Industrial and commercial roller door operators (17 pages)
Summary of Contents for TdA PE200B
Page 1
High Speed Door Opener Installation and Users Manual WARNING ONLY QUALIFIED AND EXPERIENCED TECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT, OTHERWISE, SERIOUS PERSONAL INJURY, DEATH, OR PROPERTY DAMAGE MAY OCCUR. SAVE THESE INSTRUCTIONS. Total Door Automation (Australia) Pty Ltd www.totaldoorautomation.com.au sales@totaldoorautomation.com.au Technical Support 1800 AUSTDA (1800 287 832)
Contents 1. Introduction 2. Inspection 3. General Characteristic 4. Specifications • Specifications for Electronic Control System • Specifications for Motor 5. Operating Instructions • Basic Function • Control Key/Button • Install the stroke Controller 6. Safety Instruction 7. Maintenance 8. System Operation 9.
High Speed Door Servo Control System Introduction Thank you for choosing High Speed Door Servo Control System. Please read this manual carefully before you start to use the system. In this manual you will find instructions for how to set the operating code the control unit, malfunction diagnostics and debugging, and routine maintenance.
High Speed Door Servo Control System Inspection All product has passed inspection and testing before is leaving the factory. When you open the unit place make sure there is no damager during shipping. Also to confirm the equipment ratings are matching your requirement. General Characteristic Our servo control system is suitable for high speed PVC and aluminum doors.
High Speed Door Servo Control System Specification Specification for Electronic Control System Model PE200B PE500B PE700B Rated Output Power 0.75KW 1.5KW 2.2KW Supply Voltage AC 220 V±10% Speed Control Closed Loop Speed Contrlol Position Control Closed Loop Position Control Protective Function...
High Speed Door Servo Control System The system can operated via: 1) control box; 2) inching electronic control; 3) continuous automatic operation; 4) emergency stop; 5) single side operation box; 6) time delay; 7) radar and/or induction loops. Please refer to wiring terminal for eternal connections.
High Speed Door Servo Control System Stroke Controller utilizes absolute encoder. Connect the absolute encoder and reducer via encoder’s axle, and fix the wings on to the reducer, than insert the aviation plug into plug receptacle. 4. Safety 1) The motor and control unit MUST ground properly; 2) During the installation, commission and operation NO ONE is permit to stand under the door and stand in the operating path;...
Page 9
High Speed Door Servo Control System The mounting screw for the control unit must inspect regularly to prevent screw been getting loose and falling off. Check the internal and external wirings. Check and change the oil for the redactor on regular basis. Size 0.75KW Control Uint...
Page 10
High Speed Door Servo Control System 1.5KW Control Unit 2.2KW Control Unit...
Page 11
High Speed Door Servo Control System 0.75KW Motor 1.5KW Motor...
Page 12
High Speed Door Servo Control System 2.2KW Motor Absolute Encoder...
High Speed Door Servo Control System System Operation MAIN------ SERVO (dispaly) ┆ MODE: (mode) ┆ ┆ STATUS: (status) ┆ Info Mode ┆ (dispaly): Torque, Speed, Position. ┆ (mode): Manual, Auto, Jog. ┆ (status): OK, Opening, Closing, Falut, Stop, E-stop, Safty1, Safty2, Lock, Maintenance. ┆...
Page 14
High Speed Door Servo Control System ┆ ┆------1.Parameter ┆ ┆ ┆ ┆ ┆ ┆ Index Parameter Value Default ┆ ┆ Opening Speed 10-125 ┆ ┆ Closing Speed 10-125 ┆ ┆ Open Slowdown dis. 30-70 ┆ ┆ Close Slowdown dis. 30-70 ┆...
Page 15
High Speed Door Servo Control System ┆ ┆ ┆------2.Limit Switch Setting ┆ Select the limit switch type: ┆ ┆ ┆ ┆ Option Remaks ┆ ┆ Mechanical Limit Switch ┆ ┆ Absolute Encoder ┆ ┆ Proximity Switch ┆ ┆ ┆ ┆ Incremental Encoder Optional in debug mode ┆...
Page 16
High Speed Door Servo Control System ┆ ┆ ┆ ┆ Calibrate ┆ ┆ Failure ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆------3.RTC Config ┆ Configure the date and time of the real time clock. ┆...
Page 17
High Speed Door Servo Control System ┆------2.Contact Type ┆ ┆ Set the contact type. ┆ ┆ ┆ ┆ ┆ ┆ Index Parameter Value Default ┆ ┆ ┆ Ext E-Stop N.O / N.C ┆ ┆ ┆ Safety1 N.O / N.C ┆ ┆...
Page 18
High Speed Door Servo Control System ┆------4. Maintenance ┆ ┆ Set the work cycles before the next maintenance. ┆ ┆ ┆ ┆ ┆ ┆ Maintenance ┆ ┆ ┆ 0 Thousand ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ Save +...
Page 19
High Speed Door Servo Control System ┆ ┆------5.Language Set the system language. ┆ ┆ ┆ ┆ Language ┆ ┆ English ┆ ┆ ┆ ┆ ┆ ┆ Save ┆ ┆ ┆ ┆ ┆ ┆------6.Default Restore factory settings. ┆ ┆ ┆ Default ? ┆...
Page 20
High Speed Door Servo Control System ┆------2.Sum Counter ┆ Displays the work cycles. ┆ ┆ ┆ ┆ Sum Counter ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆ ┆------3.Maint Counter ┆ Displays the work cycles after maintenance. ┆ ┆ ┆...
Page 21
High Speed Door Servo Control System ┆------Err Shows the current error message. ERR 19 Absolute Encoder Failure...
High Speed Door Servo Control System Error Table: Error Code Content ERR01 Overcurrent ERR03 Under Voltage ERR04 Over Voltage ERR05 Over Voltage ERR06 Locked Rotor ERR07 Out Of Limit Position ERR08 EEPROM Failure ERR09 Over Speed ERR10 Motor Reversion ERR11 Overload ERR12 Sample Current Failure...
High Speed Door Servo Control System 0.75KW Port Table Port Function Remark AC220V input Braking resistor output + Braking resistor output - Motor brake + DC 96V Motor brake - Com/Gnd Manual open input Manual close input Manual stop input Emergency stop input DC24V+ Com/Gnd...
Page 24
High Speed Door Servo Control System 1.5KW&2.2KW Port Table Port Function Remark AC220V input Braking resistor output - Braking resistor output + Motor brake - DC 24V Motor brake + Reserved Safety input 1 NO (Safety edge, photocell, etc.), stop NO (Safety edge, photocell, etc.), reverse to open limit Safety input 2 when closing...