8 Measurements and Adjustments
8.1.
Introduction
When servicing this unit, make sure to perform the adjustments necessary based on the part(s) replaced.
To perform the adjustment, it is necessary to use the "SPCA5330_v1010.exe" and "CK26100WriteQRCodeTool.exe" software.
The Adjustment software "SPCA5330_v1010.exe" and "CK26100WriteQRCodeTool.exe" are available at "TSN Website".
8.2.
Matrix chart (Replaced part and Adjustment item)
The following matrix table shows the relation between the replaced part and the necessary adjustment.
When a part is replaced, make sure to perform the necessary adjustment(s) in the order indicated.
NOTE
1. Don't replace the sequence of the Adjustment because the previous calibration matters with the next adjustment.
8.3.
Adjustment procedure
8.3.1.
Read Lens QR Code
Since it is necessary to input later, read and note Lens QR
Code before assembly completion of the LZ20.