KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS TABLE OF CONTENTS PAGE PAGE 1 Safety Precautions----------------------------------------------- 4 15.2. CPU Data (Handset) ------------------------------------ 84 1.1. For Service Technicians --------------------------------- 4 15.3. How to Replace the Flat Package IC --------------- 85 2 Warning -------------------------------------------------------------- 4 15.4. How to Replace the LLP (Leadless Leadframe 2.1.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 1 Safety Precautions 1.1. For Service Technicians • Repair service shall be provided in accordance with repair technology information such as service manual so as to pre- vent fires, injury or electric shock, which can be caused by improper repair work.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 2.2.1. Suggested PbF Solder There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu), or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufac- turer's specific instructions for the melting points of their products and any precautions for using their product with other materi- als.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 3 Specifications Note: • Design and specifications are subject to change without notice.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4 Technical Descriptions 4.1. US-DECT Description The frequency range of 1.92 GHz-1.93 GHz is used. Transmitting and receiving carrier between base unit and handset is same fre- quency. Refer to Frequency Table (P.64). 4.1.1. TDD Frame Format 4.1.2. TDMA system This system is the cycles of 10 ms, and has 6 duplex paths, but maximum duplex communication path is 5 because of dummy bearer use.
Page 8
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.1.3. Signal Flowchart in the Radio Parts Reception A voice signal from TEL line is encoded to digital data "TXDATA" by DSP (IC501) in a base unit. Then TXDATA goes to RF PART, and it's modulated to 1.9 GHz. The RF signal is amplified and fed to a selected antenna.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.4. Circuit Operation (Base Unit) General Description: (DSP, EEPROM) is a digital speech/signal processing system that implements all the functions of speech compression and memory management required in a digital telephone. The DSP system is fully controlled by a host processor DSP. The host processor provides activation and control of all that func- tions as follows.
Page 12
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.4.3. Power Supply Circuit Function: The power supply voltage from AC adaptor is converted to the desired voltage of each block. Circuit Operation: • Q300 and IC300: 4.0 V DCDC Converter • IC331: 3.3 V Regulator...
Page 13
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.4.3.1. Charge Circuit The voltage from the AC adaptor is supplied to the charge circuits.
Page 14
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.4.4. Reset Circuit Function: This circuit is used to initialize the microcomputer when it incorporates an AC adaptor. Circuit Operation: When the AC Adaptor is inserted into the unit, then the voltage is shifted by IC331 and power is supplied to the DSP.
Page 15
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.4.5. Telephone Line Interface Telephone Line Interface Circuit: Function • Bell signal detection • ON/OFF hook and pulse dial circuit • Side tone circuit Bell signal detection and OFF HOOK circuit: In the idle mode, Q141 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the Tip (T) and Ring (R) leads (When the telephone rings), the AC ring voltage is transferred as follows: T →...
Page 16
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.4.6. Parallel Connection Detect Circuit Function: In order to disable call waiting and stutter tone functions when using telephones connected in parallel, it is necessary to have a circuit that judges whether a telephone connected in parallel is in use or not. This circuit determines whether the telephone con- nected in parallel is on hook or off hook by detecting changes in the T/R voltage.
Page 17
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.4.7. Calling Line Identification (Caller ID) Function: The caller ID is a chargeable ID which the user of a telephone circuit obtains by entering a contract with the telephone company to utilize a caller ID service. For this reason, the operation of this circuit assumes that a caller ID service contract has been entered for the circuit being used.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.7. Circuit Operation (Handset) 4.7.1. Construction The circuit mainly consists of DSP and RF part as shown in the block diagram. 4.7.1.1. DSP: IC501 Function • Battery Low, Power down detect circuit • Ringer Generation • Interface circuit RF part, Speaker, Mic, LED, Key scan, LCD...
Page 21
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.7.2. Power Supply Circuit Voltage is supplied separately to each block.
