Do not operate with other components not approved by the ESS systems. (Connecting other products in parallel to Samsung SDI's products may result in abnormal operation.) The internet connection is required to use all functions of the ESS system.
Table of Contents Table of Contents Table of Contents ......................i Table of Tables ......................iii Table of Figures ......................iv 1. Information in this Manual ..................1 About this Manual ............................ 1 Target Group .............................. 1 Additional Information ........................... 1 Symbols Used ............................
Page 3
Table of Contents 5.3.1 Service Terms..........................27 5.3.2 Membership ..........................27 5.3.3 Membership Withdrawal ....................... 29 5.3.4 Log-In............................29 5.3.5 Password Initialization ......................30 5.3.6 Types of Service Offered ......................30 5.3.7 Mobile Service .......................... 33 6. Maintenance for Problem Solving ..............34 Fan Exchange ............................
1.1 About this Manual ’ This is the user s manual for the Samsung 3.6 kWh All in One. This user manual is specially ’ designed to detail the device s functions and features. Please read this manual before using the device to ensure safe and proper use.
Page 9
Information in this Manual Symbols Meaning Beware dangerous voltage. The inverter operates at high voltage. All works related to the inverter can only be performed by an electrical technician. Beware of hot surface. The inverter can become hot during operation. Avoid contact during operation.
Page 10
Information in this Manual Number Symbol Description Three-phase alternating current with neutral conductor Earth terminal Protective conductor terminal Frame or chassis terminal Refer to the operating instructions On (supply) Off (supply) Equipment protected throughout by double insulation or reinforced insulation Caution: Risk of Electric Shock Caution: Hot Surface Caution: Risk of Danger...
Information in this Manual Number Symbol Description Output terminal or rating Bidirectional terminal rating Caution: Risk of Electric Shock and Energy Storage Timed Discharge Caution: Risk of Hearing Damage and Wear Hearing Protection Wear hearing protection [Table 1-1: Symbol Description] Australia (Eng.) 05/2015.
Li-Ion Battery charge and discharge. The basic operations are as follows. Samsung 3.6 kWh All In One uses solar energy power connected to the input/output terminal installed on the side of the device to charge the Li-Ion Battery installed inside, and...
Page 13
Safety Identifying the Product Attached on the enclosure of this product is the Type Label where the identity of this product is described. For safe usage, make sure that the following product information is indicated on the Type Label. ■...
[Figure 2-2: Name Plate] 2.1.1 Installation Application Suitable for Safety This device, Samsung RES 3.6 kWh All in One, is designed to be suitable for household purposes. The PV Input terminal is composed of two Strings. One PV String input must install 3.3 kW or less PV panel capacity, and the maximum input voltage of the PV String must be...
To connect 3.6 kWh All In One with the Public Grid, make sure to install the watt-hour meter recommended by Samsung SDI (refer to the installation manual) and to install the distribution box between 3.6 kWh All In One and the Grid watt-hour meter. Before installing the distribution box, select a suitable location complying with the IP21 and use the equipment recommended by the installation company.
Safety 2.1.2 Technical Specifications PV Data (DC) Max. input total power 6.6 kWp Max. input power per string 3.3 kWp Max. input voltage 550 V Min. input voltage/Initial input voltage 125 V/150 V MPPT voltage range 125 V~500 V Max. input current per string 15 A Max.
Safety and AC power > 50% of the rated power) Efficiency (PV to Grid) European efficiency 95 % Max. efficiency 95.5 % Protective Device DC disconnection device for PV Ground-fault monitoring/grid monitoring Yes/Yes General Data Dimensions (W/H/D) 1000/680/267 mm Weight 95 kg Protective class (I, II, III) Class I...
Safety 2.2 Safety Guidelines DANGER High voltages in power conditioning circuits. Lethal hazard of electric shock or serious burns. The following work on the inverter must be carried out by qualified personnel only. Electrical insulation Repairs Modification Except when under supervision by qualified personnel, children or people lacking physical, mental, or intellectual capabilities should not work on this system.
One is damaged, do not touch it. Please immediately contact your installer or Samsung SDI for arrange for a repair. 2. Please contact your installer or Samsung SDI if a significant event message is shown on the LCD screen or if the All In One system reports an event.
The basic operating modes consist of PV generation mode, PV generation + charge/discharge mode. The operation mode of this product is automatically determined by the EMS algorithm. [Figure 3-1: Part View of Samsung All in One] Description Li-Ion battery INVERTER (PV inverter and battery charger / discharger)
Operating Modes 4. Operating Modes As shown in the [Figure 4-1], the status of this system is displayed in real-time on the indication screen (LCD screen). This status indication screen extends to 4-digit numbers. The icons are defined for each state and the details are described in the ensuing subsections. [Figure 4-1: Front status indication screen] 4.1 Descriptions of Operation Mode This system is composed of six modes: PV Auto, PV Only, Battery discharge, Standby,...
