Contents Important Safeguards............................2 Introduction..............................3 Features Of Your New Portable Air-Conditioner ..................3 Energy Saving Tips ............................3 Specifications ..............................4 Parts List ................................5 Accessories..............................5 Installation................................ 6 Control Panel ..............................8 Operating Instructions ............................ 8 Aqua Chill Technology..........................
Introduction Thank you for choosing an omega altise portable air conditioner. This manual contains information, regulations and warnings which are of fundamental importance if the appliance is to be installed correctly and the highest performance, in the safest possible conditions, is to be obtained. We suggest that you read the manual carefully before installing or starting up the unit.
Parts List Front 1. Control panel 2. Air outlet grille 3. Carrying handle 4. Castors (4) Back 5. Removable air filter 6. Air inlet grille 7. Power cord storage and water injection port 8. Exhaust outlet / adapter 9.
Installation • Before you use this unit please ensure it has been kept upright for at least 24 hours. • The unit should be installed in a flat dry place. • Leave at least 50cm space around the unit (Fig. 1).
Mounting of the flexible exhaust hose • The bend of the exhaust pipe is very important. • Take care to prevent any sharp bow or bend in the exhaust. • The exhaust air must flow freely otherwise the performance of the portable air conditioner may be adversely affected or the unit may malfunction.
Page 9
Fan Mode The Fan or ventilation mode “moves” the air allowing for the recycling of air much like a general fan. • Press MODE button to choose FAN mode. • Press SPEED button to select the fan speed, either low or high.
Page 10
Timer – Off • When the unit is operating press the TIMER button to set timer-off. • Press UP or DOWN buttons to adjust the time from 1hr to 24hrs. • Time will vary 1hr accordingly for each press of either the UP or DOWN buttons.
Aqua Chill Technology When operating in Cool Mode this unit uses a self-evaporative system that extracts water from humid environments and collects it in an internal water tank. Once sufficient water is collected it is recycled over the condenser, assisting to cool the condenser and internal refrigerant gas faster than only air.
Water Drainage When the water tank is full, the WATER FULL indicator will illuminate and the compressor will stop working. A buzzer will sound Pressing any button will stop the buzzer. You will need to empty the water tank before the unit will work again.
Maintenance Cleaning Turn off the unit and pull the plug out of the socket before cleaning. 1. Clean the surface • Clean the surface of the unit with a duster or a damp soft cloth. • Do not use chemical solvent like benzene, alcohol, gasoline and etc, or the surface may be damaged.
WARNING! Do not attempt to repair the unit yourself. Doing so could void the warranty and cause damage or personal injury. Omega Altise products are distributed in Australia by MEA, (A Division of Hagemeyer Brands Australia Pty Ltd) ABN 28 001 375 686, Locked Bag 4013, Kingsgrove NSW 2208 Phone: 1300 739 033 Fax: 1800 838 899 Email: customerservice@meaappliances.com.au Web: meaappliances.com.au...