Page 1
FREE JOINT MULTI AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT MH026FNCA MH050FXCA2A MH035FNCA MH080FXCA4A MH052FNCA MH026FECA MH035FECA MH052FECA NJ030MHXCA NJ035MHXCA NJ052MHXCA NJ0261HXCA NJ0351HXCA SERVICE Manual AIR CONDITIONER THE FEATURE OF PRODUCT Multi Inverter(Free Joint Multi) Series – Variable Indoor Unit Combination(Free Joint Multi) –...
Contents 1. Precautions ............................1-1 Installing the air conditioner ......................1-2 Power supply and circuit breaker ....................1-3 During operation ..........................1-4 Disposing of the unit ........................1-5 Others ..............................2. Product Specifications ......................2-1 The Feature of Product ......................... 2-2 Product Specifications ........................
Contents 9. Troubleshooting ..........................9-1 Items to be checked first ........................ 9-2 Checking and Testing operations ....................9-3 Fault Diagnosis by Symptom 9-12 ....................... 9-4 PCB Inspection 9-18 ........................... 10. Reference for Installation 10-1 ....................... 10-1 Selecting Area for Installation ....................
Do not place a cloth or other materials over it. Remove the batteries if you don’t use the remote control for a long time. (If applicable) Use the remote control within 23ft(7m) from the indoor unit. (If applicable) Samsung Electronics...
- Release the valve caps on High and Low pressure side. - Use L wrench to close the valve on the high pressure side. - Approximately 2 minutes after, close the valve on the low pressure side. - Stop operation of the air conditioner. - Disconnect the pipes. Samsung Electronics...
• Felt Structure : New felt has selected to reduce the noise coming out of the compressor. Double layered felt structure absorbs noise by two times and felt is also covering top of the compressor to reduce the noise even more. Samsung Electronics...
Page 7
2-2 Product Specifications Model MH026FNCA MH035FNCA Item INDOOR UNIT Type Wall-mounted Wall-mounted Cooling 9,000 12,000 Btu/hr Heating 10,000 13,000 Cooling 8.31 9.54 Air Volume /min Perfor- Heating 8.56 9.93 mance Cooling Noise Heating Power ø,V,Hz 1,208~230,60 1,208~230,60 Cooling Power Consumption...
Page 8
Operating Current Heating 0.30 1,065x298x128 Outer Dimension WxHxD inch 42x12x8.6 Weight Liquid OD(inch)xL(ft) ø1/4x24.6 Refrigerant Pipe Size OD(inch)xL(ft) ø1/2x24.6 Drain Hose DxL(mm) ø18x600 Cross-fan Type Resin /steel Blower Type Motor Rated Output 2ROW 16STEP Heat Exchanger Refrigerant Control Unit Samsung Electronics...
Page 9
Liquid OD(inch)xL(ft) ø1/4x24.6 ø1/4x24.6 ø1/4x24.6 Size Refrigerant Pipe OD(inch)xL(ft) ø3/8x24.6 ø3/8x24.6 ø1/2x24.6 Type Sirocco fan Sirocco fan Sirocco fan Resin/steel Resin/steel Resin/steel Blower Type Motor Rated Output 2ROW 12STEP 2ROW 12STEP 2ROW 12STEP Heat Exchanger Refrigerant Control Unit Samsung Electronics...
Page 10
ø6.35x7.5 ø6.35x7.5 Refrigerant Pipe Size mmxL(m) ø9.52x7.5 ø9.52x7.5 Drain Hose ø,mm VP20(ID20/OD25) VP20(ID20/OD25) Cross Flow Fan Cross Flow Fan Type Feedback SSR Feedback SSR Blower Type Motor Rated Output 2ROW 12STEP 2ROW 12STEP Heat Exchanger Refrigerant Control Unit Samsung Electronics...
Page 11
Liquid mmxL(m) ø6.35x7.5 ø6.35x7.5 ø6.35x7.5 Size Refrigerant Pipe mmxL(m) ø9.52x7.5 ø9.52x7.5 ø12.7x7.5 Type Turbo Fan Turbo Fan Turbo Fan Blower Type steel steel steel Motor Rated Output Heat Exchanger 2ROW 10STEP 2ROW 10STEP 2ROW 10STEP Refrigerant Control Unit Samsung Electronics...