Page 22
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.7.3. Charge Circuit When the handset is put on the cradle of the base unit, the power is supplied from CHARGE+ and CHARGE- terminals to charge the battery via R366 or Q361. The voltage between CHARGE+ and CHARGE- flows Q531 → pin 38 of IC501, where the charge is detected.
Page 23
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.7.5. Sending Signal The voice signal from the microphone is input to DSP (90, 91). Also the power for the microphone is supplied from DSP (92) and the power is turned OFF on standby. 4.7.6. Reception Signal The voice signal from the base unit is output to DSP (98). This signal is led to R435 and drives the speaker, and the other signal...
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.8. Circuit Operation (RF Part) General Description: RF part includes Transmitter and Receiver functions. Digital signals (Mainly voice data) that come from DSP, are modulated and are transmitted. On the other hand, received signals are demodulated and go out to DSP.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 4.9. Circuit Operation (Charger Unit) The voltage from the AC adaptor is supplied to the charge circuits. Main charge (180~250 mA at the Battery) of maximum 7- hours is started soon after the handset is placed on the charger unit. Then it changes to Trickle charge to prevent from over- charging.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 5 Location of Controls and Components 5.1. Controls 5.1.2. Handset 5.1.1. Base Unit 5.2. Display...
Page 29
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 6.2.3. Battery Level 6.2.4. Panasonic Ni-MH Battery Performance (supplied batteries) 6.2.2. Battery Charge Note for service: The battery strength may not be indicated correctly if the battery is disconnected and connected again, even after it is fully charged. In that case, by recharging the battery as mentioned above, you will get a correct indication of the battery strength.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 7 Operating Instructions 7.1. Programmable Settings 7.1.1. Programming by Scrolling through the Display Menus...
Page 31
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 7.1.2. Programming using the Direct Commands...
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 7.2. Dial Lock For Service Hint: *: If the current password is forgotten, refer to Dial Lock in Troubleshooting (P.34).
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 8 Test Mode 8.1. Adjustment and Test Mode Flow Chart 8.1.1. TX-CW Mode for Base Unit Note: (*1) When you check test mode, connect to the external Buttons because Base Unit has only LOCATOR key. Refer to Bottom View (P.76).
Page 38
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 8.1.2. Test Link Mode for Base Unit Note: (*1) When you check test mode, connect to the external Buttons because Base Unit has only LOCATOR key. Refer to Bottom View (P.76). (*2) Refer to Test Link Mode for Handset (P.42). If you can not proceed to the next step, refer to Registering a Handset to a Base Unit (P.49).
Page 39
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 8.1.3. Adjustment Mode for Base Unit Cross Reference Check and Adjust Frequency (Base Unit) (P.61) Note: (*1) When you check test mode, connect to the external Buttons because Base Unit has only LOCATOR key. Refer to Bottom View (P.76).
Page 40
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 8.1.4. TX-CW Mode for Handset Note: (*1) LCD displays the Channel number. (exception: default/ CH00 = 0ch.) (*2) Refer to Check Table for RF part (P.51).
Page 41
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 8.1.5. RX-CW Test Mode for Handset Note: (*1) LCD displays the Channel number. (exception: default/ CH00 = 0ch.) (*2) Refer to Check Table for RF part (P.51).
Page 42
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 8.1.6. Test Link Mode for Handset Note: (*1) LCD displays the Channel number. (exception: default/ CH00 = 0ch.) (*2) If can not proceed to the next step, refer to Registering a Handset to a Base Unit (P.49). (*3) for factory use only.
