Page 2
Leggere completamente questo manuale di istruzioni prima di iniziare l’installazione del prodotto. Il simbolo evidenzia le note importanti per la sicurezza delle persone e l’integrità dell’automazione. Il simbolo richiama l’attenzione sulle note riguardanti le caratteristiche od il funzionamento del prodotto. Read this instruction manual to the letter before you begin to install the product.
• conforms to the essential safety requirements of the following directives: 73/23/EEC and subsequent amendment 93/68/EEC. 89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC Additional note: This product underwent tests in a typical uniform configuration (all products manufactured by FAAC S.p.A.). Bologna, 01 December 2006 The Managing Director A. Bassi...
Rev. 01.2006 - Istallation Manual Page 4 INSTALLATION OF CONTROL UNIT Procedure for securing components in the water-tight enclosure: Secure the transformer to the water-tight enclosure in position (A) If you are using buffer batteries (optionals), secure the relevant support in position (B). Insert the batteries in the support.
Rev. 01.2006 - Istallation Manual Page 6 2.2.2 PRESENTATION OF THE BOARD DESCRIPTION OF TERMINALS TERMINAL BOARD CN1(power supply) Terminals “1-2” (VAC-VAC): Connect, to these terminals, the secondary winding wires arriving from the toroidal transformer. Power ON is indicated by the lighting up of LED DL1 "power". Terminals “3-4”...
Rev. 01.2006 - Istallation Manual Page 7 Terminals “14-18” (OPEN A-COM1): Normally open contact. Connect, to these terminals, any pulse generator (e.g. push-button, key selector, etc..) which, by closing a contact, generates a pulse for totally opening or closing the gate. The operation of this input is defined by dip-switch 3 - see paragraph 2.5.1. Terminals “15-18”...
Rev. 01.2006 - Istallation Manual Page 8 2.3 ELECTRICAL WIRING FOR BOARD AND MOTORS CASE: LEFT LEAF OPENS FIRST TOWARD THE INSIDE A) 230 Volt Mains power supply coming from the electrical panel of the dwelling. Protected by a differential switch or by a 10 Amp fuse. 3 x 1.5 mm line from the dwelling to the pilaster B) The terminal with fuse, inserted in the enclosure, is used for connecting the 230 V~ mains supply to the...
Page 9
Rev. 01.2006 - Istallation Manual Page 9 CASE: RIGHT LEAF OPENS FIRST TOWARD THE INSIDE A) 230 Volt Mains power supply coming from the electrical panel of the dwelling. Protected by a differential switch or by a 10 Amp fuse. 3 x 1.5 mm line from the dwelling to the pilaster B) The terminal with fuse, inserted in the enclosure, is used for connecting the 230 V~ mains supply to the...
Rev. 01.2006 - Istallation Manual Page 10 2.3.1 AN ESSENTIAL CONTROL If you are not using safety devices (photocell, pressure switch, edge, etc..) or pulse generators (push- button, key selector, etc..), make sure that cursors 6 and 7 on the dip-switch are disabled (position "ON"). If you decide to disable these commands, you do not have to jumper the input.
Rev. 01.2006 - Istallation Manual Page 11 2.4.1 CONNECTION OF (OPTIONAL) BATTERIES Terminals "+ BAT - BAT". Connect the 2 optional batteries to terminals "+ BAT - BAT". During normal operation, the control unit keeps the batteries charged. The batteries come into operation when the transformer does not supply power. During connection, respect the polarity indicated on the board.
Rev. 01.2006 - Istallation Manual Page 12 PROGRAMMING 2.5.1 PROGRAMMING THE OPERATING PARAMETERS The multi-function control board has a dip-switch (DP1) for programming the operating parameters. Dip-switch DP1 is used for setting various parameters, such as the operating logic, automatic closing, and enabling/disabling the safety devices, etc..
Rev. 01.2006 - Istallation Manual Page 13 2.5.3 PROGRAMMING OPENING, CLOSING TIMES AND GATE PAUSE During this stage, the control unit memory stores work time and any pause time. To access programming, follow the instructions below: Release the operators (see the instructions on the mechanical operators) and take the leaves to about halfway of the opening travel.
Rev. 01.2006 - Istallation Manual Page 14 2.5.4 OPERATING LOGICS AUTOMATIC LOGIC (DIP-SWITCH 2=ON / DIP-SWITCH 3=OFF PULSES GATE STATUS OPEN A OPEN B STOP PHOTOCELLS Closed Opens leaves and re- Partially opens the gate Disables OPEN commands No effect closes after pause time Open in pause Closes at once...
Page 16
Les descriptions et les illustrations du présent manuel sont fournies à titre indicatif. FAAC se réserve le droit d’apporter à tout moment les modifications qu’elle jugera utiles sur ce produit tout en conservant les caractéristiques essentielles, sans devoir pour autant mettre à...