Page 12
BLDC Permanent magnetic Motor Com- pressor Type Lubricant Oil Capacity Protection Device Type Propeller Propeller Fan Motor Blower & Size OD(mm) ø420 ø460 Blower Motor Rated Output Heat Exchanger 2ROW 28STEP 2ROW36STEP Refrigerant Control Device Charging Refrigerant(R410A) 70.55 98.77 Samsung Electronics...
2-3 Accessory and Option Specifications 2-3-1 Indoor Unit Accessories FNCA Item Descriptions Code-No. Q'TY Remark DB97-02851B (MH026FNCA/MH035FNCA) Installation Plate (Plate-Hanger) DB90-02738A (MH052FNCA) Remote Control DB93-03012P Indoor Unit User Manual DB98-29162A Installation Manual DB98-29163A The design and shape can be changed according to the model.
Pattern Sheet DB97-04095A/B (MH052FECA) Insulation-Install Outlet DB72-00143D Insulation-Install Inlet DB72-00143E Indoor Unit Drain Hose Joint DB94-00758A Rubber DB63-00237A (Grommet Hanger) Insulation-Drain Out DB62-03439H Insulation-Out DB62-03439J Insulation-Drain In DB62-03440H The design and shape can be changed according to the model. Samsung Electronics...
Product Specifications Indoor Unit Accessories(cont.) FECA(cont.) Item Descriptions Code-No. Q'TY Remark Cable-tie DB65-10088C Indoor Unit Drain Pipe Holder DB90-02064A The design and shape can be changed according to the model. 2-10 Samsung Electronics...
Page 16
Insulation cover band DB72-00109J Installation Manual DB98-33584A Indoor Unit Flexible hose DB94-01258C (Ass'y drain hose joint) Insulation drain hose DB62-04783A Rubber DB63-00237A (Grommet Hanger) Insulation hose DB72-00398B The design and shape can be changed according to the model. Samsung Electronics 2-11...
Page 17
DB62-01959D Insulation cover band DB72-00109J Insulation drain-hose DB62-04783A Indoor Unit Cable-tie DB65-00191A Ass'y drain hose DB94-01270H M4x12 tapped Screw 6002-000213 Installation manual DB98-33584A Safety net DB63-01372A The design and shape can be changed according to the model. 2-12 Samsung Electronics...
Drain Plug Out DB67-20011A Transmitter power cable DB93-05059A (Ass'y Connector Wire-DC Power) Rubber Leg DB73-20134A Outdoor Unit Installation Manual DB98-29164A Service Manual DB98-29161A Nipple Connector DB67-00789A (MH080FXCA4A) The design and shape can be changed according to the model. Samsung Electronics 2-13...
Page 19
Transmitter Power cable DB39-00378E (Wire Harness-DC Source) (MIM-B13) Transmitter communication cable DB39-00253B (Connect Wire-COM) (MIM-B13) Transmitter Case DB61-00450B (Case-Relay PCB Out) (MIM-B13) Cable-tie DB65-10088B DB98-25776A Installation Manual (MIM-B13) The design and shape can be changed according to the model. 2-14 Samsung Electronics...
Indoor unit heat exchanger temperature sensor error (open or short) Indoor fan motor malfunction Option Setting EEPROM error Option error Option Setting (option wasn t set up or option data error) Remote Control on/off Outdoor unit error Outdoor Unit Power Reset Samsung Electronics...
Page 21
: Flickering : Off If you turn off the air conditioner when the LED is flickering, the LED is also turned off. If you re-operate the air conditioner, it operates normally at first, then detect an error again. Samsung Electronics...
Page 22
: Flickering : Off If you turn off the air conditioner when the LED is flickering, the LED is also turned off. If you re-operate the air conditioner, it operates normally at first, then detect an error again. Samsung Electronics...
Page 23
Error of float switch Error of setting option switches for optional accessories EEPROM error EEPROM option error : On : Flickering : Off If you turn off the air conditioner when the LED is flickering, the LED is also turned off. Samsung Electronics...