Page 43
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 8.1.7. Adjustment Mode for Handset Cross Reference (*1) Adjust Battery Low Detector Voltage (Handset) (P.61) Note: (*2) These are the default values. (*3) These values may not be fixed depending on the battery strength.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 9 Service Mode 9.1. How to Clear User Setting Units are reset to the Factory settings by this operation (Erase stored Phone numbers, Caller list and etc.). This operation should not be performed for a usual repair. 9.1.1. Handset Note: (*1) Be sure to short the battery terminals of the handset with a lead wire, etc.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10 Troubleshooting Guide 10.1. Troubleshooting Flowchart Cross Reference: Check Power (P.46) Check Battery Charge (P.46) Check Link (P.47) Check the RF part (P.48) Check Handset Transmission (P.55) Check Handset Reception (P.55) Check Caller ID (P.55)
Page 46
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10.1.1. Check Power Cross Reference: Note: Power Supply Circuit (P.12) DSP is IC501. Reset Circuit (P.14) (*1) Refer to Specifications (P.6) for part number and sup- ply voltage of AC adaptor. (*2) Refer to Circuit Board (Base Unit_Main) (P.75).
Page 47
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10.1.3. Check Link Cross Reference: Note: Check the RF part (P.48) DSP is IC501. (*1) Refer to Finding out the Defective part (P.48).
Page 48
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10.1.4. Check the RF part 10.1.4.1. Finding out the Defective part After All the Checkings or Repairing 1. Re-register the checked handset to the checked base unit, and Regular HS to Regular BU. Note: (*1) HS: Handset (*2) BU: Base Unit...
Page 49
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10.1.4.1.1. Registering a Handset to a Base Unit 10.1.4.1.2. Deregistering a Handset 10.1.4.1.3. Deregistering All Handsets by the Base Unit...
Page 50
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10.1.4.2. RF Check Flowchart Each item (1 ~ 6) of RF Check Flowchart corresponds to Check Table for RF part (P.51). Please refer to the each item. Note: (*1) Refer to Things to Do after Replacing IC or X’tal (P.61).
Page 51
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10.1.4.3. Check Table for RF part Item BU (Base Unit) Check HS (Handset) Check Link Confirmation Normal 1. Register Regular HS to BU (to be 1. Register HS (to be checked) to Regular checked). HS, BU Mode [Normal Mode] 2.
Page 52
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10.1.4.4. TEST RANGE Check Circuit block which range is defective can be found by the following check. Item BU (Base Unit) Check HS (Handset) Check Range Confirmation TX TEST 1. Register Regular HS to BU (to be checked). 1. Register HS (to be checked) to Regular BU.
Page 53
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10.1.4.5. RF-DSP Interface Signal Wave Form Control signal for Base Unit (Normal mode) Control signal for Base Unit (Normal mode) RADEOEN 2 ms SLOT_CTRL SYN_DATA SYN_CLK SYN_EN Zoom 1 µs 1 us 1 us 1 us SYN_DATA SYN_CLK SYN_EN...
Page 54
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS Base Unit TR-DATA Signal (Normal mode) Base Unit TR-DATA Signal (Normal mode) Base unit sends a dummy slot and receves all 6 slots every frame in normal mode. Pin Number (Base unit) ITEM MODE IC701 IC501 (BU) [HS] or [REG HS]...
Page 55
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 10.1.5. Check Handset Transmission Cross Reference: Signal Route (P.26) 10.1.6. Check Handset Reception Cross Reference: Signal Route (P.26) Note: When checking the RF part, Refer to Check the RF part (P.48). 10.1.7. Check Caller ID Cross Reference: Telephone Line Interface (P.15) Calling Line Identification (Caller ID) (P.17)
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 12 Measurements and Adjustments 12.1. Things to Do after Replacing IC or X’tal 12.1.1. Preparation Equipment: Frequency counter Check Point for measurement: BCK Checking tolerance: 13.824 MHz ± 100 Hz (Base Unit)/13.824 MHz ± 100 Hz (Handset) 12.1.2. Check and Adjust Frequency (Base Unit) 1.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 12.2. Base Unit Reference Drawing When connecting the simulator equipment for checking, please refer to below. 6.5 V Spectrum Analyzer ANT2-HOT POWER ANT1-GND ANT1-HOT ANT2-GND DCP2 C_DCM DCM2 C_DCP C-POWER BCLK BCLK Frequency Counter (*1) R612 R611 DVCC C612...