Operating Modes [Figure 4-6: PV generation, Buy shortage amount] 4.1.3 Battery-Discharge Mode This mode permits of no solar energy generation. Battery discharge is only available on this mode. Based on the EMS decision, the battery discharge power can be sent maximum 2kW or less only to the LOAD.
Operating Modes [Figure 4-9: Indication screen on Standby Mode] 4.1.5 Forced-Charge Mode (Maintenance mode) (1) In this mode, solar energy generation is not used, but the power continuously flows from the electric power system to the battery. [Figure 4-10: Indication screen on Forced charged Mode] 4.1.6 Stand-Alone Mode When the All In One is disconnected from the energy meter, or the power conversion system is disconnected from the energy management system (EMS), the All In One system enters...
Operating Modes 4.1.7 Event Check Mode This mode stops solar energy generation and put it in standby mode as an event occurs. [Figure 4-12: Event occurrence, Grid RMS over current protection] [Figure 4-13: Event occurrence, DC link over voltage protection] [Figure 4-14: Event occurrence, PV string1 reverse connection protection] [Figure 4-15: Event occurrence, PV string2 reverse connection protection] Australia (Eng.) 05/2015.
Operating Modes [Figure 4-16: Event occurrence, PV string1 over voltage protection] [Figure 4-17: Event occurrence, PV string1 over current protection] [Figure 4-18: Event occurrence, PV string2 over voltage protection] [Figure 4-19: Event occurrence, PV string2 over current protection] [Figure 4-20: Event occurrence, Battery over voltage protection] Australia (Eng.) 05/2015.
Operating Modes [Figure 4-21: Event occurrence, Battery over current protection] [Figure 4-22: Event occurrence, On sequence Inverter DC link event] [Figure 4-23: Event occurrence, On sequence Battery V/I event] [Figure 4-24: Event occurrence, Normal Inverter DC link event] [Figure 4-25: Event occurrence, Normal Battery V/I & BDC DC link event] Australia (Eng.) 05/2015.
Operating Modes [Figure 4-26: Event occurrence, On sequence Inverter DC link event] [Figure 4-27: Event occurrence, Normal Inverter DC link & PV I event] [Figure 4-28: Event occurrence, Temperature protection] [Figure 4-29: Event occurrence, Over Current TZ Fault] [Figure 4-30: Events occurrence, temperature sensor connection error] Australia (Eng.) 05/2015.
Operating Modes 4.2 Starting the System After completing the installation, turn on the AC circuit breaker and the DC disconnect switch installed in the distribution box (distribution board). (see the Section 5.7 in the installation guide) Check the system check message on the front LCD screen. [Figure 4-36: Initial indication screen on power on] After finishing the system check, check the system, the PV, and the battery status.
Communication 5. Communication 5.1 Overview When the Internet connection is properly completed, you can monitor the system operation status on the computer. 5.2 Components and LAN Connection 5.2.1 Essential Components Internet service line Wired Router RJ45 LAN connection cable ...
Communication Check Internet connection status You can use the information on the LED lighting status to check the Internet connection status. Function per LED Upper LED: Turns on automatically when connected to the Internet line (Connection). Lower LED: Blinks when there is data. (Rx, Tx) LED status on normal connection ...
Communication [Figure 5-2: Connecting to the website] Press the "New Account" button to register as a new member. First time users of the service must sign up for membership. Enter the required information and additional information to sign up for membership. Lastly, agree to the service subscription terms and conditions, and then press the "Submit"...
Communication 5.3.3 Membership Withdrawal For a customer who does not want to use this service, membership withdrawal is available through the personal information modification menu on the homepage. 5.3.4 Log-In Log in to the homepage through the ID and the password generated through membership registration.
Communication 5.3.5 Password Initialization A customer who forgets the password during use can initialize the password by using the “ password initialization menu on the homepage. On the log-in page, select the Forgot your ” id or password? menu, and when the customer confirms the ID and the e-mail address created during membership registration, the initialized password is sent to the registered e- mail address.
Communication [Figure 5-6: Monitoring page] 5.3.6.2 Consumption Report The household power consumption information collected during energy meter linkage is provided. In particular, such information on as the household type, the size, and the number of family residents is collected according to the customer's approval. You can use these data to identify various types of statistics and comparative analysis data.
Communication 5.3.6.3 ESS Report On the ESS Report page, you can check various types of data generated through ESS operation. You can also use the ESS Report to check the amount of energy charged or discharged and other data comparisons with the solar energy production amount or the power sales amount.
Communication 5.3.7 Mobile Service Customers who use Android or I-Phone can use a smart phone to easily check the product status anytime, anywhere. To use the mobile service, the customer must first register the membership through the webpage and use the ID and the password to log-in. [Figure 5-9: Mobile service page] Australia (Eng.) 05/2015.
Maintenance for Problem Solving 6. Maintenance for Problem Solving WARNING Do not disassemble the parts in operation for cleaning purposes. High voltage can cause lethal damage to the human body. Please make sure that the AC and DC switch relay in the distribution box is disconnected before disassembling the system.