Page 24
Outdoor unit sensor error - Condenser out sensor(Short/Open) - Self diagnosis Compressor Discharge temperature sensor error Compressor discharge sensor detached - Self diagnosis Compressor OLP sensor error (Short/Open) - Error condition : outdoor temperature under -20˚C - Error level : over 4.95V(-30˚C) under 0.5V(151˚C) Samsung Electronics...
Page 25
DC peak error (IPM Over Current) Compressor Limit Error DC link Voltage error (under 150V, over 410V) Abnormal compressor running (Compressor Rotation Error) Current sensor error DC link Voltage sensor error OTP Error Inverter micom zero-crossing error Piping(gas leak) NO GAS error(self diagnosis) Samsung Electronics...
Only blue colored 20 digits should be set Set 2 digits using Button. Press button, then will move to down. Set next 2 digits. After setting 10 digits, press button, then "OFF timer" will be displayed. Set next 2 digits. Samsung Electronics...
Page 27
If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry. If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is set up for its model. Samsung Electronics...
4-1 Indoor Unit Stop operation of the air conditioner and remove the power cord before repairing the unit. 4-1-1 MH026FNCA/MH035FNCA/MH052FNCA Parts Procedure Remark Front Grille 1) Stop the air conditioner operation and shut off the main power. 2) Open the Front Grille by pulling right and left sides of the hook.
Page 32
(Main PCB) side out. (Inclusion Power Cord) 2) Detach the outdoor unit connection wirefrom the Terminal Block. 3) Loosen 4 fixing screws of Ass’y Control-In. (Use +Screw Driver.) Tray Drain 1) Pull Tray Drain out from the Back Body. Samsung Electronics...
Page 33
5) Lifting the Heat Exchanger up a little to push the up side for separation from the indoor unit. 1) Loosen the fixing screw. Fan Motor 2) Detach the Fan Motor from the Fan. & 3) Detach the Fan From the left Holder Cross Fan Bearing. Samsung Electronics...
Page 34
(Use +Screw Driver.) Blower 2) Disassemble 2 Cover Blower Uppers. - After unscrewing 2 screws (Use +Screw Driver.) - Disassemble the Cover Blower Upper with pushing its hook. 3) Disassemble the Cover Control. - Unscrew 2 screws (Use +Screw Driver.) Samsung Electronics...
Page 35
- Unscrew a screw (Use +Screw Driver.) 6) Disassemble the band Motor for fixing the Motor. - Unscrew 2 screws (Use +Screw Driver.) 7) After disassembling the Motor and Blower for the set, disassemble the Blower by use of 0.12inch(3mm) wrench. Samsung Electronics...
Page 36
1) Disassemble the Cabinet Top Evap. - Unscrew 11 screws 2) Disassemble the Bracket Outlet Sub that fixes the Drain Pan equipped on the front of the set. - Unscrew 6 screws 3) Disassemble the Drain Cushion from the set. Samsung Electronics...
Page 37
EEV wire that connected to the inside of PCB. 3) Disassemble the Support Evap. LF that fixes the Evaporator. - Unscrew 2 screws (Use +Screw Driver.) 4) Disassemble the Support Evap RH. - Unscrew 2 screws (Use +Screw Driver.) Samsung Electronics...
Page 38
Case. 4) In case of disassembling the Case Control, disassemble the Case Control from the set after unscrewing the screw connected to the direction of Blower. - Disassemble if after disassembling the Cabinet Top Motor 1-1). Samsung Electronics...
Page 39
5) In case of disassembling the Trans Power, unscrew the screw fixing on the Case. Disassemble if after disassembling the case PCB 4-4). Bracket Outlet 1) Disassemble the Bracket Outlet assembled on the Cabinet. - Unscrew 10 screws (Use +Screw Driver.) 4-10 Samsung Electronics...
Page 40
Disassembly and Reassembly 4-1-3 MH052FECA Parts Procedure Remark 1) Pull out the Filter as picture 1 or picture 2. Filter 2) If it is necessary, after disassembling 8 indicating screws, detach the Bracket Filter. Samsung Electronics 4-11...
