Page 1
2013 Plasma TV Technical Guide Plasma FHD TV – S/ST Series (16th Generation) Applies to models: TC-P42S60 TC-P50S60 TC-P55S60 TC-P60S60 TC-P65S60 TC-P50ST60 TC-P55ST60 TC-P60ST60 TC-P65ST60 National Training Department Panasonic Consumer Marketing Company of North America TTG130423CP Slide 1...
Table of Contents Table of Contents Subject Slide No. Index Model Line Up and New Features 5 - 9 Board Layout and connectors Location 10 - 18 Standby Operation 19 - 27 Power On Operation 28 - 36 Voltage Distribution 37 - 56 SOS Detect Circuit Explanation 57 - 59...
Index Model Line Up and New Features Board Layout and connectors Location Standby Operation Power On Operation Voltage Distribution SOS Detect Circuit Explanation Shutdown) TV Data Copy to USB Drive Troubleshooting Flowchart Video/Lines Troubleshooting Slide 4...
Page 6
2013 PDP TV Line-up Type Classification Model No. TC-P60ZT60 Flagship TC-P65ZT60 TC-P65VT60 Premium TC-P60VT60 TC-P55VT60 TC-P65ST60 TC-P60ST60 Core TC-P55ST60 TC-P50ST60 TC-P65S60 TC-P60S60 Leader TC-P55S60 TC-P50S60 TC-P42S60 TC-P50X60 Entry TC-P42X60 XT, U, UT, and GT series are not available for 2013. Slide 6...
Page 7
Models Comparison Built-in Skype camera on VT Series. No Power Supply SOS (SOS4) for FHD models. F15V is now the source of the S15V used for audio amplification. The AC inlet is now located on the power supply board. SD card can not be used for Data Copy. Slide 7 Slide 7...
Page 8
New Features Voice Guidance SMART VIERA Voice Guidance uses text to speech functions to verbalize text contents on TV. It is great for verbally reading out program information, SNS messages as well as web page contents. My Home Screen Get instant and easy access to your favorite Smart TV contents. TV Begins with Your Own Personalized Screen.
Page 9
Bluetooth device. This device works will all 2013 models except X6 series 3D Eyewear TY-ER3D4SU TY-ER3D4MU Rechargeable Panasonic 3D Eyewear supporting Bluetooth wireless technology. Communication Camera This camera can be used as a the video communication tool. TY-CC20W...
Page 20
Standby Operation TC-P42/50S60 Condition when the TV is first plugged in IC5000 IC8000 3.3V STB5V Peaks sLD8 ANALOG Signal Circuit ASIC Processor REMOTE F_STBY_ON REC. KEYSCAN RMIN Command POWER SWITCH Slide 20...
Page 21
Standby Operation TC-P42/50S60 When the TV is plugged in: AC is applied to the standby circuit in the PSS board to produce STB5V. The STB5V is provided to the A board via pin 22 of connector P6. The STB5V from pin 22 of connector A6A is applied to the Analog ASIC (IC5000) The Analog ASIC IC5000 converts the STB5V to STB3.3V.
Page 22
Standby Operation TC-P55/60/65S60 TC-P**ST60 (All ST60) Condition when the TV is first plugged in Besides the standby voltages, another set of voltages is output for approximately 8 seconds right after AC is first applied to the TV. After 8 seconds, these voltages are no longer present and the power supply goes back to standby mode.
Page 23
Standby Operation TC-P55/60/65S60 TC-P**ST60 (All ST60) First 8 seconds after the TV is first plugged in (Block Diagram) IC5000 IC8000 DC/DC Circuit Circuit T200 3.3V STB5V 3.3V AC DET PARAGON ANALOG 3.3V Signal ASIC Processor RL100 XRST REMOTE STB5V_ON STB_RST POWER REC.
Page 24
Standby Circuit Explanation TC-P55/60/65S60 First 8 seconds after the TV is first plugged in (Block Diagram) TC-P**ST60 (All ST60) AC from connector P9 flows through the resistor across the relay switch energizing the standby circuit. Note: At this point the relay has not been triggered. The standby circuit outputs the STB5V to pin 5 of connector P6.
Page 25
Standby Operation TC-P55/60/65S60 TC-P50ST60 TC-P**ST60 (All ST60) Condition 8 seconds after the TV is first plugged in. STB5V 3.3V STB3.3V After 8 seconds, only STB5V and STB3.3V remain present 8~11 seconds after the TV is first plugged in and the relay click is heard for a second time, the TV goes back to normal standby mode and only the STB5V and STB3.3V are present.
