Page 1
ORDER NO. KM40306110C2 Telephone Equipment KX-TCD455GM / KX-A145EXM Digital Cordless Phone Metalic Gray Version (for Germany) SPECIFICATIONS...
Page 2
2003 Panasonic Communications Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law. 1. ABOUT LEAD FREE SOLDER (PbF: Pb free) Note: In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead.
Page 3
case of using high temperature soldering iron, please be careful not to heat too long. - PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100°F (600°C). - If you must use Pb solder on a PCB manufactured using PbF solder, remove as much of the original PbF solder as possible and be sure that any remaining is melted prior to applying the Pb solder.
Page 4
(Component View) (Flow Solder Side View) Note: The location of the “PbF“ mark is subject to change without notice. 1.2.2. Handset PCB (Component View) (Flow Solder Side View) Note: The location of the “PbF“ mark is subject to change without notice. 1.2.3.
Page 5
- When you replace the batteries, part should be removed first. 4.2. Battery Charge At the time of shipment, the batteries are not charged. To charge, place the handset on the base unit. Please charge the batteries for about 7 hours before initial use. During charging, the battery icon is as shown below.
Page 6
- Battery life is dependent on use and conditions but in general when using fully charged Ni-MH batteries (700 mAh): Talk time: 10hrs approx. Standby time: 120hrs approx. - When using Ni-Cd batteries (250 mAh): Talk time: 4hrs approx. Standby time: 40hrs approx. (Times indicated are for peak performance) - The batteries reach peak performance after several full charge/ discharge cycles.
Page 7
- Do not use non-rechargeable batteries. If non-rechargeable batteries are fitted and start charging, it may cause the leakage of the battery electrolyte. Please use only Panasonic P03P(Ni-MH) or P03H(Ni-Cd) batteries. 5. LOCATION OF CONTROLS 5.1. Base Unit 5.2. Handset 6.
Page 8
Plug in the AC adaptor and the telephone line cord in order 1, 2, 3, 4. The AC adaptor must remain connected at all times (It is normal for the adaptor to feel warm during use). - Never install telephone wiring during a lightning storm. 6.1.2.
Page 9
6.3. PIN Code 6.3.1. Base Unit - To exit the operation, press any time. For Service Hint: * : If the current 4-digit PIN is forgotten, press and you will be able to enter new PIN. 6.3.2. Handset...
Page 10
- To exit the operation, press any time. For Service Hint: * : If the current 4-digit PIN is forgotten, press and you will be able to enter new PIN. 6.3.3. Reset Base Unit PIN to Default (0000) -When There is NO Handset Registered- 6.3.3.1.
Page 11
1. Solder a pin or lead wire to GND, SDA, and SCLK on base PCB. 2. Plug in AC adaptor to the base. 3. Turn on the power to the JIG (9V). 4. Then connect the cable to each pins using clip. As for the connection between JIG and PCB, see below photos.
Page 12
Function Initial Setting Remarks (selectable options) Ringer Mode All Handsets All Handsets/Specific Handset Number of Rings Up to 6 rings Flash/Earth Flash Flash Timing 200 msec 80/200 msec Pause Timing 3 seconds 3 seconds/5 seconds Call Restricted Handsets All Clear Each Handset can be set indivisually.
Page 13
Function Initial Setting Remarks (selectable options) Time Alarm Mode OFF/ON Alarm Time Clear OFF/Once/Daily Handset Ringer Volume Handset External Ringer Pattern 20 patterns Handset Internal Ringer Pattern 20 patterns Handset Paging Tone Pattern 20 patterns Handset Alarm Tone Pattern 20 patterns Key Tone ON/OFF Call Waiting Tone...
Page 14
dialling buttons are locked. 6.6. Recall Feature RECALL is used to access special telephone services. Contact your Network provider for details. If your unit is connected to a PBX, pressing RECALL allows you to access some features of your host PBX such as transferring an extension call. 6.7.
Page 15
- To exit the operation, press any time. - *1: The factory preset is 0000. - *2: The selected handset number flashes. 6.9. Cancelling Call Restricted Handset(s) - To exit the operation, press any time. - *1: The factory preset is 0000. - *2: The selected handset(s) will stop flashing.
