Table of contents Introduction ..................7 Safety instructions.................. 7 Installation requirements ................. 8 The fire ..................8 False Chimney breast ................ 8 Requirements flue system and outlets............ 8 terminals ..................9 Preparation and Installation instructions ............9 Gas connection ................9 Electric connection ................
Page 7
11.1 Points of particular interest: .............. 16 11.2 Sample computations............... 17 Table ..................... 18 Technical data .................. 19 Dimentions of the appliance left-hand side ..........20 Dimensions of the appliance left-hand side with decoration plate ....21 Dimentions of the appliance right-hand side ..........22 Dimensions of the appliance right-hand side with decoration plate....
1 Introduction The appliance can only be installed by a competent person in accordance with the Gas Safety. We urgently advise you to read this installation manual properly. This appliance complies with the guidelines for European gas appliances (Gas Appliances Directive) and bears the CE mark.
The false chimney breast and its construction may not rest on the appliance Requirements flue system and outlets You should always make use of the materials prescribed by Faber International Ltd. Only by using these materials can Faber International Ltd. guarantee a proper functioning.
terminals The flue outlet can end on an external wall or a roof . Check whether the outlet desired by you complies with local requirements concerning good function and ventilation systems . For a proper functioning the terminal should be at least 0.5 m. away from: ...
Placing the appliance Take the installation requirements into account (see chapter 3 ) 4.4.1 Standing on the floor Place the appliance into the proper position and if necessary, adjust the height with the adjustable legs. Adjusting the height and leveling the hearth with a spirit level.(see fig. 1.4) ...
False Chimney breast Construct the false chimney breast from non- combustible material in combination with metal profiles or of brickwork / aerated concrete bricks. Take the grills and the service panel (see fig. 1.1 an1.2 )into account. Place a protective shield made of non- combustible material above the grills (see fig 1.1 A) ...
Remove the front glass first. Place the suction discs onto the glass Remove the sealing cord from the groove Slide the glass upwards now, so that the bottom edge is released from the groove. Now gradually move the bottom edge of the glass forwards slantwise and lower the glass into the opening between the build-in frame and the appliance.
double layer. The surface of the pebbles may be very slightly higher than the burner tube ( see fig. 3.3) Place the glass and check the flame picture into the appliance 7 Checking the installation. Checking the ignition of the pilot burner, main burner. Start the pilot and main burner according to the instructions in the user’s manual.
* Close the pressure gauge nipples and check these for gas leaks. Checking the flame picture. Allow the applaince to burn for at least 20 minutes at full and then check the flame picture for: 1. Distribution of the flames 2.
9 Annual maintenance Service and cleaning: Check and clean if necessary after checking: o The pilot light o The burner o The combustion chamber o The glass o The logs for possible fractures o The outlet Replace: o If necessary the chips/embers. Cleaning the glass Most of the deposits can be removed with a dry cloth.
11 Calculation of flue system The possibilities for the lengths of flue pipes and the possible restrictors have been recorded in a table (see chapter 12 ) This table works with a vertical and a horizontal length. To define the vertical length all lengths of flue pipes in a vertical direction should be added up.
11.2 Sample computations Sample calculation 1 Count the horizontal lengths Flue pipe lengths C+E = 1 + 1 Bend D = 1 x 2 m Total Count the vertical lengths Flue pipe length A Roof terminal G Total Sample calculation 2 Count the horizontal lengths Flue pipe lengths J + L = 0,5 + 0,5 1 m Bends...
12 Table Find the correct vertical and horizontal lengths in the table. In case of an “x”, or if the values are outside the table, the combination is not permitted. The value found indicates the width of the restrictor to be placed ("0" means no restrictor should be placed).
13 Technical data Gascat. 2H3+ 2H3+ 2H3+ Type appliance C11 C31 C11 C31 C11 C31 Reference gas 12,2 Input Nett Efficiency class NOx class mbar inlet-pressure 1278 Gas rate at 15ºC and 1013 mbar gr/h Gas rate at 15ºC and 1013 mbar mbar 29,6 Burner pressure at full mark...