Sign In
Upload
Manuals
Brands
Mitsubishi Electric Manuals
Inverter
FR-F700PJ Series
Mitsubishi Electric FR-F700PJ Series Manuals
Manuals and User Guides for Mitsubishi Electric FR-F700PJ Series. We have
2
Mitsubishi Electric FR-F700PJ Series manuals available for free PDF download: Instruction Manual, Manual
Mitsubishi Electric FR-F700PJ Series Instruction Manual (356 pages)
Air-conditioning inverter
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 15.94 MB
Table of Contents
Table of Contents
5
1 Outline
15
Product Checking and Parts Identification
15
Inverter Placement (Installation of Filterpack)
16
Inverter and Peripheral Devices
17
Peripheral Devices
18
Removal and Reinstallation of the Cover
19
Front Cover
19
Wiring Cover
21
Installation of the Inverter and Enclosure Design
22
Installation Environment for the Inverter (Filterpack)
22
Cooling System Types for Inverter Enclosure
24
Inverter Placement (Installation of Filterpack)
24
Installation of the Inverter (Without Filterpack)
24
Installation of the Inverter and Filterpack (for Rear Panel Installation)
25
Installation of Filterpack
26
Installation Precautions
28
2 Wiring
30
Terminal Connection Diagram
31
Wiring
31
Main Circuit
31
Control Circuit
31
Main Circuit Terminal Specifications
32
Specification of Main Circuit Terminal
32
Terminal Arrangement of the Main Circuit Terminal, Power Supply and the Motor Wiring
33
Wiring of the Inverter and Filterpack
34
Cables and Wiring Length
35
Control Circuit Specifications
38
Control Circuit Terminal
38
Connection of Stand-Alone Option Unit
39
Changing the Control Logic
40
Wiring of Control Circuit
42
Connection to the PU Connector
45
Connection of Stand-Alone Option Unit
47
Connection of a Dedicated External Brake Resistor (MRS Type, MYS Type, FR-ABR)
47
EMC and Leakage Currents
47
Connection of the Brake Unit (FR-BU2)
49
Connection of the High Power Factor Converter (FR-HC2)
51
Connection of the Power Regeneration Common Converter (FR-CV)
52
Connection of a DC Reactor (FR-HEL)
53
3 Precautions for Use of the Inverter
54
EMC and Leakage Currents
55
Installation of Power Factor Improving Reactor
55
Leakage Currents and Countermeasures
55
Inverter-Driven 400V Class Motor
57
EMC Measures
58
Precautions for Use of the Inverter
58
Power Supply Harmonics
60
Harmonic Suppression Guideline in Japan
61
Installation of Power Factor Improving Reactor
63
Power-OFF and Magnetic Contactor (MC)
64
Inverter-Driven 400V Class Motor
65
Precautions for Use of the Inverter
66
Failsafe of the System Which Uses the Inverter
68
4 Parameters
70
Operation Panel
71
Names and Functions of the Operation Panel
71
Basic Operation (Factory Setting)
72
Easy Operation Mode Setting (Easy Setting Mode)
73
Changing the Parameter Setting Value
74
Displaying the Control Method and the Set Frequency
75
Parameter List
77
IPM Motor Control <IPM
85
Initializing the Parameters Required to Drive an IPM Motor (Pr.998) <IPM
85
Setting Procedure of IPM Motor Control <IPM
85
IPM Motor Control <IPM
88
Setting Procedure of IPM Motor Control <IPM
88
Parameter Setting
89
Initializing the Parameters Required to Drive an IPM Motor (Pr.998) <IPM
90
IPM Motor Test Operation (Pr.800) <IPM
93
Adjusting the Speed Control Gain (Pr.820, Pr.821) <IPM
95
Adjustment of the Output Torque (Current) of the Motor
97
Manual Torque Boost (Pr. 0, Pr. 46)
97
Acquiring Large Starting Torque and Low Speed Torque (General-Purpose Magnetic Flux Vector Control (Pr. 71, Pr. 80))
98
Slip Compensation (Pr. 245 to Pr. 247) <V/F><GP MFVC
100
Stall Prevention Operation (Pr. 22, Pr. 23, Pr. 48, Pr. 66, Pr. 154, Pr. 156, Pr. 157)
101
Starting Frequency
101
Limiting the Output Frequency
106
Maximum/Minimum Frequency (Pr. 1, Pr. 2, Pr. 18)