Page 41
Ass’y Cabinet-Top Motor. & Motor (Use +Screw Driver.) 2) After disassembling 3 indicating screws, detach Ass’y Case Blower Upper. (Use +Screw Driver.) _ Press the pothook of the Case Blower and detach Ass’y Case Blower Upper. 4-12 Samsung Electronics...
Page 42
4) Detach the Motor Wire Connected to PCB and Capacitor. 5) After disassembling the indicating screws, detach the wire connected to the Partition. (Use +Screw Driver.) 6) After disassembling 2 indicating screws, detach the Ass’y Band Motor. (Use +Screw Driver.) Samsung Electronics 4-13...
Page 43
Motor by 3mm inner hexagon spanner. Drain Pan 1) After disassembling 15 indicating screws, detach Ass’y Cabinet-Top Evap. (Use +Screw Driver.) 2) After disassembling 6 indicating screws, detach the Bracket Outlet. 3) Detach the Drain Pan. 4-14 Samsung Electronics...
Page 44
2) Detach the Sensor from the Control Box.(including 2 Sensors) 3) After disassembling 2 indicating screws, detach Ass'y Support Evap LF. (Use +Screw Driver.) 4) After disassembling 2 indicating screws, detach Ass'y Support Evap RH. (Use +Screw Driver.) Samsung Electronics 4-15...
Page 45
3) If only the disassembly of Capacitor is required, detach it from the set. 4) If only the disassembly of Case Control is required, detach it from the set after disassembling 2 indicating screws. (Use +Screw Driver.) 4-16 Samsung Electronics...
Page 46
Disassembly and Reassembly Parts Procedure Remark 5) Detach the Transformer after disassembling 2 indicating screws. Work is possible after disassembling the Case PCB. 1) After disassembling 16 indicating screws, Ass'y Bracket detach Ass'y Bracket Outlet. Outlet (Use +Screw Driver.) Samsung Electronics 4-17...
Page 47
5) Loosen 2 fixing screws, 5 bolts and detach the Front Cabinet. (Use +Screw Driver.) 6) Loosen 2 fixing screws and pull up the Control Box. (Use +Screw Driver.) 7) Loosen 9 fixing screws and detach the Cabinet Side. (Use +Screw Driver.) 4-18 Samsung Electronics...
Page 48
1) Loosen the fixing nut and detach the Fan. (Use +Screw Driver.) & Motor 2) Loosen 4 fixing bolts and detach the Motor. (Use +Screw Driver.) 3) Loosen 4 fixing bolts and detach the Bracket Motor. (Use +Screw Driver.) Samsung Electronics 4-19...
Page 49
2) Disassemble the Inlet and Outlet Pipe by & welding. Compressor 3) Loosen the fixing screws of the Heat Exchanger. (Use +Screw Driver.) 4) Detach the Heat Exchanger. 5) Loosen 3 nuts of the Compressor. (Use Monkey Spanner.) 6) Detach the Compressor. 4-20 Samsung Electronics...
Page 50
3) Loosen 2 fixing screws of the Ass'y Control Out. (Use +Screw Driver.) 4) Loosen 6 fixing screws and detach the Cabinet Upper. (Use +Screw Driver.) 5) Loosen 2 fixing screws, 7 bolts and detach the Cabinet Front. (Use +Screw Driver.) Samsung Electronics 4-21...
Page 51
Disassembly and Reassembly Parts Procedure Remark 6) Loosen 2 fixing screw and pull up the Control Box. (Use +Screw Driver.) 7) Pull the felt and detach it. 8) Detach the Terminal Cover and detach the comp lead wire. 4-22 Samsung Electronics...
Page 52
2) Disassemble the Inlet and Outlet Pipe by Compressor welding. 3) Loosen the fixing screw of the Heat Exchanger. (Use +Screw Driver.) 4) Detach the Heat Exchanger. 5) Loosen 3 nuts of the Compressor. (Use Monkey Spanner.) 6) Detach the Compressor. Samsung Electronics 4-23...
