Description of Functions
1. Suitable for charging 12V/24V/36V/48V lead-acid batteries, including GEL, Sealed, Flooded battery
2. Mainly suitable for off-grid solar power generation systems, such as: home solar power generation system, solar RV power generation,
boat, unattended base stations, outposts and so on.
3. MPPT charging technology, three-stage charging mode, constant current charge-constant voltage charge-floating charge,
effectively improve the battery charging efficiency. It is more portable than ordinary PWM charging.
4. Suitable for high voltage input, PV voltage up to 150 V (At the lowest temperature -25℃).
5. input two Channel solar panels at the same time.
6. This product adopts intelligent single-chip microcomputer design, and all workflows are controlled by software, which can achieve
high precision and high reliability.
7. The charging mode of high-efficiency MPPT is adopted to ensure that the battery works in the best state and greatly prolong the
service life of the battery.
8. It has full automatic control such as overcharge, overdischarge, overload protection, anti-reverse protection and so on
Attentions
The charge regulator is intended for use in photovoltaic systems with 12V or 24V nominal voltages, It shall be used
with vented or sealed (VRLA) lead acid batteries only.
Safety Recommendations:
1.Batteries store a large amount of energy. Never short circuit a battery whatever.
2.Batteries can produce flammable gases. Avoid making sparks, using fire or any naked flame. Make sure that the battery
room is ventilated.
3.Avoid touching or short circuiting wires and terminals. Be aware that the voltages on specific terminals and wires can
be up to double of battery voltage. Use isolated tools. Stand on dry ground and keep your hands dry.
Installation
232
MPPT
Solar Charge Controller
USER MANUAL
MPPT15060
50
205
87.5
Thank you very much for buying our product ,Please read
thoroughly before using the prouuct
Please installed in the room, avoiding direct-clearance,
do not install in the wet environment, when use it outdoor,
please install controller and batteries in the same place,
and the batteries installed in the same place, the controller
can measuring the battery temperature, charge
voltage regulation.
Attention:
1. Screws specifications M4
2. Make sure heat-location were not l blocke

Advertisement

Table of Contents
loading

Summary of Contents for OLYS MPPT15060

  • Page 1 MPPT Solar Charge Controller USER MANUAL MPPT15060 Thank you very much for buying our product ,Please read thoroughly before using the prouuct Description of Functions 1. Suitable for charging 12V/24V/36V/48V lead-acid batteries, including GEL, Sealed, Flooded battery 2. Mainly suitable for off-grid solar power generation systems, such as: home solar power generation system, solar RV power generation, boat, unattended base stations, outposts and so on.
  • Page 2 150mm space above and below the controller to ensure natural convection and heat dissipation. If installed. In a closed box, it is necessary to ensure reliable heat dissipation through the box. ■Grounding operation. MPPT15060 is a common positive design controller. The positive electrode of solar panel and battery can be grounded at the...
  • Page 3: Installation Instructions

    Installation instructions ! Warning 1.The wiring order must be in the prescribed order, first connect the battery, and then connect the solar panel. when you disconnect the controller you must first disconnect the solar panel. then disconnect the battery, and the two groups of solar panels are in no order.
  • Page 4: Icon Description

    Operation instruction Key function Forward or Increase Backward or Reduce Setting or Enter Load ON/OFF or Ese Icon description Solar panel voltage > light control voltage, which means daytime. Solar panel voltage > light control voltage, which means at night Charging, horizontal stripes rolling up dynamically Load ON Load OFF...
  • Page 5 Parameter setting operation In the battery voltage display interface, press the K3 button for 5 seconds to enter the parameter setting browsing interface (see < Parameter Settings Interface Browse >), and press K1 or K2 to cycle to the parameter interface you want to set. Short press K3 button (SET), display "SET"...
  • Page 6 Set load working mode There are 5 load working modes: 1: manual mode: press the K4 button to turn the load output on or off. 2: pure light control mode: the voltage of the solar panel is detected automatically, the load is turned on at dark and the load is turned off at dawn.
  • Page 7 Set real-time time Real-time time can be stored inside the controller, which can be kept consistent with the real time even if the controller is powered off, using load single-period control and dual-period control mode must be set to the correct real-time time. Real-time "SET","H"flash set hours...
  • Page 8: Led Status

    LED status Load status LED(Red) ON: Load on load status(red) OFF:Load off charge status (green) Charge status(green) ON: Charging OFF:no charging fasht flash:Charging at constant voltage slow flash: Floating charging Error code When the following error occurs in the controller, the E01-E08 error code is displayed, and the buzzer alarms synchronously, and the alarm continues until the error is corrected.
  • Page 9 RS485,RJ45 interface Temperature sensor(optional) -20℃-55℃ Working temperature 330mm×232mm 87.5mm × Demension Weight SHENZHEN OLYS COMPANY LIMITED Tel: 0086-755-29533796 E-mail: Kelly@olys-digital.com Address: 5 floor, B building of Sheng De Industrial Park,Lang Kou, Da Lang, Long Hua New district, Shenzhen City, China...

Table of Contents