Page 16
6.12. Select Flash/Earth Mode An earth relay can be installed as an option depending on your PBX requirements. Please consult our Panasonic Service Centre for installation. On installation, you can select flash or earth mode to suit your PBX or Network provider.
Page 17
- To exit the operation, press any time. - *1: The factory preset is 0000. For Service Hint: Refer to Flash Time setting 6.13. Automatic Route Selection Automatic Route Selection is a feature which selects the least expensive carrier (network) service available, when making long distance calls.
Page 18
6.13.2. Storing the Area Code(s) Store the area code(s) for which the chosen carrier (network) service charge rates are lower than the original carrier (network) service. Up to 25 area codes can be stored. - To exit the operation, press any time.
Page 19
- To exit the operation, press any time. - *1: The factory preset is 0000. 6.14. Summary of Programmable Functions You can select and execute the following functions by pressing direct command as follows without programming. These operations need to be done with the Handset near the base unit. Press .
Page 20
7. DISPLAY 7.1. Handset Display 7.2. Before Requesting Help (Troubleshooting) If you experience any problems with the normal use of your apparatus, you should unplug it from the telephone outlet and connect a known working telephone in its place. If the known working telephone still has problems, then please contact the customer service department of your Network provider.
Page 21
Cross Reference: Power On/Off Call BAR On/Off (Call Prohibition On/Off)
Page 22
Key Lock Call Restriction 8. OPERATIONS 8.1. Power On/Off *1 When button is released, the display changes to the standby mode. *2 The display goes blank. 8.2. Making a Call *1 If you need to make a correction, press CLEAR. The digit is cleared to the left, then you can enter numbers.
Page 23
- To exit the operation, press any time. *1 You can enter the time in 12 hour clock or 24 hour clock. For example, to set 7:15 (12 hour clock), press 0715. If you enter the time in 24 hour clock, go to step 4. *2 If AM or PM is not selected, display will show 24 hour clock even if the time has been entered in 12 hour clock.
Page 24
- To exit the operation, press any time. *1 The display shows the number of phonebook space available. If is displayed, the phonebook is full. To store, clear other stored items in the phonebook. *2 If you need correction, press RIGHT or LEFT to move cursor then clear the character/digit by pressing CLEAR, and/or enter characters/digits.
Page 25
- To enter two characters located on the same dialling button, enter the first character and then press RIGHT to move the cursor on one space to enter the next character. 8.5.2. Finding Items in the Phonebook All phonebook items are stored in the following order: Alphabet Letter/Symbol/Number/ Telephone number (when a name is not stored).
Page 27
- To exit the operation, press any time. *1 If there is no item stored in the phonebook, the display shows *2 Characters are cleared to the left of the flashing character. *3 Characters are added to the left of the flashing character. If you need to clear or add more than one character, repeat the steps from 4.
Page 28
- To exit the operation, press any time. *1 If you need correction, press CLEAR. The digit is cleared to the left, then enter numbers. *2 If there is no item stored in the redial/caller ID list, the display shows *3 If you need to make a correction, press RIGHT or LEFT to move cursor then clear a character by pressing CLEAR, and/or enter characters.
Page 29
- To exit the operation, press any time. *1 If there is no item stored in the phonebook, the display shows *2 If an item is already stored to a hot key, will be displayed on the left of the key number.
Page 30
Caller ID. Note for service: There are two types of SMS; one is Type1 and the other is Type2. These types are different depending on the countries, and Type1 is assigned for KX-TCD455GM, KX-A145EXM.
Page 31
SMS is not available between a Type1 Handset and a Type2 Handset. 9.1. Writing and Sending New Messages...
Page 32
9.2. Reading/Displaying a Message in the Outgoing List 9.3. Sending/Editing/Clearing a Message from/in the Outgoing List...
Page 33
9.4. Receiving a Text Message 10. DISASSEMBLY INSTRUCTIONS 10.1. Base Unit Shown in Fig.- To Remove Remove Lower Cabinet Screws (2.6 × 12)..(A) × 2 Main P.C. Board Main P.C. Board 10.2. Handset...
