hit counter code
Download Print this page
ABB E260-16-10 Quick Start Manual
ABB E260-16-10 Quick Start Manual

ABB E260-16-10 Quick Start Manual

Electronic latching relay

Advertisement

Quick Links

9AKK108467A1173
REV A 12.2022
E260-16-10
https://id.abb/2CCG000981R0001
E260-16-20
https://id.abb/2CCG000972R0001
ABB Switzerland Ltd
Electrifi cation business
Smart Buildings Division
Fulachstrasse 150
CH-8201 Schaff hausen
Phone: +41 58 586 41 11
Fax: +41 58 586 42 22
new.abb.com/low-voltage
© Copyright 2022 ABB
Switzerland Ltd. All rights
reserved. Specifi cation subject
to change without notice.
200W/230V
LED
100W/110V
Elektronischer Stromstoßschalter
DE
I. Beschreibung
1. Klemmen der Ausgangskontakte (3-4)
2. Steuereingangsklemmen lokal (A1;A2)
3. Steuereingangsklemmen lokal für Anschluss mit Glimmlampe ( )
4. Klemmen der Ausgangskontakte (1-2)
II. Schaltbild
Steuerspannung AC 230 V (mit oder ohne Glimmlampe bis
a
zu 6 mA)
b
Universelle Steuerspannung AC/DC 8-240 V (ohne Glim-
mlampen)
Dieses Produkt ist nicht für die Motorsteuerung vorgesehen.
III. Funktionen der Steuereingänge
Eingang (A1)
jede Aktivierung des lokalen Steuereingangs
ändert den Zustand des Relais (Universalsteuer-
spannung AC/DC 8-240 V)
Eingang ( )
lokaler Steuereingang lokal funktioniert gleich
wie A1 (Steuerspannung AC 230 V)
IV. Prioritäten der Steuereingänge
Gleichzeitige Aktivierung der beiden lokalen Steuereingänge
(Potentiale) ist nicht erlaubt.
Warnung
Der sichere Betrieb des Produkts ist gewährleistet, wenn die Installati-
onsarbeiten gemäß dieser Gebrauchsanweisung durchgeführt wurden.
Jegliche Reparaturen oder Veränderungen des Gerätes sind nicht zuläs-
sig.
Anschluss- und Demontagearbeiten dürfen nur von autorisierten und
qualifi zierten Personen durchgeführt werden.
Defekte Produkte müssen als gefährlicher Abfall behandelt und entspre-
chend entsorgt werden.
Nationale oder regionale Vorschriften zum Umgang mit gefährlichen Ab-
fällen sind zu beachten.
WARNUNG! Installation darf nur von einer Person mit
elektrotechnischer Ausbildung durchgeführt werden.
I.
3
4
-A1
+A2
1
2
*
Incandescent
lamps (AC1)
Electronic latching relay
EN
I. Description
1. output contact terminals (3-4)
2. local control terminals (A1;A2)
3. local control terminal ( )
4. output contact terminals (1-2)
II. Connection
a
Control voltage AC 230 V (with or without glow-lamp up to
6 mA)
b
Universal control voltage AC/DC 8-240 V (without glow-
lamp)
This product is not intended for motor control.
III. Control input function
terminal (A1)
terminal ( )
IV. Control input priorities
The simultaneous activation of both local control inputs (po-
tentials) is not permitted.
Warning
The safe operation is assured if the assembly work has been carried
out according to these user instructions.
Any repair or modifi cation measures to the devices are not permitted.
Connection and removal work should only be carried out by author-
ised and qualifi ed persons.
Faulty products should be treated as hazardous waste and disposed of
in an appropriate manner.
National or regional regulations regarding the disposal of hazardous
waste should be adhered to.
Warning! Installation by person with electrotechnical
expertise only.
1
2
3
4
*
ECG, VVG
4000W
each activation of the local control input changes
the relay state (universal control voltage AC/DC
8-240 V)
local control input works the same as A1 (control
voltage AC 230 V)
II.
E260-16-10
a
E260-16-20
a
*
500VA
Halogen lamps
Elektronische impulsschakelaar
NL
I. Beschrijving
1. klemmen van de uitgangscontacten (3-4)
2. klemmen van de besturingsingangen local (A1;A2)
3. klem van de besturingsingang local ( )
4. klemmen van de uitgangscontacten (1-2)
II. Aansluiting
a
Stuurspanning AC 230 V (met of zonder glimlamp tot 6 mA)
b
Universele stuurspanning AC/DC 8-240 V (zonder glimlam-
pen)
Dit product is niet bedoeld voor het besturen van motoren.
III. Functie van de stuuringangen
terminal (A1)
elke activering van de stuuringang verandert de
status van het relais (universele stuurspanning
AC/DC 8-240 V)
terminal ( )
de stuuringang local functioneert op dezelfde
wijze als A1 (stuurspanning AC 230 V)
IV. Prioriteiten van de stuuringangen
Gelijktijdige activering van beide stuuringangen (potentialen)
local is niet toegestaan.
Waarschuwing
Een veilige werking van het product is gegarandeerd als de mon-
tagewerkzaamheden uitgevoerd zijn in overeenstemming met deze
gebruiksaanwijzing.
Geen reparaties en aanpassingen van de apparatuur zijn toegestaan.
De aansluit- en demontagewerkzaamheden mogen alleen worden uit-
gevoerd door geautoriseerde en gekwalifi ceerde personen.
Defecte producten dienen behandeld te worden als gevaarlijk afval en
op geschikte manier worden verwijderd.
Nationale of regionale voorschriften met betrekking tot het behande-
len van gevaarlijk afval moeten in acht worden genomen.
Waarschuwing! De installatie kan alleen uitgevoerd
worden door een persoon met deskundigheid op het
gebied van elektrotechniek.
b
b
* Ipeak < 70A, 10ms
*
1000VA

Advertisement

loading

Summary of Contents for ABB E260-16-10

  • Page 1 Fulachstrasse 150 CH-8201 Schaff hausen Phone: +41 58 586 41 11 Fax: +41 58 586 42 22 new.abb.com/low-voltage © Copyright 2022 ABB Switzerland Ltd. All rights reserved. Specifi cation subject to change without notice. * Ipeak < 70A, 10ms 200W/230V...
  • Page 2 Télérupteur électronique Relè a impulsi elettronico Telerruptor electrónico I. Description I. Descrizione I. Descripción 1. Bornes des contacts de sortie (3-4) 1. Morsetti dei contatti di uscita (3-4) 1. bornes de los contactos de salida (3-4) 2. Bornes des entrées de commande local (A1;A2) 2.

This manual is also suitable for:

E260-16-202ccg000981r00012ccg000972r0001