SECTION 5 SECTION 5 SECTION 5 SECTION 5 SECTION 5 TECH TIPS DIAGNOSTIC FLOW CHARTS COOKTOP NOTE: The range must be plugged in for Start at least 40 seconds before this test can begin. Does cooktop Done spark properly? Check the high voltage igniter wires for continuity and proper connections from DSI control to igniters.
Page 28
BAKE Done Check the polarity of the supply voltage. Even if no ground is connected, the DSI control will not be able to sense the presence of a flame at the igniter if the polarity is reversed. Does the Bake cycle function properly? Does the spark...
Page 29
BROIL Done Does the Broil cycle function properly? Does the spark Does the Broil Replace the gas continue after a burner establish distribution valve. flame is present? a flame and then turn off? Check the igniter for continuity. If not okay, replace the igniter.