Spa/ethernet adapter spa to iec 61850 gateway (112 pages)
Summary of Contents for ABB Tina 7A
Page 1
Original instructions Tina 7A Adaptor unit ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety...
Page 2
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB/JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted.
Testing of the safety functions ..........................8 Troubleshooting ................................ 8 Operation ............................. 9 LED indication ................................9 Information output signal attributes........................... 9 Technical data ........................... 10 Dimensions ................................11 EC Declaration of conformity ......................12 2TLC172139M0201, rev. B www.abb.com/ljokabsafety 2013-03-02...
Introduction Scope The purpose of these instructions is to describe the adaptor unit Tina 7A and to provide the necessary information required for installation and operation. Audience This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: •...
Tina 7A is intended for use inside electrical cabinets where it can be mounted on 35 mm DIN rails and connection cables can be connected directly to screw terminal blocks on the unit. Tina 7A is also equipped with a LED for visual status information of the safety sensor and the dynamic safety circuit.
(fault exclusion, refer to EN ISO 13849- 2:2003 Annex D). The safety loops shall not be used for purposes other than intended. All loading or tampering with loops can lead to serious risk of life. 2TLC172139M0201, rev. B www.abb.com/ jokabsafety 2013-03-02...
Connection examples Caution! All cable colours according to ABB/Jokab Safety standard cables. 2TLC172139M0201, rev. B www.abb.com/ljokabsafety 2013-03-02...
(EN 62061:2005). In case of breakdown or damage to the product, contact the nearest ABB/Jokab Safety Service Office or reseller. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel.
Pluto however does release, which means that a filter (20 ms) must be implemented if this function is needed. Warning! The information output signal is not a failsafe signal and should never be used for the safety purpose(s). 2TLC172139M0201, rev. B www.abb.com/ljokabsafety 2013-03-02...
Technical data Manufacturer Address ABB AB / JOKAB SAFETY Varlabergsvägen 11 SE-434 39 Kungsbacka Sweden Article number/Ordering data Tina 7A: 2TLA020054R0700 Power supply Operating voltage 24 VDC +15 %, -25 % Total current consumption 47 mA (57 mA with max information output)
Dimensions Tina 7A NB: All measurements in millimetres. The Jokab Safety branded product with article number beginning with 2TLJ is fully compatible with the ABB branded product with article number beginning with 2TLA. 2TLC172139M0201, rev. B www.abb.com/ljokabsafety 2013-03-02...