Page 26
Protection Circuit Block Diagram (At Plug in) SUB5V/SUB3.3V Abnormalities of any of the voltages generated at this time can cause any of the following conditions: Possible Conditions • No Power/Dead • 3 Fast Blinks • 6 Blinks • 10 Blinks SUB5V IC8000 SUB5V/SUB3.3V Over...
Page 28
Power-On Operation (Power On Commands) TC-P42S60 TC-P50S60 Condition when the TV is first plugged in 3.3V IC5000 3.3V IC8000 STB5V Peaks sLD8 ANALOG Signal ASIC F15V Processor REMOTE REC. F_STBY_ON 3.3V PANEL_MAIN_ON KEYSCAN RMIN Command POWER SWITCH Slide 28...
Page 29
Power-On Operation (Power On Commands) TC-P42S60 - TC-P50S60 Pressing the power switch to turn on the TV TC-P42S60 (FHD Models with the P and SS circuits combined) TC-P50S60 The TV can be turned on in 2 different ways: Pressing the power switch on the TV...
Page 30
Power On Commands (All ST60 Models + 55”, 60”, and 65” S60 Models) TC-P55/60/65S60 Pressing the power switch to turn on the TV TC-P**ST60 (All ST60) 2.8V PANEL_MAIN_ON 1.5V F_STBY_ON IC8000 IC5000 3.3V STB5V PARAGON ANALOG Signal Circuit ASIC Processor PWR LED RMIN REMOTE...
Page 31
Power On Commands (All ST60 Models + 55”, 60”, and 65” S60 Models) TC-P55/60/65S60 TC-P**ST60 (All ST60) Pressing the power switch to turn on the TV The TV can be turned on in 2 different ways: Pressing the power switch on the TV Pressing the power switch on the remote control Pressing the power switch on the TV Note: On these models, the power switch is located on the Control Assembly.
Page 32
Power-On Operation (F_STB_On Command + F15V/SUB Voltages) TC-P55/60/65S60 F15V and SUB Voltages TC-P**ST60 (All ST60) IC5000 IC8000 DC/DC Circuit T200 3.3V STB5V 3.3V AC DET PARAGON ANALOG 3.3V Signal ASIC Processor RL100 XRST REMOTE STB5V_ON STB_RST POWER REC. 3.3V MICOM IC502 1.5V F_STB_ON...
Page 33
Power-On Operation (F_STB_On Command + F15V/SUB Voltages) TC-P55/60/65S60 TC-P**ST60 (All ST60) F15V and SUB Voltages After receiving the power on command from the power switch on the TV or the remote control: IC8000 outputs the F_STB_ON command (DC1.5V ~ 3.2V). F_STB_ON is applied to pin 6 of connector P6 on the P board to be connected to the power micom (IC502).
Page 35
Power-On Operation (Panel Drive Voltages Vsus/Vda/P15) TC-P55/60/65S60 TC-P**ST60 (All ST60) Panel Drive Voltages Vsus – Vda – P15V After all the SUB Voltages are generated and all circuits are confirmed to be normal by IC8000, then the Panel Main On (DC1.5V~3V) command is output. Panel Main is applied to pin 1 of connector P6 on the P board to be connected to the power micom IC502.
Page 43
Voltage Distribution(3) F15V and Sub-Voltages Circuit Explanation The F15V from the power supply is connected to pins 5/6 of connector A6 of the A board. After passing the pin 5/6 of A6 connector, F15V is applied to 6 components. Application Specific IC(IC5000), the voltage regulators IC8704,IC8705, IC8100, IC8101 and IC9803. These ICs above except IC5000, are activated by DCDCEN, DCDCEN2, P_OOPCTRL11 and P_TCON9.
Page 44
Behavior Comparison Between 2012 and 2013 Models When the TV Fail with Shorted Vsus, Vda, or P15V The table below indicates the condition of the TV if a short circuit is developed on any of the panel drive voltages. Year 2012 2013 Series...
Page 45
Behavior Comparison Between 2013 Models When Connectors are Removed. Removal connector Result Result Result (TC-P42/50S60) (TC-P55/60/65S60) (TC-P50/55ST60) C25(P35) The TV stays on The TV stays on The TV stays on with black screen. with black screen. with black screen. Any combination of 6 blinks (after 11 sec.) 6 blinks (after 11 sec.) 8 blinks...