Page 34
Shown in Fig.- To Remove Remove Rear Cabinet Screws (2 × 10)..(B) × 2 Rear Cabinet Follow the procedure. Main P.C. Board Screw (2 × 8)....(C) × 1 Screws (2 × 8).....(D) × 2 Main P.C. Board 10.3. Charger Unit...
Page 35
Shown in Fig.- To Remove Remove Lower Cabinet Screws (2.6 × 14)..(E) × 2 Main P.C. Board Main P.C. Board 11. ASSEMBLY INSTRUCTIONS 11.1. Warning When Constructing the Base Unit 12. TROUBLESHOOTING GUIDE Flow Chart...
Page 36
Cross Reference: Check Power Bell Reception Check Battery Charge Check Link Check Handset Transmission Check Handset Reception SIGNAL ROUTE 12.1. Check Power 12.1.1. Base Unit Is the AC Adaptor inserted into AC outlet? (Check AC Adaptor’s specification.) Cross Reference...
Page 37
Power Supply Circuit Note: BBIC is IC2. 12.1.2. Handset Cross Reference Power Supply Circuit/Reset Circuit Note: BBIC is IC1. 12.2. Check Battery Charge 12.2.1. Base Unit Cross Reference: Charge Circuit 12.2.2. Handset Cross Reference: Check Power Charge Circuit...
Page 38
Note: BBIC is IC1. 12.2.3. Charger Unit Cross Reference: Charge Circuit 12.3. Check Link 12.3.1. Base Unit Cross Reference:...
Page 39
Power Supply Circuit Adjustment (Base Unit) 12.3.2. Handset Cross Reference Power Supply Circuit Adjustment 12.4. Check Handset Transmission Cross Reference: SIGNAL ROUTE 12.5. Check Handset Reception...
Page 40
Cross Reference: HOW TO CHECK THE HANDSET SPEAKER SIGNAL ROUTE 12.6. Check Caller ID Cross Reference: SIGNAL ROUTE 12.7. Bell Reception 12.7.1. Base Unit Note: BBIC is IC2. 12.7.2. Handset Cross Reference: Telephone Line Interface Check Link Note: BBIC is IC1. 13.
Page 41
13.1.1. Equipment Required - DECT tester: Rohde & Schwarz, CMD 60 is recommended. - Frequency counter: it must be precise to be able to measure 1Hz (precision; ±4ppm). Hewlett Packard, 53131A is recommended. - DC power: it must be able to output at least 1A current under 9V. - Digital multi-meter (DMM): it must be able to measure voltage and current.
Page 42
See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00” to “FF” is read out. readid Read ID (RFPI) Type “readid”, and the registered ID is read out.
Page 43
14.2.1. Connections 14.2.2. PC Setting 1. Open a window of MS-DOS mode from the start-up menu. 2. Change a directory to the one with “RTX_COM” contained. 3. Type “SET RTX_COM=1” from the keyboard (when COM port 1 is used for the connection). 4.
Page 44
Symptom Remedy The base unit does not respond to a call from handset. Make adjustments in item (I)~(M) The base unit does not transmit or the transmit frequency is off. Make adjustments in item (H)~(J), (L) The transmit frequency is off. Make confirmation in item (H)~(J), (L) The transmit power output is low, and the operating distance between...
Page 45
Items Procedure* Check Adjustment Point 1. Confirm that the voltage between TP91 and GND is 4.0V ± 0.2V. 4.0V Supply D4,C40,Q9 Confirmation R41,R42,C4 D5,C69,C66 C67,L8,IC3 C65,C68,C6 1. Confirm that the voltage between J102 and GND is 2.65V ± 0.2V. VBACK Status IC2,Q8,C23 Confirmation C24,C25,C2...
Page 46
Items Procedure* Check Adjustment Point 1. Connect J1 (Telephone Socket) to Tel-simulator which is connected with 600 Hookswitch IC2,R7,R8, 2. Set line voltage to 48V at on-hook condition and line current to 40mA at off-hook Check with DC R9,R10,R77 condition of nomal telephone. Characteristics 3.
