Summary of Contents for Olimpia splendid Unico

  • Page 2: Product View/Dimensions

    9 11 6 0 m 6 0 m m...
  • Page 3 UNICO...
  • Page 5 UNICO...
  • Page 6 LED D LED C LED B LED A...
  • Page 7 UNICO...
  • Page 8: Remote Control Overview

    AUTO AUTO...
  • Page 9: Table Of Contents

    3.3.17 Managing the unit if the remote control is not available -------------------------------------------------------------- 38 ENERGY SAVING ADVICE ------------------------------------------------------------------------------------------------- 38 DIAGNOSIS OF THE PROBLEMS --------------------------------------------------------------------------------------- 38 3.5.1 Functional aspects not to be interpreted as problems ---------------------------------------------------------------- 38 3.5.2 Troubleshooting ---------------------------------------------------------------------------------------------------------------- 39 3.5.3 Specifications ------------------------------------------------------------------------------------------------------------------ 40 UNICO...
  • Page 10: Symbols

    GENERAL SYMBOLS The pictograms shown in the next chapter provide the information necessary for correct use of the appliance in a rapid and unmistakable way. 1.1.1 Editorial pictograms Service Refers to situations in which you should inform the SERVICE department in the company: CUSTOMER TECHNICAL SERVICE.
  • Page 11: Warning

    The air-conditioner should be used for the exclusive purpose of producing hot or cool air (on demand) for the sole purpose of obtaining a comfortable temperature in the room. Improper use of the equipment, which may cause injury/damage to persons, property or animals, relieves OLIMPIA SPLENDID of any liability.
  • Page 12: Storage

    3 days of receipt of the goods and enclosing photographic evidence. Send the same information by fax to OLIMPIA SPLENDID. No complaints will be accepted if made more than 3 days after the delivery of the goods.
  • Page 13: Installation Modes

    The UNICO unit may be installed in lieu of a UNICO SKY or UNICO STAR unit without changing the position of the existing holes, with the exception of the small hole for condensate drainage. In this case, in order not to penalize performance, remove the insulating material from the air outlet pipe.
  • Page 14: Preparing The Condensate Discharge

    To prevent the creation of large amounts of dust and rubble due to drilling, the core borer can be fitted with a vacuum system applied by means of suction cups to the drilling zone. Our Service Department can give you all necessary information to enable you to find these devices.
  • Page 15: Preparing The Holes On The Machine

    (minimum cross-section of the cable must be 1.5 mm The appliance is powered exclusively through a socket that is compatible with the plug supplied. WARNING: Any replacement of the power cable must be carried out solely by Olimpia Splendid technical support or by similarly qualified personnel.
  • Page 16: Top/Bottom Installation Configuration

    remove the wooden wedge from behind the unit lock the cable's three poles in the terminal strip and tighten the screws (fig. 19 ref. C) block the cable with the clamp (fig. 19 ref. B) close the protection of the board (fig. 19 ref. A) refit the front cover of the machine with the six screws refit the two wedged-in covers (upper and lower).
  • Page 17: Evacuating Condensate Water During An Emergency

    Explain the contents of the Instruction Manual to the user. Show the user how to clean the filter. 2.6.1 Cleaning the air filter OPERATION TO BE PERFORMED WHEN THE MACHINE IS SWITCHED OFF AND THE POWER SUPPLY IS DISCONNECTED. UNICO...
  • Page 18: Warnings

    To ensure effective internal air filtration and satisfactory operation of your air conditioner, the air filter has to be cleaned periodically. Signalling of the requirement for this important maintenance operation is signalled after a long period of operating by the illumination of the red LED positioned on the signal console.
  • Page 19: Fitting The Batteries

    In order to transmit commands to the indoor unit, point the front of the remote control toward the unit's control panel. The device emits a beep when it receives a command. The maximum distance for transmission of commands is about 8 meters. UNICO...
  • Page 20: Turning The Unit On/Off

    3.3.3 Turning the unit ON/OFF Using button T1 it is possible to switch off (stand-by) or switch on the system. Since the machine's control system has a memory, no setting will not be lost when it is turned off. This button serves to switch the air conditioner on or off for brief periods of time. In case of prolonged stop of the machine, it must be deactivated turning the main switch off or unplugging the machine from the mains.
  • Page 21: Night Well-Being Key

    30 minutes. To return to the routine operating mode just press the button T6 as many times as necessary to clear the relevant indications from the display. UNICO...
  • Page 22: Starting And Stopping The Operating Programs

    User (See paragraph: Anomalies and solutions), while for all of the other anomalies it is necessary to contact the Olimpia Splendid Service Centre. WARNING: Please remember that any attempt to repair the appliance by unauthorised personnel will immediately invalidate any form of guarantee.
  • Page 23: Troubleshooting

    • Remove anything that might clog the air flows. • The heating/cooling load has increased (for example a door or a window was left open or equipment that dissipates a large amount of heat was installed in the same room); UNICO...
  • Page 24: Specifications

    3.5.3 Specifications For the technical data listed below, consult the characteristic data plate applied to the product - Power supply voltage - Maximum power absorbed - Maximum current absorbed - Coolant power - Coolant gas - Protection rating of the containers - Max working pressure Dimensions (W x H x D) mm 902x516x229...
  • Page 25: General Safety Information

    ADDITIONAL INSTRUCTIONS FOR MODEL WITH ELECTRICAL HEATER ELEMENT GENERAL SAFETY INFORMATION Use this appliance solely as described in this manual. Any other use not advised by the manufacturer can result in fire, electric shock or injury. • Ensure that the power supply available complies with the voltage specified on the unit’s rating plate (220-240VAC/50Hz). •...