Page 46
Voltage Distribution (Panel Drive Voltages Vsus) Analysis of a shorted Vsus condition Depending on the model, a short circuit of the Vsus can cause a 3 fast blinks or a normal 7 blinks condition. Slide 46...
Page 47
Voltage Distribution (Panel Drive Voltages Vsus) Analysis of a shorted Vsus condition Depending on the model, a short circuit of the Vsus can cause a 3 fast blinks or a normal 7 blinks condition. Vsus is generated by the Power supply and is used by the SC and the SS boards. A shorted Vsus is usually caused by the SC board or the SS board and very rarely the power supply is damaged when this occurs.
Page 48
(Panel Drive Voltages Vda) Voltage Distribution Analysis of a shorted Vda condition Depending on the model, a short circuit of the Vsus can cause a 3 fast blinks or a normal 8 blinks condition. Slide 48...
Page 49
(Panel Drive Voltages Vda) Voltage Distribution Analysis of a shorted Vda condition Depending on the model, a short circuit of the Vsus can cause a 3 fast blinks or a normal 8 blinks shutdown condition. A shorted Vda caused by the panel will not trigger a 3 nor an 8 blinks shutdown condition because of the 1 ohm fusible resistors used on the C boards.
Page 50
Voltage Distribution (Panel Drive Voltages Vda) Analysis of a shorted Vda condition A shorted Vda caused by the panel will not trigger a 3 nor an 8 blinks shutdown condition because of the 1 ohm fusible resistors used on the C boards. The resistor in line with the defective IC on the panel causing the short circuit opens allowing the TV to stay on.
Page 51
Voltage Distribution (Panel Drive Voltages Vda) Analysis of a shorted Vda condition The following is an example of a 50” Plasma TV, which normally has a total of 15 connectors between the C boards and the panel. If one of the ICs on the flex cable (FPC) is shorted, the respective resistor on the C board opens and a 3”...
Page 52
(Panel Drive Voltages P15/P5V) Voltage Distribution Analysis of a shorted P15 condition Slide 52...
Page 53
(Panel Drive Voltages P15V) Voltage Distribution Analysis of a shorted P15V condition Depending on the model, a short circuit of the P15V can cause a 3 fast blinks, a 2 blinks or an 8 blinks shutdown condition. P15V is generated by the Power supply and is used by the A board, the SC board, and the SS board.
Page 54
Behavior Comparison Between 2012 and 2013 Models When the TV Fail with Shorted Vsus, Vda, or P15V Year 2012 2013 Series UT50 ST50 GT50 42/50S60 55/60/65S60 ST60 Vsus Fast 7 Blinks 7 Blinks Fast 7 Blinks 7 Blinks 3 Blinks 3 blinks No SOS.
Page 55
Behavior Comparison Between 2013 Models When Connectors are Removed. Removal connector Result Result Result (TC-P42/50S60) (TC-P55/60/65S60) (TC-P50/55ST60) C25(P35) The TV stays on The TV stays on The TV stays on with black screen. with black screen. with black screen. Any combination of 6 blinks (after 11 sec.) 6 blinks (after 11 sec.) 8 blinks...
SOS Detect Circuit Explanation (Shutdown) Slide 56...
Page 57
SOS Detect Circuit Explanation Important Information • When the 2013 Plasma TV fail with a shutdown condition making the power LED blink, it turns • When the 2013 Plasma TV fail with a shutdown condition making the power LED blink, it turns on automatically when it’s disconnected and plugged in again regardless of the time it has on automatically when it’s disconnected and plugged in again regardless of the time it has been unplugged.
Page 58
SOS Detect Circuit Explanation (2) SOS Precautions When an abnormality occurs in the unit, the “SOS Detect” circuit is triggered and the TV shuts down. The power LED on the front panel will flash a pattern indicating the circuit that has failed. Cautions: If the power LED continues to blink even after the TV is unplugged, press and hold the power switch on the TV for a few seconds until the LED turns off.
Page 59
SOS Detect Circuit Explanation (3) SOS Detect Circuit (1 of 3) Protection circuits are incorporated in the unit to prevent the failure of a single circuit or component from creating catastrophic damage. A shutdown condition occurs when there is an over voltage, a short or a drop in any of the voltage lines.
Page 60
SOS Detect Circuit Explanation 2 Blinks Error Code These conditions can cause the TV to shutdown and the power LED to blink 2 time Missing P15V Wrong diagnostic by the A board SOS 2 AM16 P15V P15V T200 PARAGON P15V STBY uCOM MONITORING CIRCUIT...