Page 47
Items Procedure* Check Adjustment Point Transmitted Remove the Antenna before starting step from 1 to 4. IC2,IC3,L1 1. Configure the DECT tester (CMD60) as follows; Power <Setting> Confirmation C43,C61,C6 -Test mode: FP -Traffic Channel: 5 C69,C48,C7 -Traffic Slot: 4 -Mode: Loopback -PMID: 0000 C66,C67,C6 -Set the Cable Loss as 5dB.
Page 48
Items Procedure* Check Adjustment Point Modulatoin Follow steps 1 to 3 of (H) above. IC2,IC3,L1 Check and 4.Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/ Adjustment C43,C61,C6 div using data type Fig31. 5.Adjust the B-Field Modulation if required. (Execute the C69,C48,C7 command "readmod"...
Page 49
Items Procedure* Check Adjustment Point (J) Frequency Offset Follow steps 1 to 3 of (H) above. IC2,IC3,L1 Confirmation 4.Confirm that the frequency offset is < ± 40kHz. C43,C61,C6 C69,C48,C7 C66,C67,C6 C57,C73,L3 DA1,R66,R6 C55,C56,R7 R79,C54,C5 C80,R38,C8 C82,C83,C8 C85,L8,C91...
Page 50
Items Procedure* Check Adjustment Point Sensitivity Follow steps 1 to 3 of (H) above. IC2,IC3,L1 Receiver 4.Set DECT tester power to -88dBm. Confirmation C43,C61,C6 5.Confirm that the BER is < 1000ppm. C69,C48,C7 C66,C67,C6 C57,C73,L3 DA1,R66,R6 C55,C56,R7 R79,C54,C5 C80,R38,C8 C82,C83,C8 C85,L8,C91...
Page 51
Items Procedure* Check Adjustment Point Timing Follow steps 1 to 3 of (H) above. IC2,IC3,L1 Confirmation 4.Confirm that the Timing accuracy is < ± 5.0ppm. C43,C61,C6 C69,C48,C7 C66,C67,C6 C57,C73,L3 DA1,R66,R6 C55,C56,R7 R79,C54,C5 C80,R38,C8 C82,C83,C8 C85,L8,C91...
Page 52
Items Procedure* Check Adjustment Point RSSI Level Follow steps 1 to 3 of (H) above. IC2,IC3,L1 Confirmation 4..Set DECT tester power to -88dBm. C43,C61,C6 5.Execute the command "readrssi". 6. Confirm: 23 < returned value < 45 (hex) C69,C48,C7 C66,C67,C6 C57,C73,L3 DA1,R66,R6 C55,C56,R7 R79,C54,C5...
Page 53
Items Procedure* Check Adjustment Point 1. Configure the DECT tester (CMD60) as follows; Receive Audio IC2,C21,R3 <Setting> Check and Adjustment -Test mode: FP C20,C11,R1 -Mode: Normal -PMID: 0000 2. Execute the command "testmode". R16,D3,R12 3. Initiate connection from DECT tester. 4.
Page 54
Items Procedure* Check Adjustment Point 1. Configure the DECT tester (CMD60) as follows; Transmit Audio IC2,R32,C2 <Setting> Check and Adjustment -Test mode: FP R23,C14,C1 -Mode: Normal -PMID: 0000 2. Execute the command "testmode". R22,R21,Q 3. Initiate connection from DECT tester. 4.
Page 55
Note: After the measuring, sock up the solder of TP. PC Setting () is required beforehand. The connection of adjustment equipment are as shown in Adjustment Standard (Base Unit) 15.2. Adjustment Standard (Base Unit) When connecting the Simulator Equipments for checking, please refer to below. 15.2.1.
Page 56
16. ADJUSTMENTS (HANDSET) If your unit have below symptoms, adjust or confirm each item using remedy column from the table. Symptom Remedy The movement of Battery Low indicator is wrong. Make confirmation in item (E), (F) The handset does not respond to a call from base unit. Make adjustments in item (G), (I)~(M) The handset does not transmit or the transmit frequency is off.