Maintenance for Problem Solving Exchange the fan. Once the fan has been exchanged, follow the stages from 1 to 4 in reverse order to install ∙ a new fan. Use 1.3~1.6N m torque to tighten and fix the screw. Check the fan state. Once a new fan has been installed, perform a test operation to check whether there is a fan event message.
Maintenance for Problem Solving Use a torque screwdriver of 1.3-1.6 Nm and tighten the screws to attach the side cover. 6.3 Checking the Event Logs You can check the event messages on the website (https://myess.samsungsdi.com) and identify various causes of the event message described in the following chapter (Chapter 7) to perform a correct measure.
Message Description 7. Message Description 7.1 Messages in Normal Operation Status message Description Remark Operation mode under progress NOP State Warning and fault state When this icon is displayed, check the event list. Normal communication state Indicating PV, BATT, GRID value Indicating the integrating power value of each mode Indicating the frequency under...
Message Description 7.2 General Events The general events contain warnings and protection. The warning level events does not stop the generating process. A displayed warning message automatically disappears as soon as the issue is resolved. When protection level events occur, the product stop the generating process. The process may automatically resume as long as the issue is resolved.
Message Description message, with no special change in the sequence. The warning message disappears on reversion to the normal state. E006 BATT CONNECTION When the battery connection is WARNING abnormal. This is the connection warning message, with no special change in the sequence.
Page 47
Message Description Type Code Description Measures CONNECTION process because a significant PROTECTION PROTECTION event has occurred. Wait until the event message disappears. After the event message is removed, it automatically returns to normal. If it is not removed until the time limit is reached, it is converted to a significant event.
Message Description Type Code Description Measures limit is reached, it is converted to a significant event. E109 BATT OVER VOLTAGE The product stops the generating PROTECTION process because a significant PROTECTION event has occurred. Wait until the event message disappears. After the event message is removed, it automatically returns to normal.
Page 49
Message Description Type Code Description Measures If it is not removed until the time limit is reached, it is converted to a significant event. PROTECTION E203 ON SEQUENCE INV DC While in progress, battery LINK EVENT discharged/charged operation is terminated through the protection function.
Message Description Type Code Description Measures PROTECTION E207 NORMAL INV DC LINK While in progress, battery EVENT discharged/charged operation is terminated through the protection function. Wait until the event message disappears. After the event message is removed, it automatically returns to normal.
Message Description Type Code Description Measures EVENT the protection event. Wait until the event message disappears. After the event message is removed, it automatically returns to normal. If it is not removed until the time limit is reached, it is converted to a significant event.
Message Description Type Code Description Measures If it is not removed until the time limit is reached, it is converted to a significant event. PROTECTION E402 OVER CURRENT TZ Occurs on INVERTER hardware FAULT protection. Wait until the event message disappears.
Page 53
Message Description Type Code Description Measures PROTECTION E504 UNDER VOLTAGE When the minimum cell voltage is PROTECTION-CELL below Protection level, thus terminating the system. Automatically returns to normal when the minimum cell voltage goes above the limit value. WARNING E505 OVER TEMPERATURE.
Message Description Type Code Description Measures WARNING E513 CELL TEMPERATURE Occurs above the standard battery SENSOR 1EA cell temperature. PROTECTION E514 CELL TEMPERATURE Occurs above the standard battery SENSOR 2EA cell temperature. [Table 7-7: BMS general events list] 7.2.7 EMS/Communication Events Type Code Description...
Message Description Type Code Description Measures power system event is settled. E705 GRID TEN MINUTE The operation mode is terminated AVERAGE FAULT when a power system event occurs. Restart 1 minute after the electric power system event is settled. E706 RCMU (Residual Current Turn off system power when the Monitoring Unit) FAULT...
Message Description E903 SINGLE FAULT EVENT The protection device against hazards has a defect or a fault that can cause a hazard has occurred. Contact the installer immediately. E904 CONTINUOUSLY 3 When INVERTER FAULT occurs three TIMES INVERTER FAULT consecutive times, INVERTER HARD FAIL is considered to be occurred to stop the operation.
Chapter 1 Residential Energy Storage Chapter 2 Li-Ion Battery Li-Ion Battery Abbreviation of Samsung Display and Interface Photo voltaic Single phase A type of phase in electricity Distribution Box A box containing AC, DC ON-OFF switches for electricity...
To receive customer support, the following information is required. 1. Product type: ELSR362-00004 2. Serial Number: AR00460036Z1********D 3. PV module type and configuration 4. Option equipment: Energy Meter Model Name ■ Address: 150-20, Gongse-ro Giheung-gueung, Yongin-si 446-557 Gyeonggi-do KOREA, REPUBBLIC OF ■ E-Mail: esseuservice@samsung.com Australia (Eng.) 05/2015. Rev1.1...