Page 61
SOS Detect Circuit Explanation SOS Detect Circuit Explanation (7) 6 Blinks Error Code Circuit Explanation These conditions can cause the TV to shutdown and the power LED to blink 6 times SC board defect A board defect Disconnection of C board and A board Wrong diagnostic by A board 36V <...
Page 62
SOS Detect Circuit Explanation 6 Blinks Error Code Circuit Explanation These conditions can cause the TV to shutdown and the power LED to blink 6 times SC board defect A board defect Disconnection of C board and A board Wrong diagnostic by A board P3.3V IC9300 IC5000...
Page 63
SOS Detect Circuit Explanation (9) 7 Blinks Error Code These conditions can cause the TV to shutdown and the power LED to blink 7 times VAD or VSCN circuit defect Disconnection of SC and SU/SD board F5V / F15V abnormal voltage VAD / VSCN abnormal voltage Other error IC5000...
Page 64
SOS Detect Circuit Explanation (10) 7 Blinks Error Code These conditions can cause the TV to shutdown and the power LED to blink 7 times VAD or VSCN circuit defect Disconnection of SC and SU/SD board F5V / F15V abnormal voltage VAD / VSCN abnormal voltage SC20 Other Error...
Page 65
SOS Detect Circuit Explanation (11) 8 Blinks Error Code These conditions can cause the TV to shutdown and the power LED to blink 8 times 1.Failure of SS board 2.Disconnection of SS (SS2) board and Panel 3.Wrong diagnostic by the A board PANEL SS52 Disconnect detection...
Page 66
SOS Detect Circuit Explanation (12) 9 Blinks Error Code These conditions can cause the TV to shutdown and the power LED to blink 9 times 1.Failure of the Discharge Control Circuit – DCC (IC9300) 2.Wrong diagnostic by the A board Video data to C board LVDS IC9300...
Page 67
SOS Detect Circuit Explanation These conditions can cause the TV to shutdown and the power LED to blink 10 times A board defect (SUB3.3V or SUB5V is overvoltage) Wrong diagnostic by the A board == Easy Measurement Point == ・SUB3.3V is applied to 3 pin of A1 connector via SUB_AI_3.3V. ・SUB5V is applied to 1 pin of IC8602/8603 (USB switch IC).
Page 68
SOS Detect Circuit Explanation (14) 12 Blinks Error Code These conditions can cause the TV to shutdown and the power LED to blink 12 times Speaker A board (mainly sound processor) 3. Wrong diagnostic by the A board PROT_N AF22 Speaker L IC4900 (YDA174)
Page 70
TV Data Copy to USB Drive Quick Procedure to Copy the TV’s Data to a USB Drive. The following data can be copied from the TV to an USB Drive: • User settings data (Including hotel mode setting data). • Channel scan data.
Page 71
Quick Procedure to Copy the USB Drive Data to a TV Procedure to copy the data from the USB Drive to a TV: Connect the USB Drive with the copied TV data. Enter the appropriated password when prompted: • Enter 2771 for A board replacement •...
Page 72
Detailed Procedure to Copy the TV’s Data to a USB Drive (1 of 2) Note: Notepad and MS Create a startup file on a USB Drive for “A” board replacement or hotel data: Word can also be used Connect a blank USB Drive to your PC. to create a “.txt”...
Page 73
Detailed Procedure to Copy the TV’s Data into a USB Drive (2 of 2) 1 - Turn on the TV 2 – Connect the USB Drive to the USB connector. The .pwd file on the card will be recognized by the TV when the USB Drive is connected to the TV. 3 - Enter the password when the “Input Password”...
Page 74
Detailed Procedure to Copy Data From USB Drive to The TV To copy the data from the USB Drive to the TV: 1. Turn on the TV. 2. Insert the USB Drive with the copied data into the USB connector. 3.Using the Remote Control, enter the appropriated password when the “Input Password”...
Page 76
Power LED Error Code Definition (TC-P**S60) POWER LED CIRCUIT CONDITIONS TRIGGERING LIST OF BOARDS POSSIBLY CASUSING THE FAILURE ERROR MONITORED THE SHUTDOWN #1 Suspect #3 Occasionally #4 Not CODE Often Panel Information SOS Read error 1 BLINK Communication problem Wake up error of IC9300. 2 BLINKS P15V from the P board Missing P15V...