5. Exploded Views and Parts List 5-1 Indoor Unit 5-1-1 MH026FNCA/MH035FNCA Samsung Electronics...
Page 55
Exploded Views and Parts List Parts List Q'TY Code No. Description Specification SA/ SNA MH026FNCA MH035FNCA DB94-00454J ASS'Y BACK BODY ASS'Y DB94-00454H ASS'Y BACK BODY ASS'Y DB61-01632D BACK BODY HIPS DB69-00834A CUSHION BACK BODY DB96-03149A ASS'Y SUPPORT EVAP RH HIPS...
Page 56
Exploded Views and Parts List 5-1-2 MH052FNCA Samsung Electronics...
7. Schematic Diagram 7-1 Indoor Unit FNCA This Document can not be used without Samsung's authorization. Samsung Electronics...
Page 81
Schematic Diagram FECA This Document can not be used without Samsung's authorization. Samsung Electronics...
Page 82
Schematic Diagram 1HXCA This Document can not be used without Samsung's authorization. Samsung Electronics...
Page 83
Schematic Diagram MHXCA This Document can not be used without Samsung's authorization. Samsung Electronics...
Page 84
7-2 Outdoor Unit 7-2-1 MH050FXCA2A/MH080FXCA4A Temperature sensor & EEV SMPS Inverter This Document can not be used without Samsung's authorization. Samsung Electronics...
8. PCB Diagram 8-1 MAIN PCB(Indoor Unit) FNCA The red number connecter is not used. & Power Temperature Sensor Motor RPM Feedback Auto Grill Remocon Module HVPS(High voltage Generator) Humidity Sensor BLADE-H Step Motor Anions Display Indoor Fan Motor Samsung Electronics...
Page 86
Heater Temperature Option Switch Wired Remote Controller Power(12V) Fan (Tap Control) Control Signal Ventilator & Drain Pump “ Display Hot Coil ‘ Operating Check Signal Fan (SSR) HALL IC Trans In Download Main Power COM 1 Trans out Samsung Electronics...
Page 87
CN41-Temp. sensor CN51-FLOAT S/W CN61, CN62-Slide Panel CN83- External Control #1:ROOM Temp. Sensor #1:GND #1:On/off Contact point input #1,#6:DC12V #2:GND #2:Float S/W #2~#5:Motor Control #2:GND #3:EVA IN Temp. sensor #7~#10:Not used #4:GND CN42-Temp. sensor #1:EVA OUT Temp. Sensor #2:GND Samsung Electronics...
Page 88
PCB Diagram 1HXCA (cont.) - Panel CN01 : Connect the Main PBA of the Indoor Unit #1~#5:Control Display LED #6:Not used connection #7:Receive signals from wireless remote controller Connector #8:GND #9:VCC (DC5V) Samsung Electronics...
Page 89
DC12V Out(Wired Remocon Power) : YW396-02V(WHT) Panel Louver(Stepping Motor) : SMW250-10(WHT) Micom Program Download : SMW200-10(BLK) “ External Control Out(Error, Compressor State) : SMW250-04(RED) Display PCB : SMW200-9(WHT) ‘ External Control In(On/Off Control Signal) : SMW250-02(RED) SSR Fan Control : SMW250-03(WHT) Samsung Electronics...
8-3 MAIN PCB(Outdoor Unit) MH050FXCA2A/MH080FXCA4A Power N COND/OLP Temperature Sensor & Power L DIS/OUT Temperature Sensor BLDC FAN EEV Connector AC FAN Comp. Connector Wire Communication 485 Reactor Connector Wire Samsung Electronics...
The compressor stops intermittently in a The compressor stops intermittently or the fan speed of the COOL mode or DRY mode, and fan speed of the indoor unit decreases to prevent inside/outside air frozen indoor unit decreases. depending on the inside/outside air temperature. Samsung Electronics...
First current EEV2 current step Target Discharge temperature EEV3 current step Total capacity of the indoor units Fan RPM (H:high,L:low,Blank:off ) Safety control • The EEV 2 and EEV 3 of MH050FXCA2A model is always displayed as blank. Samsung Electronics...
Page 94
Button [K1] 1 times DIS 01 DIS 02 Display [DIS 01 ] is flickering on the setting time. Outdoor Temperature 32˚F or more less than 32˚F Time duration (Cool mode) (Heat mode) 5min~10min 20min~50min Samsung Electronics...