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 12.3. Handset Reference Drawing When connecting the simulator equipment for checking, please refer to below. Note: (*1) is referred to No.3 of Check Table for RF part (P.51).
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 13 Schematic Diagram 13.1. For Schematic Diagram 13.1.1. Base Unit (Schematic Diagram (Base Unit_Main)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. 2. The schematic diagrams may be modified at any time with the development of new technology.
Page 80
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 14.3.2. Bottom View R PbF KX-TGA93 PQUP11558Y LED557 LED556 LED555 LEFT MENU RIGHT TALK BACK NEXT PAUSE DOWN FLASH HOLD KX-TGA632 CIRCUIT BOARD (Handset_Main (Bottom View))
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 15.2. CPU Data (Handset) IC501 15.2.1. Description High High_Z 61 NC Normal Description High High_Z 62 NC Normal GNDPA 63 KEYSTROBE_E Active SPOUTP 64 KEYSTROBE_D Active BCLK 65 KEYSTROBE_C Active Normal 66 KEYSTROBE_B Active 67 KEYSTROBE_A Active XOUT 68 GND...
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 15.3. How to Replace the Flat Package IC 15.3.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700 °F ± 20 °F (370 °C ± 10 °C) Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less experience could overheat and damage the PCB foil.
Page 86
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 15.3.3. How to Install the IC 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 15.4. How to Replace the LLP (Leadless Leadframe Package) IC 15.4.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700 °F ± 20 °F (370 °C ± 10 °C) Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less experience could overheat and damage the PCB foil.
Page 88
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 15.4.4. How to Install the Shield Case Note: • If you don’t have special tools (ex. Hot air disordering tool), conduct the following operations. • Shield case’s No. : PNMC1002Z 1. Put the shield case. 2. Solder the surroundings.
Page 89
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 15.4.6. How to Install the IC 1. Place the solder a little on the land where the radiation GND pad on IC bottom is to be attached. 2. Place the solder a little on the land where IC pins are to be attached, then place the IC.
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 15.6. Terminal Guide of the ICs, Transistors and Diodes 15.6.1. Base Unit 15.6.2. Handset 15.6.3. Charger Unit...
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 16 Exploded View and Replacement Parts List 16.1. Cabinet and Electrical Parts (Base Unit)
(*1) This cable is fixed by welding. Refer to How to Replace the Handset LCD (P.60). (*2) Attach the SPACER (No. 124) to the exact location described above. (*3) The rechargeable Ni-MH battery (HHR-4EPT or HHR-4MPT) is available through sales route of Panasonic.
Page 99
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks R121 ERJ3GEYJ394 390k C308 ECUV1E104KBV 0.1 R122 ERJ3GEYJ394 390k C331 ECUV1A474KBV 0.47 R131 PQ4R18XJ106 C341 ECEA0JK331 R133 ERJ3GEYJ105 C342 ECUV0J105KBV 1...
Page 100
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks X501 H0J138500003 CRYSTAL OSCILLATOR (*1) IC373 C0DBAYY00067 IC IC374 C0EBD0000355 IC 16.5.2. Handset IC501 C2HBBY000097 IC (*1) IC541 PNWIG6381LBR IC (*1) 16.5.2.1.
Page 101
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks R543 ERJ2GEJ274 270k C743 ECUV1A105KBV 1 R561 ERJ2GEJ101 C751 F1G1H3R3A562 3.3p R572 D1BB4303A055 430k C752 ECUE1H100DCQ 10p R573 D1BB8203A055 820k C753...
Page 102
KX-TG6381LBB/KX-TG6381LBS/KX-TG6382LBB/KX-TGA632LBB/KX-TGA632LBS 16.5.4. Accessories and Packing Materials Note: (*1) You can download and refer to the Operating Instruc- tions (Instruction book) on TSN Server. 16.5.4.1. KX-TG6381LBB/LBS Safety Ref. Part No. Part Name & Description Remarks PQLV219LBZ AC ADAPTOR PQJA10075Z CORD, TELEPHONE...