Page 57
Items Procedure* Check Adjustment Point 1. Confirm that the consumption current is < 200mA , that is, there is no short circuit. 4.0V Supply IC1,F1,R14 2. Confirm that the voltage between test point “+4V” and GND is 4.1V ± 0.2V. Confirmation R15,C53,C1 L1,D16,C4...
Page 58
Items Procedure* Check Adjustment Point 1. Stop supplying 6V to TP5(+) and TP6(-). Charge Detection IC1,C52,Q7 2. Execute the command "charge". (OFF) 3. Confirm that the returned value is 0x00 (hex). Confirmation Q8,R51,R1 C11,F1,R14 R15,C53,C 1. Apply 2.3V ± 0.005V between TP3(+) and TP4(-). Battery Monitor IC1,C52,Q7 2.
Page 59
Items Procedure* Check Adjustment Point Transmitted TP15 Remove the Antenna before starting step from 1 to 5. 1. Configure the DECT tester(CMD60) as follows; Power <Setting> Confirmation C111,C422 -Test mode: PP -RFPI: 0102030405 C423,C405 -Traffic Channel: 5 -Traffic Slot: 4 -Mode: Loopback R411,C408 2.
Page 60
Items Procedure* Check Adjustment Point Timing Follow steps 1 to 4 of (H) above. Confirmation 5.Confirm that the Timing accuracy is < ± 10ppm. C111,C422 C423,C405 R411,C408 C409,C401 C402,C403 RSSI Level Follow steps 1 to 4 of (H) above. Confirmation 5.Set DECT tester power to -88dBm.
Page 61
Items Procedure* Check Adjustment Point 1. Configure the DECT tester (CMD60) as follows; (O) Transmit Audio TP15 <Setting> Check and Confirmation -Test mode: FP C111,C422 -Mode: Normal -RFPI: 0102030405 C423,C405 2. Execute the command "testmode". 3. Execute the command "regcmd60". 4.
Page 62
Item Value Refer to -. * Remarks TX Power 20 dBm ~ 25 dBm Adjustment (Base Unit) Modulation 340 kHz/div ~ 402 kHz/ Data type: Fig31 Adjustment (Base Unit) Frequency Offset -40 kHz ~ +40 kHz Adjustment (Base Unit) RX Sensitivity <...
Page 66
21.3. Telephone Line Interface <Function> - Bell signal detection - Clip signal detection - ON/OFF hook circuit - Audio circuits Bell & Clip (: Calling Line Identification Presentation: Caller ID) signal detection: In the standby mode, Q2 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the TP3 (A) and TP40 (B) leads (when the telephone rings), the signal is transferred as follows;...
Page 67
21.4. Transmitter/Receiver Base Unit and Handset mainly consist of RF Module and DECT BBIC. Base Unit and Handset transmit/receive voice signal and data signal through the antenna on carrier frequency. Signal Pass: *Refer to SIGNAL ROUTE 21.4.1. Transmitter Block The voice signal input from the TEL LINE interface goes to RF Module (IC3) through DECT BBIC (IC2) as shown in BLOCK DIAGRAM (BASE UNIT) The voice signal passes through the analog part of IC2 where it is amplified and converted to a...
Page 68
EEPROM, LCD) - RF Module: IC10 - PLL Oscillator - Detector - Compress/Expander - Amplifier for transmission and reception 23.2. Power Supply Circuit/Reset Circuit Circuit Operation: When power on the Handset, the voltage is as follows; BATTERY(2.2 V ~ 2.6V: TP3) +4V(4V) IC10(6, 27), D20 IC1(35)
Page 69
The hands-free loudspeaker at SP+ and SP- is used to generate the ring alarm. IC4 is used to switch off the telephone loudspeaker and is used to amplify the signal to drive the hands-free loudspeaker. They are selected using the SP_AMP line from pin 69 of the BBIC. 2.5mm headset jack is also available.
Page 71
Descriptiojn Hi-z Remarks Data Bus D.I/O for Flash Memory PA_Driver_Amp PA-ON PA-OFF Data Bus D.I/O for Flash Memory TX/RX SW Data Bus D.I/O for Flash Memory RX Data Active Active Data Bus D.I/O for Flash Memory PLL Strobe Normal Latch Data Bus D.I/O for Flash...
