Page 3
Modular Conception Short Stack Motor Medium Stack Motor Long Stack Motor...
Page 4
22 mm OPP Hammer Durable 710 Watt Jam pot short stack motor housing 20 mm Ram 15,5 mm stroke wobble bearing...
Page 5
26 mm MPP Hammer durable 800 Watt jam pot medium stack motor housing 20 mm ram 18,9 mm strocke wobble bearing...
Page 6
28 mm HPP Hammer durable 900 Watt jam pot long stack motor housing non pumping 22 mm ram beat pice 22,0 mm strocke wobble bearing...
Page 7
New Range - Visual Differentiation 28mm 22mm 26mm Plastic rear Rubber grip Rubber grip handle rear handle rear handle Rubber grip Rubber grip side handle side handle Silver panel Side handle light...
Page 8
Before repair and service Follow the safety instructions...
Page 9
Before attempting any repairs, the following should be observed, Ensure that the correct tool is used and only use good quality hand tools Ensure the work shop is clean and tidy. Always wear protective clothing, Overalls, safety gloves, safety glasses, safety hat/net etc. Check condition of cord and plug.
Page 10
ENGLISH GERMAN ITALIAN FRENCH SPANISH PORTUGUESE DUTCH CHECK ÜBERPRÜFEN CONTROLLARE CONTROLER COMPROBAR VERIFIQUE CONTROLEREN ATTENTION ! ACHTUNG ! ATTENZIONE ! ATTENTION ! ATENCION ! ATENÇÃO! ATTENTIE ! TOURNEZ DANS LE GIRAR SENTIDO ANTI- TURN COUNTER DREHEN GEGEN GIRARE IN SENSO SENS INVERSE DES GIRO IZQUIERDA HORARIO...
Page 11
ENGLISH GERMAN ITALIAN FRENCH SPANISH PORTUGUESE DUTCH FUNKTIONSTEST PRUEVA DE TESTE DE FUNCTION TEST ESEGUIRE IL TEST TEST FONCTIONNEL FUNCTIETEST DURCHFÜHREN FUNCIONAMIENTO FUNCIONAMENTO LIMPIEZA DE PULIRE L’UTENSILE NETTOYEZ L’OUTIL CLEAN THE TOOL GERÄT REINIGEN LIMPE A FERRAMENTA REINIG HET TOESTEL HERRAMIENTAS SEND THE TOOL ENVIAR LA...
Page 12
High Voltage Test High voltage Test has to be carried out...
Page 13
Before repair and service Make sure the unit is in a electrical good condition like: - Power cable must be in good condition in order to avoid electrical injuries - High voltage test must be carried out in order to be sure the whole unit is in a electrical safe condition...
Page 14
Before repair HIGH VOLTAGE TEST MUST BE DONE VDE 0701 BVG A2 PROTECTION CLASS 2 (double isolation) 3sec 2500V PROTECTION CLASS 1 (earth wire): 3sec 1000V Earth wire examination up to 5 m <=0.3 Ohm per further 5m + 0.1Ohm...
Page 15
Before repair and service Check all functions of the unit : Tool Holder Mode Selector Switch (power cable is plugged in) Switch lock Front handle Hammer mechanism Spindle lock system...
Page 17
Before repair Understand the root cause Proper root cause analysis identifies the basic source or origin of your problem. Root cause analysis is a step by step approach that leads to the identification of a fault's first or root cause. Every system, equipment, or component failure happens for a reason.
Page 18
Durability of pneumatic hammers heavily depends upon CLEANLIESS during service...