature Lower Critical Ambient Temperature Upper Critical DIMM Area Temperature Lower Non-Critical Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 199
An internal CPU error (IERR) Processor Internal Error occurred. Abnormality in a sensor was Sensor Failure Detected. detected. SMI timeout A timeout occurred while servicing system management interrupts. IPMI Watchdog timer timeout A watchdog timer timeout occurred. (Power off) Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 200
Storage Integrity Error Drive 0 Fault Operation was performed during hard disk drive failure Drive 1 Fault Drive 2 Fault Drive 3 Fault Drive 4 Fault Drive 5 Fault Drive 6 Fault Drive 7 Fault Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 201
System FAN4 Lower Non-Critical System FAN5 Lower Non-Critical System FAN6 Lower Non-Critical System FAN7 Lower Non-Critical System FAN8 Lower Non-Critical System FAN9 Lower Non-Critical System FAN10 Lower Non-Critical System FAN11 Lower Non-Critical System FAN12 Lower Non-Critical Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Broadcom NetXtreme Gigabit Ethernet #xx: The network link is down. Warning b57nd60a Check to make sure the network cable is properly connected. When installing an OS, starting system, This event does not affect system operation. or applying Starter Pack Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 203
The server {XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX} did not Microsoft-Windows- Error register with DCOM within the required timeout. DistributedCOM 10010 Refer to the following website. When running an OS for the first time or rebooting it http://support.microsoft.com/kb/956479/ Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 204
Windows. License acquisition failure details. Microsoft-Windows- Error Security-SPP hr=0x80072EE7 8200 When starting system and installing This event does not affect system operation if it is not recorded Starter Pack repeatedly after activating the Windows. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 205
WAP messages received by SMS Router. Result: (0xC002000B). Pushrouter This event does not affect system operation if it is recorded only on the When running an OS for the first time first startup and not recorded repeatedly. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 206
Utility, there is no problem in system operation. When creating logical drive by Universal The character string of the event will be correctly displayed by applying RAID Utility the Microsoft's update program on the following site: http://support.microsoft.com/kb/2925479 Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 207
Failed to obtain end-user license. Error Security-SPP hr=0x80072EE7 1014 If this event is logged only when installing an OS and does not occur When installing an OS repeatedly, there is no problem in system operation. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 208
Error: 'Class not registered' (0.0469065 sec.) AppReadiness If this event is logged only at the first sign-in after OS installation and When installing an OS does not occur repeatedly, there is no problem in system operation. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 209
The server {xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx} did not register Microsoft-Windows- Error DistributedCOM with DCOM within the required timeout. 10010 Go to the following website for details. When installing an OS http://support.microsoft.com/kb/956479/ Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 210
Microsoft-Windows- Warning The Network List Manager reports no connectivity to the internet. DeviceSetupManager If it is not registered after the Internet connection is established, there is When running the system no problem with system operation. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 211
Error VID (Virtual Infrastructure Driver) is not running. Hyper-V-VMMS 15350 This event is logged at shutdown of Windows Server 2012 with Hyper-V When running the system enabled. However, this event does not affect system operation. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 212
You can increase the timeouts associated with the IPMI device driver. 1004 The above event log may be recorded. Usually, however, IPMI When running the system command retry processing is performed, so there is no operation problem. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 213
= 0x80070013, This media is read-only volume. When you import a transportable shadow-copy to another server that has a Go to the following Microsoft website for details: read-only volume while operating http://support.microsoft.com/kb/2003016/en-us Windows Server 2008 R2: Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 214
When installing an OS, running an OS for If this event is logged when installing an OS, running an OS for the first the first time, or applying Starter Pack time, or while applying Starter Pack, it does not affect system operation. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
WScript.Echo " Power Consumption = " & outparams.ResponseData(3)*256 + _ outparams.ResponseData(2) & " watts" End If ' End Script Command example C:¥VBS> cscript //nologo Power.vbs Result Completion Code = 0x0 Power Consumption = 76 watts The power consumption is 76 watts. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
GetSensorType(Reserve_LS, Reserve_MS, Record_LS, Record_MS, sensorType) If sensorType = 1 Then ' Temperature WScript.Echo "===========================================" call GetIDString(Reserve_LS, Reserve_MS, Record_LS, Record_MS) WScript.Echo " Sensor Type = Temperature" sensorNum = outparams.ResponseData(10) call GetSensor(Reserve_LS, Reserve_MS, Record_LS, Record_MS,sensorNum) End If End If Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 217
Sub get2complement(raw, rv, bit) Select Case bit case 4: If raw And &h8 Then rv = 0 - ((&h10 - raw) and &h0f) Else rv = raw End If case 8: If raw And &h80 Then Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Page 218
Amb, Ambient, or Front Panel. In the case of the sample above, the data is read from a sensor that contains Fnt Pnl Temp in its ID, with a resulting intake air temperature of 27C. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
Proc4 : PercentProcessorTime=76 Proc5 : PercentProcessorTime=0 Proc6 : PercentProcessorTime=0 Proc7 : PercentProcessorTime=0 Proc_Total : PercentProcessorTime=9 Proc 0 to Proc 7 show the utilization rate of each processor while Proc_Total shows the total processor utilization rate. Express5800/R110i-1, T110i-S, T110i Maintenance Guide...
NEC ESMPRO Manager Software for managing a number of servers on network. NEC ESMPRO Software for monitoring the server. This works with NEC ESMPRO Manager. You can ServerAgentService choose Service Mode or Non-Service Mode when installing this software. Service Mode resides as the OS service and Non-Service Mode does not use the OS service to reduce memory, CPU power, and other OS resources.
Chapter 3 Appendix 5. Revision Record Revision Record Revision (Document Number) Date Issued Description 10.116.01-104.01 April 2017 Newly created 10.116.01-104.02 May 2018 Support new RAID controller Express5800/R110i-1, T110i-S, T110i Maintenance Guide...