Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III Safety instructions Dear user Please note! Congratulations on your purchase of a Faber fire! A It is advisable to always install a screen for the quality product from which you will experience fireplace if children, elderly or disabled people are warmth and atmosphere for many years.
C31, outlet via roof If desired, a 2 meter pipe set is available For a (flat) roof, use a Faber roof outlet with a (article number 20901530). diameter of 100/150mm. 3.2 False chimney C91, existing chimney ...
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III Preparation and installation Rough height adjustment: With the adjustable (optional) legs. instructions Accurate height adjustment: With the adjustable feet. 4.1 Gas connection The gas connection must comply with the Hanging on the wall applicable local standards.
Page 11
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III Ventilation For the height of the plateau, see point Correct ventilation prevents damaging overheating “N” (fig. 2.6 and 2.7). of the gas control block and its electronics and also Take into account a minimum distance of limits the temperature of the convection air.
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III 5.2 Side glass Checking the installation For cleaning only it’s not necessary to remove the side glass. Checking for gas leaks Check with a gas leak finder all connections and MatriX II and III: pipes for gas leakage.
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III Annual maintenance If the maximum lengths of the flue gas outlet is not exceeded. If possible, carry out a flue gas analysis Check (see section 7.2). Check and clean if necessary: ...
Page 14
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III 11 Flue calculation Elbows 90° in the horizontal plane: A simple way to calculate whether the exhaust Horizontal elbows are elbows entirely in configuration is possible in combination with your the horizontal plane fireplace, use the “Faber Flue App V2”:...
Page 21
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III 13 Calculation sheet Starter length (STL) First part on top of the appliance Value Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m...
Page 22
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III found value Search in the table at TVH and THL and enter the value that is found. ……………………………… If the detected value is a number, check whether the completed STL is higher or equal to the value in the table.
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III 14 Technical data 14.1 MatriX 800/500 I,II,III Technical data Type indication(s) MatriX 1050x500 I, II, III Matrix 800x500 I, II, III Type appliance C11/C31/C91 Diameter outlet/inlet 130/200 Gas connection 3/8" Indirect heating functionality...
Page 24
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III 14.2 MatriX 800/650 I,II,III Technical data Type indication(s) MatriX 1050x650 I, II, III Matrix 800x650 I, II, III Type appliance C11/C31/C91 Diameter outlet/inlet 130/200 Gas connection 3/8" Indirect heating functionality Category II2H3P...
Page 25
Installation manual MatriX 800/500 I,II,III and 800/650 I,II,III 15 Outlet position Please note! These rules apply only for the proper functioning of the unit, for ventilation and environmental protection you need to comply with the applicable rules as defined in the building regulations.