Page 95
- On this mode the controller will ignore the manual address number set on the rotary switch on the indoor PCB. - To confirm the indoor address number assigned by this mode, use "TEST MODE" and the address number will be displayed on the LED display on the indoor unit. Samsung Electronics...
Page 96
02--communication with indoor unit C; 03--communication with indoor unit D; In case of Manual address mode,you can do pipe check operation for check whether you connect the pipes correctly or not. But you need set indoor address switch yourselves. Samsung Electronics...
Page 97
Troubleshooting Switch Setting and Testing Operation (cont.) TO SET ADDRESSING MANUALLY BY ROTARY TYPE PICTURE MODEL SWITCH “SW02 ” MH026FNCA MH035FNCA MH052FNCA MH026FECA SLIM DUCT MH035FECA MH052FECA SW02 SLIM 1 WAY NJ0261HXCA CASSETTE NJ0351HXCA NJ030MHXCA MINI 4 WAY NJ035MHXCA CASSETTE...
Page 98
Cooling mode (indoor unit check) → Inlet air temp.-Outlet air temp : From 10°K to 12°K (indicative delta T) Heating mode (indoor unit check) → Outlet air temp.-Inlet air temp : From 11°K to 14°K (indicative delta T) In heating mode,the indoor fan motor can remain off to avoid cold air blown into conditioned space. Samsung Electronics...
Page 99
Indoor unit heat exchanger in temperature sensor error (open/short) E237 E251 Condenser temperature sensor error (open/short) Compressor Discharge temperature sensor error (open/short) E251 Compressor OLP sensor error (open/short) E320 Please, The System turn off and replace sensor which is related. Guidance Samsung Electronics...
Page 100
Replace outdoor unit’s ass’y control or indoorr unit’s Step 2 EEV Coil ass’y control. Basically, This error caused by communication between indoor units and outdoor unit. Guidance First of all, check the all coommunication connection and PCB’s status. Samsung Electronics...
Page 101
This is caused by protection mode behavior. Analysis This is indoor Evaporator Freezing protection mode. Step 1 Please, check indoor unit, whether inlet or outlet grill is closed. Step 2 Please, check indoor unit, whether indoor fan is working. 9-10 Samsung Electronics...
Page 102
Error code. Check point Remarks These Error codes only apply with Try-run mode, in case of system have some defect as result of try-run operation. Analysis Refer to self-detection algorithm (Check Error Code meaning and check it out) Samsung Electronics 9-11...
2 digit alternatively. Any Error code on LED display? Wait for 5 minutes to check error code Consult error code table because some error judgement needs long time Check Major parts(See 12-5) Consult error code(Next Page) 9-12 Samsung Electronics...
Page 104
? Error related to outdoor controller except Consult LED pattern on wiring diagram on temperature sensor and communication outdoor controller between indoor unit and outdoor unit ? See Error Code Table and Check “Main checking point” Samsung Electronics 9-13...
Page 105
After power off this error will display until Blink DC LINK capacitor discharged.(Max 20sec.) Blink Option error (EEPROM error) Abnormal condition Blink Comp. peak current (Over Current) Blink Comp. starting error Comp. rotation error Blink DC-Link voltage error Blink Comp. V Limit Error 9-14 Samsung Electronics...
Page 106
Press K4 key on the outdoor display PCB for several times to change the display to sensor temperature value. Left 1 digit of the LED is data index and Right 3 digits are the value Index Value Remark Estimated Primary current value from The unit is 0.1A Compressor current Samsung Electronics 9-15...
Page 107
Press K4 key on the outdoor display PCB for several time to change the display to sensor temperature value. Left 1 digit of the LED is data index and Right 2 digits are the value. Index Value Remark Discharge sensor temperature OLP sensor temperature The unit is degree C Condenser sensor temperature Outdoor sensor temperature 9-16 Samsung Electronics...
Page 108
Left 1 digit of the LED is data index and Right 3 digits is the value. Index Value Remark EEV-A step EEV-B step The step value range is between Zero and 480. EEV-C step EEV-D step 9-3-7 Pipe matching See 9-2 "Checking and Testing operations". Samsung Electronics 9-17...
