for Compressor Start Device Kit for use on
EGY60, EGY70 & EMU60 Type Compressors Only
1.
Pull the refrigerator away from the wall; make sure to protect
the floor from any damage.
2.
Unplug refrigerator or disconnect power.
3.
On the rear of the refrigerator, remove the screws holding
the rear compartment cover in place. Remove the rear
cover. Set the screws and rear cover aside for reuse later.
(See Figure 1.)
4.
Remove the cover and all of the electrical components
from the compressor; pull them straight off of the compressor.
Disconnect from wire harness.
Note: Some models may have a plastic tie strap around
the PTC relay. Remove and discard the strap.
© Whirlpool Corporation 2006
(All Rights Reserved)
INSTRUCTION SHEET
Top Mount Refrigerators with
Kit Contains:
1 Instruction Sheet
1 PTC Start Relay
2 Overloads
1 Wire Jumper
1 Terminal Cover
1 Electrical Cover
FIGURE 1
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death
or electrical shock.
Tools Needed:
1 ¼" Nut Driver
1 Pocket Standard Screwdriver
5.
Identify the compressor type. See Figure 2.
EXAMPLE OF COMPRESSOR
TYPE NUMBER
FIGURE 2
Instruction Sheet 8201770 5/06