Measurement made easy Introduction For more information — AWT210 This Communication Supplement provides Further publications for the AWT210 transmitter are 2-Wire transmitter procedures specifically related to the AWT210 available for free download from: HART® 2-wire transmitter. Refer to the AWT210 www.abb.com/measurement...
AW T 2 1 0 H A R T 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ H A R T- E N R E V. B Health & Safety Document symbols Potential safety hazards AWT210 transmitter – electrical Symbols that appear in this document are explained below: DANGER – SERIOUS DAMAGE TO HEALTH WARNING – BODILY INJURY...
Direct current supply only. manufacturer for disposal at no charge to the user. ABB is committed to ensuring that the risk of any This symbol, when noted on a product enclosure or environmental damage or pollution caused by any of barrier, indicates that a risk of electrical shock and/or its products is minimized as far as possible.
COM/AWT210/ AWT210 transmitter HART HART-FDS-EN Field Device Specification Four variants of AWT210 are available for use with pH, ORP, pIon, and conductivity sensors. HART manufacturing ID and device type The device has four dynamic variables. The device does not All HART products contain unique identifiers that specify the have any device variables.
Process Variable (detailed in commissioning instructions) and 5 location installation requirements refer to the to 8 for temperature sensor (up to 3 wire RTD + shield). AWT210 Operating Instructions (OI/AWT210-EN). Operating ranges correspond to the capabilities of each sensor • The signal/power terminals accept wire sizes type.
Do not connect secondary communication device directly across the power supply. Load resistance must include any meters external to the AWT210 transmitter, the wiring and the system input. IMPORTANT (NOTE) The equation for minimum supply voltage is based on a maximum output current of 20 mA. In some cases such as fail high or process variable over range –...
Each transmitter on the bus is wired from the primary communication device to the positive (+) and negative (–) IMPORTANT (NOTE) POWER (SIGNAL) terminals of the AWT210. Connect all Only one secondary device can communicate on the transmitters on the bus in parallel.
Read Board Object Write Object Device-specific command details such as data bytes and Read Memory response codes are described in the AWT210 HART field device Write Memory specification (COM/AWT210/HART-FDS-EN) Reset Software Write Protection Read Revision Supported HART commands...
AW T 2 1 0 H A R T 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ H A R T- E N R E V. B Device-specific HART commands: Device-specific HART commands: Four Electrode Conductivity (EC)
Page 12
We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.