Liquid service port
<High pressure>
Correct
Inclined
Cracked
<Flare nut>
NOTE
• Excessive torque may cause gas leakage. When
extending the pipe with welding or brazing,
ensure that nitrogen is used during the welding or
brazing process. The joint must be accessible and
serviceable.
CAUTION
• Tighten the flare nut at the specified torque. If the
flare nut is over-tightened, it may break to cause
leakage of refrigerant gas.
Gas service port
<Low pressure>
Uneven
Damaged
thickness
surface

Step 2.10 Fixing the installation plate

You can install the indoor unit on a wall, window
frame, or gypsum board.
WARNING
• Make sure that the wall, window frame, or
gypsum board can withstand the weight of the
indoor unit. If you install the indoor unit in a place
where it is not strong enough to withstand the
unit's weight, the unit could fall and cause injury.
When fixing the indoor unit on a wall
Fix the installation plate to the wall giving attention
to the weight of the indoor unit.
Plastic anchor
Wall
20 mm
Model
**07*******
**09*******
**12*******
NOTE
• If you mount the plate to a concrete wall using
plastic anchors, make sure that gaps between the
wall and the plate, created by projected anchor, is
less than 20 mm.
When fixing the indoor unit on a window frame
1 Determine the positions of the wooden uprights
to be attached to the window frame.
2 Attach the wooden uprights to the window frame
giving attention to the weight of the indoor unit.
3 Attach the installation plate to the wooden
upright using tapping screws.
(Unit : mm)
A
B
C
D
36
190
81
36
Pipe bundle hole: Ø 65 mm