Page 77
Power LED Error Code Definition (TC-P**ST60) POWER LED CIRCUIT CONDITIONS TRIGGERING LIST OF BOARDS POSSIBLY CASUSING THE FAILURE ERROR CODE MONITORED THE SHUTDOWN #1 Suspect #3 Occasionally #4 Not Often 1 BLINK Panel Information SOS Read error Communication problem Wake up error of IC9300 2 BLINKS P15V from the P board Missing P15V...
Page 78
Troubleshooting 1, 9, 13 Blinks Failure (TC-P**S60, P**ST60) Applies to Models TC-P42S60 ----- TC-P50S60 TC-P50ST60 TC-P55S60 TC-P55ST60 TC-P60S60 TC-P60ST60 TC-P65S60 TC-P65ST60 Blink List of boards likely to cause this symptom Code No.1 No.2 No.3 No.4 A Board 9 Blinks A Board...
Page 79
Troubleshooting 2 Blinks Failure (TC-P42S60 – TC-P50S60) Blink List of boards likely to cause this symptom. Applies to Models For all others S60 or ST60 Code models go to the next page No.1 No.2 No.3 No.4 TC-P42S60 2 Blinks TC-P50S60...
Page 80
Troubleshooting 2 Blinks Failure (TC-P55/60/65S60, P**ST60) Blink List of boards likely to cause this symptom. Code No Specific Order Applies to Models For all others S60 models go to the 2 Blinks ---- TCP-50ST60 previous page TC-P55S60 TC-P55ST60 Start Here Place the positive lead of a voltmeter at pin 12 of connector P6 while the black lead is TC-P60S60 TC-P60ST60...
Page 81
No specific order TC-P42S60 models go to page 83 3 Blinks SN (42”) Panel TC-P50S60 Start Here SC/SS (50”) Unplug the TV. Remove any residual charge from the Vsus and Vda lines. Use a 5W 500ohms resistor. Measure the resistance between: •...
Page 82
Plug-in the TV. Note: If the power LED does not turn on automatically after the TV is plugged in as expected, then press the power switch. TC-P42S60 TC-P50S60 8 Times 3 times Is the power LED blinking 3 or 8 times?
Page 83
Troubleshooting 3 Fast Blinks Failure (TC-P55/60/65S60) ( 1 of 2) Applies to Models Blink List of boards likely to cause this symptom. For all others S60 TC-P55S60 Code models go to page 81 No specific order TC-P60S60 3 Blinks SS SC/SS Panel TC-P65S60 Start Here...
Page 84
( 2 of 2) From previous From previous slide (A) slide (B) Shorted Unplug connector P6 on the P board. Shorted Vsus Measure the resistance between pin 12 of connector P6 and ground (Chassis) Unplug connectors P2 and P11, on the P board.
Page 85
Code the next page No.1 No.2 No.3 No.4 TC-P42S60 6 Blinks SN (42”) TC-P50S60 SC(50”55”/60”/65”) TC-P55S60 TC-P60S60 TC-P65S60 TC-P42S60 Start Here Verify that all the cables on the SC/SN board are SN20 properly seated. Also check the ribbon cables and connectors on the A and C boards.
Page 86
Troubleshooting 6 Blinks Failure (TC-P**ST60) Applies to Models For S60 models go to Blink List of boards likely to cause this symptom. the previous page TC-P50ST60 Code No.1 No.2 No.3 No.4 TC-P55ST60 6 Blinks TC-P60ST60 TC-P65ST60 Make sure these TC-P50ST60 connectors are properly seated Start Here...
Page 87
List of boards likely to cause this symptom. not loose screws on the Code TC-P42S60 ----- No.1 No.2 No.3 No.4 SN/SC, SU, and SD boards. TC-P50S60 TC-P50ST60 7 Blinks SU/SD SC (SN) A/Panel TC-P55S60 TC-P55ST60 SN (42” 0nly) TC-P60S60 TC-P60ST60...
Page 88
From the previous page (2 of 4) Troubleshooting 7 Blinks Failure (VFO/VF5V Resistance Check) Using any of the VFG screws (Floating ground screws) on the SU or SD board as ground, measure the resistance of both test points: VF5V (SRV – VF5V) and VFO (SRV – VFO) on the SU board. Is there a (See the picture below.) short...
Page 89
From the previous page A – From the previous slide (3 of 4) Reconnect SU41 on the Unplug SU41 on the SU board and SU board and disconnect perform the same resistance test. SD42 on the SD board. Perform the same resistance test.
