This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright. No information contained herein may be copied, translated, transcribed or duplicated for any commercial purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics Co., Ltd.
Ver. Smart MBS RRH-P4 Installation Manual INTRODUCTION Purpose This manual describes procedure and method for installing Smart MBS RRH-P4. Document Content and Organization This manual consists of 2 Chapters, 6 Annex and Abbreviation as follows: CHAPTER 1. Before Installation This chapter introduces safety rules that must be understood for installing RRH-P4 and describes the configuration of RRH-P4.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual SAFETY CONCERNS The purpose of the Safety Concerns section is to ensure the safety of users and prevent property damage. Please read this document carefully for proper use. Symbols Caution Indication of a general caution...
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Caution CAUTION Power and Feeder line Caution for cleaning the Power Supply While cleaning the power supply device, take caution that the device does not come in contact with alien bodies that may cause power failure.
Page 11
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Caution when assembling the cable gland Ensure that all parts of the cable gland are assembled in the correct sequence. Incorrect assembly may result in influx of external air or moisture into the system and may cause corrosion, system malfunction and/or critical failure of the cooling system.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual TABLE OF CONTENTS INTRODUCTION Purpose ............................I Document Content and Organization ..................I Conventions ..........................II Revision History ......................... III SAFETY CONCERNS Symbols ............................V Warning ............................. VI Caution ............................. VII California USA Only ........................X CHAPTER 1.
Page 15
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Finishing connector connection with the tape ..............C-14 How to Shrink the Heat Shrink Tube .................. C-15 C.8.1 When assembling a connector to the feeder line ............C-15 C.8.2 When connecting a connector to another connector ..........C-17 ANNEX D.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 1.3 Cabling The following shows the cables connected to RRH-P4. [Rectifier] [UADU] [RF Antenna] 5) RET Cable 6) RF Cable 2) RRH-P4 Ground Cable [TGB] 1) TGB Ground Cable ※ TGB and Ground Kit are used in case of the 7/8 in. feeder line or more.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 1.4 Installation Precaution The following precaution must be observed to prevent accidents during RRH-P4 installation. Before Installation Install a high voltage warning sign near the area where high voltage cable is located.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Table 1.2 Minimum Allowed Cable Bend Radius Type Min. Allowed Cable Bend Radius Remarks GV/CV/FR-8 8 times of the cable external diameter 0.6/1 KV cable Optic Cable 20 times of the cable external diameter...
Page 29
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Cable Works The cable works require knowledge for the cabling works such as cable installation/binding. After Installation Cover the cable hole on the floor with a solid cover. Remove all installation residues; clean the area.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.3 Unpacking and Transporting This paragraph describes the work to unpack cabinets and other components and transport them to the place to be installed. The cabinet is externally packed and cabinet and other components are individually packed.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.4.1 Cable Gland Parts By loosening the gland nuts outside the unit, the cable gland is dissembled into 3 parts as shown in the picture below. (Except for system-side fixing parts) Cable Gland Nut...
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 4) Separate the rain protection filler from the cable gland body. [Separated rain protection filler] Rain Protection Filler 5) Install the cable by passing it through the cable gland nut from outside to inside.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.4.3 Checking and Assembling Unused Cable Gland Follow the instructions below to check and assemble the unused cable gland. The unused cable gland should not be disassembled, and be kept in the original factory configuration.
Page 41
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 C) Fix top bracket and bottom bracket (Attached to the RRH-P4) to the wall with M10 anchor bolt ass’y. M10 Anchor Bolt Top Bracket M10 Plane Washer M10 Spring Washer M10 Hex. Nut...
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.5.2 Fixing 1 Sector Pole Follow the steps below to fix the RRH-P4 to the pole. 1) Fix the top bracket and bottom bracket to the RRH-P4. (A~B) 2) Fix the RRH-P4 and bracket to the RRH-P4. (C) A) Place the bakelite-top 1, 2 and top bracket to the RRH-P4's top fixing holes and fix these firmly with insulation bushing, spring washer, plane washer and M8 ×...
