IMPORTANT SAFETY INFORMATION. READALLINSTRUCTIONS BEFORE USING. WARNING'! For your safe_ the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury. SAFETY P RECAUTIONS Use this appliance only %r its intended Turn the mode control OR= and unplug pml)ose...
Page 3
www.GEAppliances.com WARNING! USEOFEXTENSION CORDS--115-Volt modelsonly CAUtiON: Because of potential safety hazards under certain conditions, we strongly recommend DO NOT use an extension cord with any of the against the use of an extension cord. 230/208 volt models. Howe_; ifvo/l Ill/lSt all extension cord, it is absolutely...
Aboutthe controlson theair conditioner--modelswith touchpads. Appearance may vary. Air ConditionerControls Lightsbeside the touchpadsonthe airconditioner controlpanelindicate the selectedsettings. RemoteControl Whenthe air conditioner i s turnedon,it will Controls automatically startin thesettinglast used. To cancel (CI,) tile On Timer press tile ON/ITOPo ONpad again. Turn,_ air c nditi net on and off.
Page 5
wnnN.GEAppliances.com COOLMODE Remote C ontrol become coolel; Set tile thermostat at a higJmr nm-nber and tile indoor air will become _mnel: l. Px_ss COOL pad. NOTE:ff the air conditioner is off andis then turned on 2. P*_ss LOW.MEDor HIpads to set desired fire speed.
Page 6
About the controlson the air conditionermmodels with touchpads. Auxiliary Controls- TemperatureLimiting To reach the auxiliary controls remove the fl'ont g_ille. Access them through the small rectangular opening above the control panel. Temperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling.
Page 8
Aboutthe controlsonthe air conditioner--modelswith controlknobs. • HIGH r_j_l _ FAN LOW_ _ I I I ALOW HEAT'! I I yCOOL HIGH_ll HIGH HEAT--_" COOL LOWa _ a LOW FAN_COOL HIGHm • •_ HIGH FAN w_w COOL MODECONTROL TEMP CONTROL Temp Control Mode Control HIGHCOOLand LOWCOOLl)r°'_ide The telnp control is used to inaii_tain the...
Page 9
www.GEAppliances.com Fan Switch To reach tile tim switch (es) remove tile fl'ont grille. On Heat/Cool and Heat Pump models, tile tim switch leveI_ are located in holes accessed through tile control box. Tile top switch is fin _COOL settings and tile bottom sMtch is fin"...
If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through yore" GE se_Mce outlet. Front Grille The fl'ont grille can be removed tot more 3 Pull the r,rille out fl'om the bottom and lift up...
Page 11
www.GEAppliances.com Tomaintain optimum performance, clean the filter at least every 30 days. Air Filter To remove the air filter, on uther models: Pull it down. Dirty filte_Needs cleanhTg Clogged filter Greatly reduces coolhTg heating and airflow. Turn the air conditioner off before cleaning.
• Note to Consumer - Keep these instructions GE strongly recommends the removal of the old future reference. wall case and the installation of a new GE Wall • Skill level - Installation of this appliance requires Case. If you decide to keep the existing wall case, basic mechanical skills.
Page 13
Measure GE KiT NUMBERS USE GE KIT NUMBER: FOR: DESCRIPTION: RAK56A100 GE RAB13, 14 & 15 Fits all GEwall cases 26'_/Vx 18"H x 24"D (ACLB& RCLChassis) RAK1072 Hotpoint ACXB10& 11 Adapts an older Hotpoint wall case to a "J" (ACTBChassis) model chassis.
Installation Instructions INSTALLING A J-MODEL IN AN EXISTING WALL CASE Read these instructions completely and carefully. [] REMOVE LOCKING PLATE ON [] REINSTALL LOCKING PLATE WITH FRONT LEFT SIDE TAB BEHIND WALL CASE FLANGE. TIGHTEN SCREW Locking plate [] ATTACH POWER CORD TO BASE Remove PAN WITH CLAMP screw...
Page 15
mnstaJiation mnstructions INSTALLING THROUGH THE WALL Read these instructions completely and carefully. [] PREPARE OPENING IN WALL [] SUPPORT REQUIREMENTS AIR CONDITIONER Make certain a wall receptacle available close to the hole location or make Mortar between the case and the brick all arrangements to install a receptacle.
JnstaJJation instructions WINDOW INSTALLATION--OPTIONAL FOR MODELS AJES06LSB, AJES08ASB, AJES10DSB and AJHS08ASB Read these instructions completely and carefully. inyl window gasket Sill support Case side bracket (2) x_k gasket 2 angles_ (left and Foam top right hand) window gasket Spring Case top gasket °...
Page 17
Installation Instructions []STORM WINDOW REQUIREMENTS WOOD PIECES: WIDTH: 2" A storm window frame will not allow the air conditioner to tilt towards the outside and will LENGTH: Long enough to fit inside the window keep it from draining properly. To adjust for this, frame.
mnstaJiation mnstructions WINDOW INSTALLATION--OPTIONAL (cont.) [] PREPAREWINDOW Measure 1278" from the centerline on both sides Mark the centerline of the stool. Measure from the centerline 1378" on both sides for for the sill support brackets. the panel cuts. Centerline Centerline ,stoo, 13 3/_,, .
Page 19
JnstaJJation instructions [] MEASURE, CUT AND INSTALL FILLER PANELS Gasket--_ _j¢/_ Angle Measure from the edge of the panel marks (see Prepare the Window) to the inside of Angle the window track on each side. (A and B) Sill Type C Window track _,_1 k (painted...
Page 20
Installation Instructions WINDOW INSTALLATION--OPTIONAL (cont.) [] INSTALL CASE IN WINDOW With the window closed, mark where the window sash meets the case. Peel off the backing from the bottom window gasket. Peel off the backing from the case top gasket. FB] Place the gasket on the stool and over the Hold on to the case, open the window,...
Page 21
Installation Instructions [] INSTALL WINDOW GASKET AND LOCKING BRACKET Cut the foam top window gasket to the Attach the window locking bracket with 1 type E screw. window width. Stuff the foam between the glass and the window to prevent air and insects from getting into the room.
Before youcall for service... Troubleshooting -tips:Save time and money! Review the chart below first and you may not need to call for service. Possible Causes What ToDo Airconditioner The air conditioner • Make sure tile air conditioner plug is pushed does notstart completel} imo tile outlet.
Page 23
From the date of the and all connecting tubing) which fifils due to a defect in materials or workmanship, origina!purchase During this addtional four-year limited warranty, GE will also provide, free of charge, all labor and in-home sei_'ice to replace the defective part. Service...
ConsumerSupport. 6EApp/iancesWebsite w w.CEAppliances.com H;_e a qL_esdon or m_eed _ssistaure _pphm]ce? Tv_ die (;E App]iaures Webske 24 hours a day. _rH_]] _'()_" am_y d;_v of tile veer! For greater conveniem]ce m_d {i_ster service, yol_ cm_ m_o_ dow]]]o_d ()wner's Mam_a]s, order parts, catn]ogs, or evem_ sc]]edll]e...