1. Safety Precautions Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating and main circuit for the model installed. ...
Page 3
WARNING 19. The unit is only for use in a closed portable water system. Utilization in an open water circuit or non-portable water circuit, may lead to excessive corrosion of the water piping and risk of incubating bacteria colonies, particularly Legionella, in water. 20.
2. Specifications WH-SXC09F3E8 WH-UX09FE8 Item Unit Outdoor Unit Performance Test Condition EN 14511 Condition A35W7 (Ambient/Water) 7.00 Cooling Capacity BTU/h 23900 kcal/h 6020 3.17 Cooling EER kcal/hW 2.72 Condition A7W35 A2W35 (Ambient/Water) 9.00 9.00 Heating Capacity BTU/h 30700 30700 kcal/h...
Page 5
Item Unit Outdoor Unit ø Three Power Source (Phase, Voltage, Cycle) Condition A35W7 A7W35 A2W35 (Ambient/Water) Input Power Cooling: 2.21 Heating: 1.86 Heating: 2.51 Maximum Input Power For Heatpump System 6.85 Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 3Ø...
Page 6
Item Unit Indoor Unit Volume Expansion Vessel Capacity of Integrated Electric Heater 3.00 Note: Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled indoor water inlet temperature of 12°C and water outlet temperature of 7°C. ...
Page 7
3. Features Inverter Technology - Energy saving High Efficiency Environment Protection - Non-ozone depletion substances refrigerant (R410A) Long Installation Piping - Long piping up to 30 meter with height difference 20 meter - Flexible 4-way piping for outdoor unit ...
4.1.4 Main Components (Only applicable for WH- Control panel S**09/12/14/16*9E8) Pressure relief valve Cabinet front plate Flow switch Cabinet Pressure gauge Handle (2 pieces) Water pump Overload protector 1 phase RCCB/ELCB Connector name (4 pieces) (Only applicable for Water Outlet Heater assembly WH-S**09*3E8) Gas Refrigerant...
5. Dimensions Indoor Unit <Top View> <Front View> <Side View> 35 98 107 115 155 <Bottom View> 205.5 98.5 Relative position between the indoor unit and the installation plate <Front View> 213.5 213.5 140.7 140.7 Installation 306.4 Plate Indoor unit external dimensions line Unit: mm...
6. Refrigeration and Water Cycle Diagram Outdoor Indoor Side Side Water Pressure Gauge Expansion Liquid Vessel Water Capillary Side Flow Expansion (3-Way Tube Switch Valve Strainer Strainer Valve) Subcooler Water Inlet (Connect Water Pipe Pump Sanitary Temp. Tank) Sensor Expansion Strainer Pipe Defrost...
14.5 How to Adjust Water Flow Rate [SERVICE MODE: 02] Before adjust the water flow rate, make sure that the total water volume in the installation is 50 litres minimum for heating side. The default setting is SPEED 3 (Only for WH-S**09*3E8 and WH-S**09/12*9E8) and SPEED 4 for WH- S**14/16*9E8.
18. Technical Data 18.1 Operation Characteristics 18.1.1 WH-SXC09F3E8 WH-UX09FE8 WH-SXC09F9E8 WH-UX09FE8 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 14.000...
Page 16
Cooling Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 10.000 9.000 8.000 7.000 6.000 5.000 Outdoor Temperature (°C) 5.500 4.500 3.500...
Page 17
Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 10.000 9.000 8.000 7.000 6.000 5.000 Piping Length (m) 3.000 2.500 2.000...
Page 18
Cooling Characteristics at Different Piping Length Condition Outdoor air temperature : 35°C (DBT), -°C (WBT) Indoor water inlet temperature : 12°C Indoor water outlet temperature : 7°C Piping length : 7 m 9.000 8.000 7.000 6.000 5.000 4.000 Piping Length (m) 2.500 2.400 2.300...
18.2 Heating Capacity Table 18.2.1 WH-UX09FE8 Water Out (°C) Input Input Input Input Input Input Capacity Capacity Capacity Capacity Capacity Capacity Outdoor Air (°C) Power Power Power Power Power Power 9000 3240 9000 3510 9000 3910 9000 4300 9000 4730 9000 5160 9000...