Page 72
Descriptiojn Hi-z Remarks (NO USE) Bandgap Ref Differential Line for Bell Clip (NO USE) Differential Line for Bell Clip Audio In N (NO USE) ADC Ref RSSI (NO USE) for Polarity for Polarity (NO USE) PX.0 (I_PU) Address Bus for Flash Memory (NO USE) (I_PU)
Page 73
Descriptiojn Hi-z Remarks VBACK Address Bus for Flash Memory Address Bus for Flash Memory DSPIN/P1.O (Fixed) Address Bus for Flash Memory DSPOUT/P1.1 (Fixed) Address Bus for Flash Memory DSPCLK/P1.2 (Fixed) Address Bus for Flash Memory DSPFRM/P1.3 (Fixed) Read IC4 for Flash Memory Address Bus for Flash...
Page 74
27. CPU DATA (HANDSET) 27.1. IC1 (BBIC) Description Hi-Z Remarks Data Bus D,I/O for Flash Memory Address Bus for Flash Memory Address Bus for Flash Memory Address Bus for Flash Memory Address Bus for Flash Memory PA Driver Amp PA-ON PA-OFF TX/RX SW RX Data...
Page 75
Description Hi-Z Remarks CHARGE_START No Charge Charge for Charge VDDA VSSA LSRN LSRP Bandgap REF MICS MICP MICN Reference Voltage RSSI Headset DET Charge Current Charge Current DISCLK for LCD KEY STRB D,I/O Active KEY STRB D,I/O Active KEY STRB D,I/O Active Address Bus...
Page 76
Description Hi-Z Remarks Address Bus for Flash Memory Address Bus for Flash Memory VDDLI Address Bus for Flash Memory Address Bus for Flash Memory (NO USE) Back Light LED ON LED OFF SP Phone LED LED ON LED OFF Address Bus for Flash Memory Address Bus...
Page 77
28. EEPROM LAYOUT (BASE UNIT) 28.1. Scope The purpose of this section is to describe the layout of the EEPROM (IC1) for the KX-TCD455 Base Unit. The EEPROM contains hardware, software, and user specific parameters. Some parameters are set during production of the base e.g. crystal frequency adjustment at address 0000 and 0001, some are set by the user configuration e.g.
Page 78
Address Default Name Type Description Country Setting 0000-01 00 E0 EepromOscillator Frequency adjustment 0002 ModulationDeviation Modulation adjustment 0020 RFPI (ID for Base Unit) RFPI 0025 00 00 AC (Base PIN code) AC code 0028 TBR22Test TBR22 test 0030-0034 FF .. FF IPUI_1 (ID for H/S 1) Ipui for handset 1.
Page 79
Address Default Name Type Description Country Setting 09F1 Handset registration info - registration HsRegInfo.RegFlags 1=reg, 0=no reg 09F2 Handset registration info - EMC flags HsRegInfo.EmcFlags 6..7: not used 0..5: handset 1..6 info, 1=known , 0 unknown 09F3 RingMode Ring mode. Modes used in KAMMA4 20h and 21h.
Page 80
Address Default Name Type Description Country Setting 0F1C Detect CLIP detect configuration 0-2: Mode: 0: Learn mode, 1: only, 2: FSK only, 3: Generic Russian CLIP only 3: Unused4 4: Onhook: 1=enable 0=disable 5: Offhookk: 1=enable 0=disable 6: Msgwaiting: 1=enable 0=disable 7: Unused7 0F37..38 3D 01...
Page 82
29.2. Introduction The handset uses a 64k bit serial EEPROM (IC3) for storing volatile parameters. All parameters are set up before the handset the factory. Some of these are vital for the operation of the hardware so a set of default parameters is programmed before the actual hardware fine-tuning can be initiated.
Page 83
Address Default Name Type Description 0000-0001 EepromOscillator Frequency adjustment 0002 ModulationDeviation Mudulation adjustment 0030-0034 IPEI (ID for Handset) IPEI 0036-003A PARK_1 (ID for Base 1) PARK for registration 1 003B-003F PARK_2 (ID for Base 2) PARK for registration 2 0040-0044 PARK_3 (ID for Base 3) PARK for registration 3 0045-0049...