9-4-2 Procedure 12-4-2 The parts should be replaced in the following procedure. Check for any faulty part. Detach the faulty part. Replace it with a new part. Check the operation of the new part. The repair is completed. 9-18 Samsung Electronics...
• It is harmful to the air conditioner if it is used in the following environments: greasy areas (including areas near machines), salty areas such as coast areas, areas where sulfuric gas is present such as hot spring areas. Contact your dealer for advice. Samsung Electronics 10-1...
Page 111
2. Make sure that you put the remote control unit in an area not exposed to direct sunlight, and where there is no source of heat. 3. Make sure that you use the remote control unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixtures and other electrical appliances (at least 3.3ft). 10-2 Samsung Electronics...
183kgf•cm with a torque wrench. Service port 7. Check for gas leakage. • At this time, especially check for gas leakage from the 3 way valve’s stem nuts, and from the service port cap. Samsung Electronics 10-3...
Page 113
6 Mount the valve stem nuts and the service port cap to the valve,and tighten them at the torque of 183kgf•cm with a torque wrench. 7 Check for gas leakage. - At this time,especially check for gas leakage from the 3-way valve ’s stem nuts,and from the service port cap. 10-4 Samsung Electronics...
7) Stop operation of the air conditioner. 8) Close the 3 way valve, disconnect the pressure gauge, and open the 3 way valve again. 9) Close the cap of each valve. Samsung Electronics 10-5...
Page 115
7) Stop operation of the air conditioner. 8) Close the 5/8" service valve, disconnect the pressure gauge, and open the 5/8" service valve again. 9) Close the cap of each valve. 10-6 Samsung Electronics...
6. Make sure you do not bend the connection pipes in the middle and store together with the cables. • 7. Move the indoor and outdoor units to a new location. • 8. Remove the mounting plate for the indoor unit and move it to a new location. Samsung Electronics 10-9...
Page 119
6. Make sure you do not bend the connection pipes in the middle and store together with the cables. • 7. Move the indoor and outdoor units to a new location. • 8. Remove the mounting plate for the indoor unit and move it to a new location. 10-10 Samsung Electronics...
200~220V, 50Hz Free Inverter Version 220~240V, 50Hz Redd Digital Scroll _,12.. Indoor 127V, 50Hz _,A,B.. Outdoor Indoor/Outdoor Type Refrigerant 1 way Slim 1 way R407C Mini 4 way R410A Silhouette Duct Slim Vivave Moderato Console CONV Outdoor Samsung Electronics 11-1...
Page 121
FREE JOINT MULTI FOR EUROPE Buyer code Product Type Capa Serial Version Indoor Capacity Multi *K BTU Basic - CAP Indoor(K BTU) MR(02R~) Outdoor Mode Refrigerant R410A Inverter Semi Product Indoor Outdoor R407C Indoor Type Vivave Moderato 11-2 Samsung Electronics...
Page 122
380V, 60Hz, CONV R410A/PRM Console 3phasea Capa R410A/Flagship 460V, 60Hz, FAC & Large Capacity KW/BTU'Liter 3phasea Vivace Version Neo-Forte (EEV) Export Neo-Forte Solar (Water) Tank Crystal High efficiency EER mode indoor unit Hydro Unit HYDRO Water tank Samsung Electronics 11-3...
Heat exchanger; A device, used to transfer heat from a fluid on one side of a barrier to a fluid ASS’Y EVAP/ASS’Y COND on the other side without bringing the fluids into direct contact. (Full name : assemble evaporator / assemble condenser) 11-6 Samsung Electronics...
It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer. Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump problems.
Page 127
Set up a sun blind over the outdoor unit and clear the neighboring obstacles from the outdoor unit to provide good ventilation. When it goes off frequently during a heat wave, it would prevent the turn-off and increase the cooling capacity cleaning the outdoor unit or spraying some water to the heat exchanger. 11-8 Samsung Electronics...
Page 128
There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process.
But generally the value of fresh indoor temperature is that below 0.2(m/s) of indoor air circulation, the temperature is 21~28˚C when the wall temperature is the same as the indoor's and relative humidity is 30~31% in summer, the winter temperature is 20~24˚C and relative humidity is 30~60% in winter. 11-10 Samsung Electronics...