Summary of Contents for Omicron HUMITEMP

  • Page 1 HUMITEMP® INTERNET OF THINGS INTELLIGENT DEVICE FOR REMOTE MONITORING For LoRaWan™, Sigfox, and Wi-Fi Networks Quick Start Guide omicroniot.com June 2023...
  • Page 2 Version control The following table contains the record of changes per manual version. Version Date Description 20/03/2023 Format change. Extensive revision and correction of content. Technical background information update. 24/06/2023 Version control implemented. Device image changed. omicroniot.com June 2023...
  • Page 3 If you encounter a problem with your Humitemp®, review the configuration information to verify that your selections are consistent with your application: input configurations; chosen limits;...
  • Page 4 Warning notice standard This guide contains notices that must be observed in order to ensure personal safety, prevent damage to properties, and guarantee proper installation, use, and maintenance of the equipment. The notices referring to personal safety or the integrity of the device are highlighted in the guide by an alert symbol;...
  • Page 5: Table Of Contents

    Contents Section 1: Introduction 1.1 Product recycling / disposal 1.2 Storage and transport Section 2: Quick Start 2.1 Connect the external sensors 2.2 Power the device 2.3 Turn on the device 2.4 Send data wirelessly 2.4.1 Enter the service mode 2.4.2 Connect the device to a Wi-Fi®...
  • Page 6 Equipment ratings and certifications are no longer valid on any products that have been damaged or modified without the prior written permission of Omicron IoT Solutions. Any continued use of a product that has been damaged or modified without prior written authorization is at the customer's sole risk and expense.
  • Page 7: Section 1: Introduction

    Section 1: Introduction This Quick Start Guide is designed to start or verify the proper operation of Humitemp® devices. These devices have an internal sensor to measure the Ambient Temperature and Relative Humidity; as well as 2 ports for submersible temperature sensors, or for digital sensors that detect the opening of doors.
  • Page 8: Section 2: Quick Start

    2.2 Power the device The Humitemp® is powered by 2 AA batteries (not provided by the manufacturer) or a MicroUSB power cable. The batteries are inserted into the battery box at the back of the device.
  • Page 9: Send Data Wirelessly

    2 seconds. The device will confirm the entry to the Service Mode by displaying the expression 'rEd' on its screen. While being in the Service Mode, the Humitemp® device generates a temporary Wi-Fi® network using its built-in Wi-Fi® module, named "IoTDevice_", followed by the device ID (e.g., "IoTDevice_bcddc212345").
  • Page 10: Connect The Device To A Wi-Fi® Network

    1. On the General Setup Page (Figure 2-2), press the Configure Wi-Fi button to go to a page where you can see a scan of the Wi-Fi® networks detected by the Humitemp®, two fields to enter data, and two buttons (Save and Scan).
  • Page 11: Mount The Device

    Figure 2-4 Waiting page for the connection to the Wi-Fi® network If the entered credentials are not correct, after pressing the "WiFi Results" button, the following page will appear: Figure 2-5 Wi-Fi® configuration page invalid Otherwise, you will see: Figure 2-6 Wi-Fi® configuration page correct After this, if desired, you can exit the Service Mode as described in 2.4.1.
  • Page 12: Login To The Remote Monitoring Platform

    2. Use the cable clamp and strap supplied with the instrument to secure the external sensor cables as shown in the picture below: Figure 2-7 Humitemp® wall mounting. Securing the cables this way prevents the manipulation of the sensors from generating tension or dangerous bending near the connector, which minimizes the risk of them coming out or being damaged;...
  • Page 13: Review The Device Dashboard In The Remote Monitoring Platform

    2.7 Review the device dashboard in the Remote Monitoring Platform After logging into the remote monitoring platform offered by the Humitemp® manufacturer, you can review the information sent by your device on its single Dashboard. To do this, login to the platform, go to 'Dashboards' (1, in Figure 2-9); then enter the list of Dashboards (2, in Figure 2-9) and select the Dashboard with your device ID (3, in Figure 2-9).
  • Page 14 Global Headquarters America Regional Office Omicron IoT Solutions Address: La Amalita Km4 Llanogrande-Rionegro Mall Plaza del Sol Off. 202 Rionegro, Antioquia, Colombia. Phone: +57 (604) 4087542 WhatsApp +57 (317)4365062 comercial@omicroning.co www.omicroniot.com omicroniot.com June 2023...