KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W Note: Because CONTENTS 2 to 7 are the extracts from the Operating Instructions of this model, they are subject to change without notice. Please refer to the original Operating Instructions for further information.
Page 3
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 10.2. Error Message Table 17.3. Charge Circuit 10.3. Check Record 17.4. Ringer and Handset SP-Phone 10.4. Check Playback 17.5. Sending Signal 10.5. Check Battery Charge 17.6. Reception Signal 10.6. Check Link 18 SIGNAL ROUTE 10.7.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 1 ABOUT LEAD FREE SOLDER (PbF: Pb free) Note: In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 1.2. How to recognize that Pb Free solder is used 1.2.1. Base Unit PCB 1.2.1.1. Main IC901 IC601 IC701 IC501 IC521 Marked (Component View) Marked IC201 IC300 IC301 (Flow Solder Side View) Note: The location of the “PbF“...
Page 6
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 1.2.1.2. Operation Marked (Flow Solder Side View) Note: The location of the “PbF“ mark is subject to change without notice. 1.2.2. Cordless Handset PCB IC204 IC201 IC901 IC202 IC203...
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 2 BATTERY 2.1. Standard Battery Life 2.1.1. Battery Charge 2.1.2. Battery Strength 2.1.3. Recharge Note for service: The battery strength may not be indicated correctly if the battery is disconnected and connected again, even after it is fully...
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 4.2. Troubleshooting (Handset LCD) The following will be displayed when the unit needs your attention.
Page 33
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 6.6.4. Editing an Item in the Phone Book 6.6.5. Erasing an Item in the Phone Book...
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 10 TROUBLESHOOTING GUIDE Cross Reference: Note: Check Power (P.42) (*1) When a user claims that the unit disconnects a call right after the greeting message and no incoming messages can Error Message Table (P.42)
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 10.1. Check Power Cross Reference: NOTE: Power Supply Circuit (P.70) DSP is IC501. Reset Circuit (P.72) 10.2. Error Message Table Display Symptom Remedy The initialization was tried, but it could not be done.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 10.3. Check Record c) How to change the Auto Disconnect activation (time) Some Telephone Company lines (fiber or cable) ON Hook and OFF Hook voltages are lower than conventional lines, which may cause a malfunction of Auto Disconnect detection.To solve this problem, try changing the Auto Disconnect activation (time)
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 10.7. Check the RF Part 10.7.1. Finding Out the Defective Part After All the Checkings or Repairing Re-register Handset (to be checked) to Base Unit (to be checked) and HS to BU Regular unit (working).
Page 47
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 10.7.2. RF Check Flowchart Each item (1a ~5) of RF Check Flowchart corresponds to Check Table for RF part. Please refer to the each item. Cross Reference: Check Table for RF part (P.48)
Page 48
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 10.7.3. Check Table for RF part Item BU checking HS checking 1a Link confirmation Normal 1. Re-resister HS Regular Unit (working) to BU. 1. Re-resister HS to BU of Regular Unit (working).
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 11 TEST MODE 11.1. Test Mode Flow Chart for Base Unit 11.1.1. TX Burst Mode and Adjust X’tal Mode...
Page 56
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 11.2.3. Test Link Mode Note: (*1) LCD displays the Channel number. (exception: default/ CH00 = 1ch.)
Page 57
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 11.2.4. Adjustment flow (X’tal mode and Batt Low Mode) Cross Reference (*1) Adjustment Battery Low Detector Voltage (Handset) (P.58) NOTE: (*2) These are the default values. (*3) These values may not be fixed depending on the battery strength.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 11.3. X801 (Base Unit), X201 (Handset) Check Equipment: Frequency counter Check Point for measurement: BCK Checking tolerance: 13.824MHz ± 100Hz 11.3.1. Check and Adjustment X801 (Base Unit) Frequency 1. Set up Base Unit in TEST mode.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 11.8. How to Clear User Setting The operation reset the unit to Factory setting. (Erase recording Voice messages, Stored phone numbers, Caller list and etc.) This operation should not be performed for a usual repair.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 12 DESCRIPTION 12.1. Frequency The frequency range of 2400MHz~2480MHz is used. Transmitting and receiving channel between base unit and handset is same frequency. Refer to the Frequency Table. 12.2. FHSS (Frequency Hopping Spread Spectrum) This telephone is using an IC chip which has similar specification to WDCT (World Digital Cordless Telephone) and is the cordless telephone system that can use multiple portable unit simultaneously.
Page 64
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 12.2.1. TDD Frame Format 12.2.2. TDMA system This system is the cycles of 10ms, and has four duplex paths, so it is possible to perform four duplex communications simultaneously.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 12.3. Signal Flowchart in the Whole System Reception CN101 of the base unit is connected to the TEL line, and signal is entered through the bridge diode D101. While talking, the relay (Q104) is turned ON and amplified at the Q150, then led to DSP (IC501).