Page 45
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Mounting Protection Cap on RRH-P4 Output Port Make sure to mount a protection cap on the output ports (ANT 0-3) when you putting up or down the RRH-P4. If you use the RRH-P4 without mounting a protection cap, it may cause damage...
Page 47
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 1) Install 1/2 inch feeders line from the RF port at the bottom of RRH-P4 to the RF antenna. 2) Insert a heat shrink tube (jelly type) to each end of the installed 1/2 inch feeder lines, then connect a Din type-male connectors to the RRH-P4’s RF port and the RF antenna...
Page 49
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Caution when Installing the RF antenna To protect from lightning, the RF antenna must be installed within the shielding angle as shown below, considering the downward distance and the angle from the tower lightning rod or the antenna pole lightning rod.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.6.2 Connecting RET cable Follow the steps below to connect the Remote Electrical Tilting (RET) cable used to control the tilting angle of the antenna from the distance. RET Connector (Amphenol or equivalent)
Page 53
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 - When 21 VDC volts are applied, the current supplied to the RET from RRH-P4 must be 1 A or lower. - The exterior of the RET connector must be made of metal without vent hole or other UL certified material.
Page 55
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Pressure terminal As for the pressure terminal or the cable, the UL Listed products or equivalent should be used. Ex) Manufacturer-Panduit RRH-P4: 6 mm Pressure Terminal (LCD8-14AF-L) When connecting the pressure terminal to a cable, remove the cable sheath where the pressure terminal is connected, and then push the cable all the way to the end of the cable lead-in part.
Page 57
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 C) Take the cable out of the box paying attention not to impact the junction box and the jumper cable. Be careful not to drag the jumper cable on the floor. Jumper Cable Junction Box D) Lay the hybrid cable on the floor.
Page 59
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 F) Fix the cable to the hoisting wire with a cable tie at regular intervals [within 3.28 ft (1 m)] to prevent impact or tension to the upper side of the junction box when lifting the hoist.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.8.2 Connecting DU Cabinet side cable If the length of the hybrid cable is inadequate for the installation: 1) Measure the hybrid cable’s excess length. (With a white marker pen, mark the area of the cable where the double-layer sheath will be peeled when positioned in the conduit fitting.)
Page 63
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 If the length of the hybrid cable is adequate for the installation: 1) For all power cables, leave 23.62 in. (600 mm) from where the double-layer sheath has been peeled off and cut the excess length off.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.8.3 Connecting RRH-P4 Power Cable When using the power cable (AWG8) Follow the steps below to connect the power cable to RRH-P4. 1) Unscrew the power window cover fixing screw located at the rear bottom of RRH-P4 using a Torx (T20) screwdriver.
Page 69
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Caution for installing the power cable To maintain cable gland’s rain protection performance, 11.81 in. (300 mm) or more interval should be kept straight. According to the radius of curvature of the cable specification should be considered.
Page 71
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 10) Insert power terminal protection cap to the installed power cable. 11) Align the pressure terminal of the power cable to the power terminal block for proper polarity and fix it with M5 screw.
Page 73
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 14) Close the power window cover after connecting power cable. And tighten the screws by torque 0.87 lbf.ft (12 kgf.cm) with torque driver (T20). Tighten the screws in order ...
Page 75
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Installing the Circuit Breaker To ensure stability in power supply, a circuit breaker must be installed on the power cable connected to the rectifier (or power distributor). Capacity of -48 VDC circuit breaker is 32 A.
Page 77
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2) Install one power cable (hybrid cable, AWG10, 2C) connected to the baseband rack’s DC SPD terminal to the RRH-P4 power terminal. (Refer to the ‘Caution for installing the power cable’). 3) Cut cable installed to the power terminal. Unsheathe outer cable sheath at 1.38 in.
Page 79
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Caution for installing the power cable To maintain cable gland’s rain protection performance, 11.81 in. (300 mm) or more interval should be kept straight. According to the radius of curvature of the cable specification should be considered.
Page 83
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 13) Insert the rain protection filler completely to cable gland body and fasten the cable gland nut by torque 2.17 lbf.ft (30 kgf.cm) using torque wrench. After fixing nut, confirm using the gap gauge that distance between cable gland body and nut is within 0.0 in.
