Page 1
WH-ADC0309H3E5B WH-UD07HE5-1 WH-UD09HE5-1 Subject: Additional Information of Operation and Control Please file and use this supplement manual together with the service manual for Model No. WH-ADC0309H3E5 WH-ADC0309H3E5UK WH-ADC0309H3E5B Order No PAPAMY1607068CE, PAPAMY1607069CE and PAPAMY1607070CE WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public.
1. Operation and Control Auto Mode Operation 1.1.1 Auto Cooling Mode Operation Limit Compressor 19°C 16°C Compressor Outdoor Ambient Temperature Auto Mode Cooling Only operation will start once the outdoor ambient temperature reaches 19°C and compressor will continue to run until the outdoor ambient temperature drops to 16°C. ...