1 Safety Precautions 1.1. General Guidelines 1. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials. 2. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the wires have been broken or disconnected, do not attempt to repair or re-wire the units.
2 Warning 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and semiconductor [chip] components.
2.2. About lead free solder (PbF) Note: Lead is listed as (Pb) in the periodic table of elements. In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder. The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu). That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
3 Service Navigation 3.1. PCB Layout Board Name Function Power Supply, Sustain Drive Non serviceable. PSS-Board should be exchanged for service. Main AV input, processing Remote receiver, Power LED, C.A.T.S. sensor Data Driver (Lower Right) Data Driver (Lower Left) Scan Drive...
4 Specifications Power Source AC 120 V, 60 Hz Power Consumption Rated power 212 W Standby power 0.3 W Display Panel Panel System Plasma Display panel Screen size 42 inch class (41.9 inches measured diagonally) W H Diagonal 36.5 inch ...
5 Service Mode 5.1. How to enter into Service Mode 5.1.1. Purpose After exchange parts, check and adjust the contents of adjustment mode. While pressing [VOLUME ( - )] button of the main unit, press [INFO] button of the remote control three times within 2 seconds 5.1.2.
Contents of adjustment mode 5.1.4. • Value is shown as a hexadecimal number. • Preset value differs depending on models. • After entering the adjustment mode, take note of the value in each item before starting adjustment. Main item Sub item Sample Data Remark WB-ADJ...
5.2. Option - Mirror Picture can be reversed left and right or up and down. 00 : Default (Normal picture is displayed) 01 : Picture is reversed left and right. 02 : Picture is reversed up and down. Hint : If the defective symptom (e.g. Vertical bar or Horizontal bar) is moved by selection of this mirror, the possible cause is in A-board.
6 Troubleshooting Guide For detailed troubleshooting information and circuit explanations, refer to the "QSM/Service Hints/Troubleshooting Information(TI)" and Seminar/Training Manual/Technical Guide(TG) documents posted on the TSN web site. For information about this model, type TC-P2013 in the model box under "Direct Search".
7 Disassembly and Assembly Instructions 7.1. Disassembly Flow Chart for the Unit This is a disassembly chart. When assembling, perform this chart conversely. 7.2. Disassembly Procedure for the Unit 7.2.1. Remove the Pedestal stand 7.2.2. Remove the AC cord clamper B 1.
Remove the Rear cover 7.2.5. Remove the PSS-Board 7.2.3. Caution: , 6 , 2 1. Remove the screws (24 To remove P.C.B. wait 1 minute after power was off for 2. Remove the M8 caps (4 discharge from electrolysis capacitors. 3.
7.2.7. Remove the Speakers 7.2.10. Remove the M8 nut metals 1. Unlock the cable clampers and the tapes to free the 1. Remove the screw (1 each) and remove the M8 nut cables. metals. 2. Disconnect the Speaker terminal. 3. Remove the screws (2 each) and remove the Speakers (L, R).
7.2.12. Remove the Cabinet assy from the 7.2.14. Remove the C1-Board Plasma panel section. 1. Disconnect the flexible cables (CB1, CB2, CB3 and CB4). 2. Disconnect the flexible cable (C10). 1. Place the Cabinet assy on a flat surface of a table 3.
8 Measurements and Adjustments 8.1. Adjustment 8.1.1. Vsus selection Caution: When Plasma panel or A-board is replaced, Vsus should be set to LOW or HIGH. Procedure 1. Go into main item [VSUS] in Service Mode. LOW or HIGH will be displayed. 2.
8.1.2. White balance adjustment Name of measuring instrument Remarks Color analyzer (Minolta CS-1000 or equivalent) Procedure Remarks 1. Enter the Service mode. 2. Receive the Analog-RF (except for no signal) or set CVBS/YUV/HDMI (no signal is available). 3. Select [WB-ADJ] by using [1] and [2] key in the remote controller. 4.
9 Block Diagram 9.1. Main Block Diagram MAIN AV INPUT,PROCESSING HDMI1-2 (HDMI2) TMDS DATA HDMI I/F USB I/F USB_1 IFD_OUT RF IN TUNER TUNER I/F V/Y/PB/PR VIDEO/ V/YPbPr/RGB/YC COMPONENT DIGITAL DIGITAL AUDIO OUT SPDIF_OUT AUDIO OUT ASDOUT0 SUB3.3V SUB3.3V STB3.3V STB3.3V POWER_LED(R) LED_R...
9.3. Block (2/4) Diagram MAIN AV INPUT,PROCESSING IC9300 PD5L VIDEO DATA PLASMA AI VIDEO DATA LVDS DATA H/V Sync Control VIDEO DATA Sub Filed Processor VIDEO DATA IC9803 P+1.2V DCDC15V P+1.2V IIC0 DATA DRIVER CONTROL +1.2V 1.2V P+3.3V DCDCEN2 D_UHZ P+3.3V SOS_DCC SUB3.3V...
10 Wiring Connection Diagram 10.1. Caution statement. Caution: Please confirm that all flexible cables are assembled correctly. Also make sure that they are locked in the connectors. Verify by giving the flexible cables a very slight pull. 10.2. Wiring (1)