Page 85
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Caution When Opening and Closing Power Window Cover Make sure to turn off the breaker connected to the RRH-P4 power before opening or closing the power window cover of the RRH-P4. If you open or close the power window cover when the breaker is turned on, it may cause damage to the system, or cause an electric short circuit resulting in severe injury.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.8.4 Connecting RRH-P4 CPRI cable Follow the steps below to connect the CPRI cable for the interface between RRH-P4 and UADU. 1) Unscrew the optic window cover fixing screw located at the front bottom of RRH-P4 using a Torx (T20) screwdriver.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.8.5 Hybrid Cable Shield Grounding Connection Follow the steps below to connect the shield ground cable of hybrid cable to the ground bar in the DU cabinet. 1) Install the shield ground cable of hybrid cable to the ground bar on the left of the DU cabinet.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 2.8.6 Remaining Hybrid cable Follow the steps below to organize the remaining cable after connecting the hybrid cable (power cable, CPRI cable) to RRH-P4. 1) Loop the excess length of the power cable and CPRI cable, and attach to the RRH-P4 fixing pole using a cable tie.
Page 97
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 4) Bind the spare cable to the pole with its waterproof cap facing up. Loop the remaining cable and bind it to the pole below the cap. Cable Tie Water proof Cap Pole...
Page 101
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Table 2.8 Construction Status Checklist (continued) Result Category Check Items Criteria Remarks Pass Fail Feeder Feeder Line installation and View, consistency, Line status fixing status bending ANT installation and Visual inspection connection status...
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual ANNEX A. Sector Antenna Installation A.1 Cautions when Installing a Sector Antenna Precautions of antenna installation are as follows. Sector antennas should be installed vertically. (±1°) Antenna is the precise material, so be careful not to make damage or form change.
Page 105
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Caution when Installing the RF antenna To protect from lightning, the RF antenna must be installed within the shielding angle as shown below, considering the downward distance and the angle from the tower lightning rod or the antenna pole lightning rod.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual ANNEX B. Feeder Line Work B.1 When installing the feeder, the cautions When installing the feeder, the following cautions shall be considered: Put a plate to work not to make damage for the surface of the feeder cable.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Table B.2 Curvature Radius of Feeder Cable for Indoor Specification Allowed Radius of Curvature Remark LS Feeder Line HFSC 6D 1/4 in. 0.98 in. (25 mm) Indoor HFSC 10D 3/8 in. 0.98 in. (25 mm) HFSC 12D 1/2 in.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 B.2 Antenna Feeder Cable Ground Ground the antenna feeder line using the grounding kit located under the Tower Ground Bar (TGB) installed in the lower section of the tower or in the antenna feeder line duct.
Page 113
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 7) Align the heat shrink tube, inserted when installing the feeder line, into the fixing part of the ground kit. - Heat shrink tube: Φ 1.65 in., 7.87 in (Φ 42 mm, 200 mm) 8) Shrink the heat shrink tube [jelly type, 7.87 in.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 B.3 Tower Ground Construction 1) Install a Tower Ground Bar (TGB) that will be used to ground a feeder cable onto the tower. If the height of the tower is more than 65.62 ft (20 m), two or more TGBs should be installed (onto the lower and upper sections of the tower).
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual ANNEX C. Assembling connector C.1 RJ-45 (Shield type) Below is the method for assembling the RJ-45 (Shield type) connector. 3) Pass the cable through the 1), 2) Prepare work tools and materials. marking tube.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 C.2 RJ-45 (Normal type) Below is the method for assembling the RJ-45 (Normal type) connector. 3) Remove a 0.67 in. (17 mm) 2) Insert the RJ-45 cap into the 1) Prepare work tools and length of the sheath.
Page 121
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 5) Push the N Type-male body into the end of the cable until it is solidly inserted to the pin connection part of the N Type-male body. Make the shield overlap over the N Type-male body. Then pull out the clamp ring and reset it to the original position to make the remaining shield folded.
Page 123
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 5) Push the TNC male body into the end of the cable until it is solidly inserted to the pin connection part of the TNC male body. Make the shield overlap over the TNC male body. Then pull out the clamp ring and reset it to the original position to make the remaining shield folded.