Page 90
From the previous page (4 of 4) B – From the previous slide Unplug SD42 from the SD board and perform the same resistance test. Replace the Is there a SC and SU short boards circuit? See the picture “A” on the previous slide and: •...
Page 91
List of boards likely to cause this symptom. For all others S60 or ST60 Code TC-P42S60 models go to the next page No.1 No.2 No.3 No.4 TC-P50S60 8 Blinks Note: Check for loose screws on the PSS/SS board. SS53,SS55 Start Here TC-P42S60 Check all the cables between the SS board (SS53 ,SS55) and the panel.
Page 92
Troubleshooting 8 Blinks Failure (TC-P55/60/65S60, P**ST60) Applies to Models For all others S60 Blink List of boards likely to cause this symptom. models go to the Code ----- TCP-50ST60 No.1 No.2 No.3 No.4 previous page TC-P55S60 TC-P55ST60 8 Blinks TC-P60S60 TC-P60ST60 Start Here SS52-57...
Page 93
Blink List of boards likely to cause this symptom Applies to Models Code Start Here No.1 No.2 No.3 No.4 TC-P42S60 ----- 10 Blinks TC-P50S60 TC-P50ST60 TC-P**ST60 TC-P**S60 TC-P55S60 TC-P55ST60 Models Models TC-P60S60 TC-P60ST60 TC-P65S60 TC-P65ST60 Unplug the TV. Measure the resistance...
Page 94
Applies to Models Blink List of boards likely to cause this symptom. speakers and subwoofer Code TC-P42S60 ----- No.1 No.2 No.3 No.4 wires are not pinched. TC-P50S60 TC-P50ST60 12 Blinks Speaker/ Subwoofer TC-P55S60 TC-P55ST60 TC-P60S60 TC-P60ST60 TC-P55ST60 TC-P65S60 TC-P65ST60 Speakers...
Page 95
For all others S60 or ST60 Power models go to the next page No.1 No.2 TC-P42S60 TC-P50S60 Dead Note: Verify this symptom by using both the TV’s power switch and the remote control. Start Here Make sure AC is present across connector P9 on the PSS board.
Page 96
Troubleshooting No Power/Dead Unit (Power LED is Off) Note: Verify this symptom by using both the Applies to Models For all others S60 models TV’s power switch and the remote control. go to the previous page ----- TCP-50ST60 Start Here TC-P55S60 TC-P55ST60 List of boards likely to cause this symptom...
Page 97
TC-P50ST60 2.8V PANEL_MAIN_ON 1.5V F_STBY_ON IC8000 IC5000 3.3V STB5V PARAGON ANALOG Signal Circuit ASIC Processor PWR LED RMIN REMOTE KEYSCAN REC. KEYSCAN PWR SW Control Assy POWER SWITCH Command Slide 97...
Page 98
Behavior Comparison Between 2013 Models When Connectors are Removed. Removal connector Result Result Result (TC-P42/50S60) (TC-P55/60/65S60) (TC-P50/55ST60) C25(P35) The TV stays on The TV stays on The TV stays on with black screen. with black screen. with black screen. Any combination of 6 blinks (after 11 sec.) 6 blinks (after 11 sec.) 8 blinks...
Page 99
Behavior Comparison Between 2012 and 2013 Models When the TV Fail with Shorted Vsus, Vda, or P15V Year 2012 2013 Series UT50 ST50 GT50 42/50S60 55/60/65S60 ST60 Vsus Fast 7 Blinks 7 Blinks Fast 7 Blinks 7 Blinks 3 Blinks 3 blinks No SOS.
Page 101
Troubleshooting Picture Distortions Symptom Actual Symptom Defective Board Irregular color All vertical line Abnormal electric discharge Over 50inch : SC / SS 42inch : SN / SS Slide 101 Slide...
Page 102
Troubleshooting Picture Distortions Symptom Actual Symptom Defective Board Over 50inch : SU / SD Trouble at upper or lower half 42inch : SN Over 50inch : SU / SD Horizontal line 42inch : SN or (upper or lower side) panel Trouble at left or center or right part Over 50inch : C1 –...
Page 103
Troubleshooting Horizontal Line Problem PDP panel SS,SS2 SS,SS2 SCAN DRIVE Scan Drive: Pulse timing is shifted each horizontal electrode. 1 line abnormal Sustain Drive: All the lines are same waveform. All the lines are connected mutually. A horizontal line can be caused by: A defective scan SS board doesn't cause When this cable (FFC) is damaged, drive IC , open connection to the panel or damaged...