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 13 EXPLANATION OF LINK DATA COMMUNICATION 13.1. Calling 13.2. To Terminate Communication 13.3. Ringing...
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 15 CIRCUIT OPERATION (Base Unit) General Description: (DSP, Flash Memory) is a digital speech/signal processing system that implements all the functions of speech compression, record and playback, and memory management required in a digital telephone answering machine.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 15.1.2. The Meaning of the Motion of Pin 100 • • • • The period of Host Power Up (Hardware Initialization) In this period, the host sets up some registers in order to wake up the system.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 15.3. Power Supply Circuit Function: The power supply voltage from AC adaptor is converted to the desired voltage of each block. Circuit Operation: • • • • IC301, Q301 and D303: 4.0V DCDC Converter •...
Page 71
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 15.3.1. Charge Circuit The voltage from the AC is supplied to the charge circuits. Normal charge of maximum 6-hours is started soon after the Handset is placed on the base unit. Then it changes to Trickle charge to prevent from overcharging.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 15.4. Reset Circuit Function: This circuit is used to initialize the microcomputer when it incorporates an AC adaptor. Circuit Operation: When the AC Adaptor is inserted into the unit, then the voltage is shifted by IC300 and power is supplied to the DSP.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 15.5. Locator Mode 1. Press the base LOCATOR button, then a beep is output from pins 29 and 31 of IC501, and blinks on the display [IN USE] (LED) is caused by IC501.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 15.7. Auto Disconnect Circuit Function: This circuit is used to detect the fact that another telephone connected to the same line is OFF-HOOK while the unit is in a receiving status or OGM transmitting status.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 15.8. Parallel Connection Detect Circuit Function: In order to disable call waiting and stutter tone functions when using telephones connected in parallel, it is necessary to have a circuit that judges whether a telephone connected in parallel is in use or not. This circuit determines whether the telephone connected in parallel is on hook or off hook by detecting changes in the T/R voltage.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 15.9. Calling Line Identification (Caller ID)/Call Waiting Caller ID Function: Caller ID The caller ID is a chargeable ID which the user of a telephone circuit obtains by entering a contract with the telephone company to utilize a caller ID service.
Page 77
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W Call Waiting Caller ID Calling Identity Delivery on Call Waiting (CIDCW) is a CLASS service that allows a customer, while off-hook on an existing call, to receive information about a calling party on a waited call. The transmission of the calling information takes place almost immediately after the customer is alerted to the new call so he/she can use this information to decide whether to take the new call.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 17 CIRCUIT OPERATION (Handset) 17.1. Construction The circuit mainly consists of DSP and RF unit as shown in the block diagram. 17.1.1. DSP:IC201 17.1.1.1. Function • • • • Battery Low, Power down defect circuit •...
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 17.3. Charge Circuit When the handset is put on the cradle of the Base unit or the optional charger, the power is supplied from CHARGE2 and CHARGE1 terminals to charge the battery via D205 (D207), R268, Q212. The voltage between CHARGE2 and CHARGE1 flows D213 ->...
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 17.5. Sending Signal The voice signal from the microphone input to DSP (42-43). CN203 is the headset jack. When the headphone is connected, the Q206 detect it. The input from the microphone of the handset (MIN, MIP) is cut and the microphone signal from the headset is input to DSP (39).
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 19 CPU DATA (Base Unit) 19.1. IC501 Description High High_Z Description High High_Z INT0 56 FLASH_RST High Middle NOT_RLY On Hook Off Hook 57 TX_OUT High BELL 58 MOD_EN...
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 22.3. Removing Solder from 22 HOW TO REPLACE A Between Pins FLAT PACKAGE IC 1. Add a small amount of solder to the bridged pins. 22.1. Preparation 2. With a hot iron, use a sweeping motion along the flat part of the pin to draw the solder from between the adjacent pads.
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 26 TERMINAL GUIDE OF THE IC´S, TRANSISTORS AND DIODES 26.1. Base Unit 26.2. Handset...
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 27 REPLACEMENT PARTS Ref. Part No. Part Name & Description Remarks PQBC10399Z1 BUTTON, MESSAGE AS-HB LIST PQHR11024Z LED LENS, CHARGE PQHR11025Z LED LENS, ANSWER ON Note: PQHR11023Z GUIDE, LED...
Page 93
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks D903 B0DCCD000011 DIODE(SI) R351 PQ4R10XJ120 D904 B0DCCD000011 DIODE(SI) R352 ERJ2GEJ391 DA101 MA147 DIODE(SI)
KX-TG2343F / KX-TG2343P / KX-TG2343W / KX-TGA233F / KX-TGA233P / KX-TGA233W 28 FOR SCHEMATIC DIAGRAM 28.1. Base Unit (SCHEMATIC DIAGRAM (Base Unit)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. 2. This schematic diagram may be modified at any time with the development of new technology.