Page 1
ORDER NO. KM40210969C2 Telephone Equipment KX-TSC10EXB / KX-TSC10EXC / KX-TSC10EXW Integrated Telephone System Black Version Blue Version White Version (for Europe) SPECIFICATIONS...
Page 2
2002 Kyushu Matsushita Electric Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law.
Page 6
4. SETTINGS 4.1. Connecting the Handset/Telephone Line Cord...
Page 7
- Use only a Panasonic Handset for KX-TSC10EXB/C/W. - Use only a telephone line cord included in the unit. - If your unit is connected to a PBX which does not support Caller ID services, you cannot access those services.
Shown in Fig —. To remove —. Remove —. Lower Cabinet Screws (2.6 × 12).........(A) × 5 FFC and Solder Main P.C. Board Main P.C. Board CPU P.C. Board CPU P.C. Board 7. TROUBLESHOOTING GUIDE Make sure batteries are installed for proper operation before troubleshooting. 7.1.
Page 15
7.2. Tone Dialing Problems (handset) 7.3. No Ringing Sound When Ring Signal is Input...
8. BLOCK DIAGRAM 9. CIRCUIT OPERATION 9.1. Bell Detector Circuit When the bell signal is input between T/R, the signal are outputted at the speaker via the following path: Tel line R1/C1 Pin 8 of IC2 Pin 5 of IC2 Ringer 9.2.
current flow through the circuit) and the following signal flow id for the DC loop current. T D101 Q102 Q108 R114 D103 D101 - The receiving signal flows: TEL line Q102 C405 C401 R401 Q401 Q403 Q404 H/S SP - The transmission signal flows Q422 R428 C427...
of this circuit assumes that a caller ID service contract has been entered for the circuit being used. The data for the caller ID from the telephone exchange is sent during the interval between the first and second rings of the bell signal. The data from the telephone exchange is a modem signal which is modulated in an FSK (Frequency Shift Keying) format.
Page 20
10.2. CPU DATA (IC801) 10.3. RINGER IC (IC2)
SCK terminal is input terminal of Serial Clock to control transmit and receipt between Master and Slave. 2. SDA SDA terminal is input terminal, to forward the address and the mutual data between Master Device and Slave Device the mutual. This terminal needs the pull-up resistance external because output circuit of SDA uses Open Drain.
Be certain each pin is located over the correct pad on the PCB. 2. Apply flux for all pins of FLAT PACKAGE IC. 3. Being careful to not unsolder the tack points, slide the soldering iron along the tips of the pins while feeding enough solder to the tip so that it flows under the pins as they are heated.
15. REPLACEMENT PARTS LIST 1. RTL (Retention Time Limited) The marking (RTL) indicates that the Retention Time is limited for this item. After the discontinuation of this assembly in production, the item will continue to be available for a specific period of time. The retention period of availability is dependant on the type of assembly, and in accordance with the laws governing parts and product retention.
Page 28
15.1. Unit 15.1.1. Cabinet and Electrical Parts Ref. No. Part No. Part Name & Description Remarks PQKM10569P2 CABINET, UPPER PS-HB (for KX-TSC10EXB) PQKM10569P3 CABINET, UPPER PS-HB (for KX-TSC10EXC) PQKM10569Y1 CABINET, UPPER PS-HB (for KX-TSC10EXW) PQBH10033Z2 BUTTON, HOOK ABS-HB (for KX-TSC10EXB)