Page 125
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 3) Remove the end 0.43 in. (11 mm) of the external conductor using a trimming tool. Trimming Tool Collet 4) Insert the internal conductor into the deburring hole at the bottom of the trimming tool to trim it.
Page 127
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 7) Insert the heat shrink tube into the 1/2 in. feeder line fitted with the N type-male connector as shown in the figure below. - Heat shrink tube: Φ 1.1 in., 3.94 in. (Φ 28 mm, 100 mm) 8) Shrink the heat shrink tube inserted into the 1/2 in.
Page 129
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 5) Tighten firmly the clamping nut and Din type-male body inserted to the 1/2 in. feeder line using a wrench. The recommended torque for tightening the clamping nut and Din type-male body is 306~510 lbf·ft (30~50 N.m).
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 C.8 How to Shrink the Heat Shrink Tube C.8.1 When assembling a connector to the feeder line Below is the procedure for shrinking the heat shrink tube. 1) Prepare a 1/2 in. feeder line, heat shrink tube, and heating gun to finish the cable using a heat shrink tube.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 C.8.2 When connecting a connector to another connector Below is the procedure for shrinking the heat shrink tube. 1) Prepare a 1/2 in. feeder line, 7/8 in. feeder line, heat shrink tube, and heating gun to finish the cable using a heat shrink tube.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual ANNEX D. Cleaning Optic Connector D.1 Cleaning Optic Connector When connecting optical cable to the system, performance of system can be decreased or fails can occur if core section of optical connector is dirty due to dust or foreign material.
Page 139
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 D.2 IBC Brand Cleaner Method that uses IBC Brand Cleaner is as follows: D.2.1 IBC brand type cleaner (P/N 9393) Method that uses IBC Brand Cleaner (P/N 9393) for LC-LC and MU connector is as...
Page 141
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Optic Cable Connector Cleaning (LC type plug) 1) To clean the optic cable connector, open the guide cap cover from the cleaner (P/N: 9393). Outer Shell Nozzle Guide Cap Guide Cap Cover [IBC Brand Cleaner: P/N 9393] 2) Insert a cleaner guide cap to every core of the optic cable connector.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 E.3 Assembling Pressure Terminal The procedures for assembling a pressure terminal to a cable are as follows: Strip the Cable Sheath 1) After checking the inside length of a pressure terminal, mark the cable.
Page 149
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Checking When Using A Wire Stripper A wire stripper is used differently depending on its manufacturer or type. Therefore, refer to the user manual enclosed with the product. The specifications and cautions of a wire stripper described in this manual are as follows: ...
Page 151
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 5) After complementary of the cable which is temporary fixed, align it to the hole and firmly compress the pressure terminal to secure fix it. 6) Separate the pressure terminal from the handheld compressor. Press down the handle of compressor until a clicking sound is heard to be unlocked.
Page 153
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Fixing Pressure Terminal (Hydraulic Press) 1) Among the dies of the hydraulic press, select one that fits to the pressure terminal. Dies Hydraulic Press 2) Assemble the dies to the pressing area of the compressor.
Page 155
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual/Ver.3.0 Checking When Using a Hydraulic Press A hydraulic press is used differently depending on its manufacturer or type. Therefore, refer to the user manual enclosed with the product. The specifications and cautions of a hydraulic press described in this manual are as follows: ...
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual ANNEX F. Standard Torque When you fasten the bolt, refer to the standard torque value below to prevent the equipment and bolt from damage and fasten tightly. When the torque value for each connection part is defined already, refer to the defined value.
2600-00CTEIGAA Ver. Smart MBS RRH-P4 Installation Manual ABBREVIATION CDMA Code Division Multiple Access CPRI Common Public Radio Interface Direct Current Electromagnetic Compatibility Global Positioning Satellite In/Out Long Term Evolution Main Ground Bar Remote Electrical Tilting Radio Frequency RRH-P4 Remote Radio Head-PCS band 4Tx/4Rx...
Page 161
500cm during normal operation. The gain of the antenna is 18 dBi. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. ⓒ SAMSUNG Electronics Co., Ltd.