Page 84
Address Default Name Type Description 0136 LAL_2 Location area level for registration 0137 IPUI_LEN_2 IPUI length for registration 2 0138-0144 IPUI_2 - IPUI_14 IPUI for registration 2-14 0145 ZAP_2 ZAP for registration 2 0146 STATUS_2 Status for registration 2 0147-0156 UAK_2 - UAK_17 UAK for registration 2-17 0160-0164...
Page 85
Address Default Name Type Description Country Setting 02AC FactoryLanguageSetting 00 Factory setting for language: 00 = German 01 = English 02 = Welsh 03 = Croatian 04 = Spanish 05 = Norwegian 06 = French 07 = Italian 08 = Danish 09 = Dutch 0A = Swedish 0B = Finnish...
Page 86
Address Default Name Type Description Country Setting 02B0 Bit 0: 0:Disable, 1:Enable Russian AvailableLanguages Bit 1: 0:Disable, 1:Enable Polish Bit 2: 0:Disable, 1:Enable Slovakian Bit 3: 0:Disable, 1:Enable Czechs Bit 4: 0:Disable, 1:Enable Basque Bit 5: 0:Disable, 1:Enable Catalan Bit 6: 0:Disable, 1:Enable Gallego Bit 7: 0:Disable, 1:Enable Irish 02F1 00 - Reciever volume will be reset...
Page 87
Address Default Name Type Description Country Setting 1F07 ReceiveGainLowOffset x Bit7 - AOG Bit6 - AOG2 Bit5 - bit0: Gain-receive for volumestep offset to volumestep 2 (GR-Index) ranging from 0x00 to 0x24, each step representing 1 dB) 1F08 ReceiveGainHighOffset x Bit7 - AOG Bit6 - AOG2 Bit5 - bit0: Gain-receive for volumestep...
Page 88
Be certain each pin is located over the correct pad on the PCB. 2. Apply flux to all of the pins on the IC. 3. Being careful to not unsolder the tack points, slide the soldering iron along the tips of the pins while feeding enough solder to the tip so that it flows under the pins as they are heated.
Page 94
35. TERMINAL GUIDE OF THE ICs, TRANSISTORS AND DIODES 35.1. Base Unit...
Page 95
35.2. Handset 35.3. Charger Unit 36. REPLACEMENT PARTS LIST 1. RTL (Retention Time Limited) Note: The marking (RTL) indicates that the Retention Time is limited for this item. After the discontinuation of this assembly in production, the item will continue to be available for a specific period of time.
Page 96
2. Important safety notice Components identified by the mark indicates special characteristics important for safety. When replacing any of these components, only use specified manufacture’s parts. 3. The S mark means the part is one of some identical parts. For that reason, it may be different from the installed part.
Page 110
CHG terminal is properly fit in the cabinet. CHG terminal comes out of rib by pulling black lead wire when opening the cabinet and turning the PCB over. The terminal cannot have enough elastic force, cannot have good contact with handset, and it will result in charge problem.
Page 111
AF Volt Meter Tel Simulator DECT tester CMD60 (N) (O) (H) (I) (J) (K) (L) AF Generator JMP5 A201 JMP6 JMP7 JMP2 JMP4 JMP3 JMP1 JMP8 A202 R1 R6 R2 R4 B C E TP189...
Page 112
Digital Volt Meter (D) (E) (F) (G) 12Ω/2W (H) (N) (O) Digital Digital To PC (JIG) Volt Meter Volt Meter TP82 TP187 CHARGE CHARGE TP84 TP85 TP97 TP50 TP45 TP188 TP91 Frequency TP89 TP40 Counter TP39 TP101 TP90 DTMF tester Digital (F) (N) (O) Volt Meter...
Page 127
LED17 TALK LED3 LED13 BOOK LED14 PHONE LEFT LED2 REDIAL DOWN LED12 LED11 RIGHT LED1 PROG CANCEL POWER KX-A145EXM CIRCUIT BOARD (HANDSET) Flow Solder Side View...