106
Avoiding Mechanical Resonance Points (Frequency Jumps) (Pr. 31 to Pr. 36, Pr. 552)
107
V/F Pattern
108
Base Frequency, Voltage (Pr. 3, Pr. 19, Pr. 47) <V/F
108
Load Pattern Selection (Pr. 14)
110
Frequency Setting by External Terminals
111
Operation by Multi-Speed Operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
111
Jog Operation (Pr. 15, Pr. 16)
113
Remote Setting Function (Pr. 59)
115
Setting of Acceleration/Deceleration Time and Acceleration/ Deceleration Pattern
118
Setting of the Acceleration and Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 44, Pr. 45, Pr. 791, Pr. 792)
118
Starting Frequency and Start-Time Hold Function (Pr. 13, Pr. 571) <V/F><GP MFVC
121
Minimum Motor Rotation Frequency (Pr.13) <IPM
122
Acceleration/Deceleration Pattern (Pr. 29)
123
Selection and Protection of a Motor
124
Motor Overheat Protection (Electronic Thermal O/L Relay, PTC Thermistor Protection) (Pr. 9, Pr. 51, Pr. 561)
124
Applied Motor (Pr. 71, Pr. 450)
128
(Pr. 71, Pr. 80, Pr. 82 to Pr. 84, Pr. 90, Pr. 96) <GP MFVC
130
Exhibiting the Best Performance for the Motor (Offline Auto Tuning)
130
Motor Brake and Stop Operation
134
DC Injection Brake of General-Purpose Motor Control (Pr. 10 to Pr. 12) <V/F><GP MFVC
134
DC Injection Brake of IPM Motor Control (Pr.10, Pr.11) <IPM
135
Selection of a Regenerative Brake (Pr. 30, Pr. 70)
136
Stop Selection (Pr. 250)
138
Function Assignment of External Terminal and Control
139
Input Terminal Function Selection (Pr. 178 to Pr. 182)
139
Inverter Output Shutoff Signal (MRS Signal, Pr. 17)
141
Condition Selection of Function Validity by Second Function Selection Signal (RT)
142
Start Signal Operation Selection (STF, STR, STOP Signal, Pr. 250)
143
Output Terminal Function Selection (Pr. 190, Pr. 192)
145
Detection of Output Frequency (SU, FU Signal, Pr. 41 to Pr. 43, Pr. 870)
149
Output Current Detection Function (Y12 Signal, Y13 Signal, Pr. 150 to Pr. 153, Pr. 166, Pr. 167)
151
Remote Output Selection (REM Signal, Pr. 495, Pr. 496)
153
Pulse Train Output of Output Power (Y79 Signal, Pr. 799)
154
Monitor Display and Monitor Output Signal
155
Speed Display and Speed Setting (Pr. 37, Pr. 144, Pr. 505)
155
Monitor Display Selection of DU/PU and Terminal FM (Pr. 52, Pr. 54, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891)
157
Reference of the Terminal FM (Pulse Train Output) (Pr. 55, Pr. 56)
162
Terminal FM Calibration (Calibration Parameter C0 (Pr. 900))
163
How to Calibrate the Terminal FM When Using the Operation Panel
164
Operation Selection at Power Failure and Instantaneous Power Failure
166
Automatic Restart after Instantaneous Power Failure/Flying Start under General-Purpose Motor Control
166
V/Fgp Mfvc
166
Automatic Restart after Instantaneous Power Failure/Flying Start under IPM
171
Motor Control (Pr. 57, Pr. 162, Pr. 611) <IPM
171
Power-Failure Deceleration Stop Function (Pr. 261) <V/F><GP MFVC
173
Operation Setting at Fault Occurrence
175
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
175
Earth (Ground) Fault Detection at Start (Pr. 249)
177
Input/Output Phase Loss Protection Selection (Pr. 251, Pr. 872)
177
Overspeed Detection Function (Pr.374)
178
Energy Saving Operation and Energy Saving Monitor
179
Optimum Excitation Control (Pr. 60)
179
Energy Saving Monitor (Pr. 891 to Pr. 899)
180
Motor Noise, EMI Measures, Mechanical Resonance
186
PWM Carrier Frequency and Soft-PWM Control (Pr. 72, Pr. 240, Pr. 260)
186
Speed Smoothing Control (Pr. 653) <V/F><GP MFVC
187
Frequency Setting by Analog Input (Terminal 2, 4)
188
Analog Input Selection (Pr. 73, Pr. 267)
188
Setting the Frequency by Analog Input (Voltage Input)
191
Response Level of Analog Input and Noise Elimination (Pr. 74)
192
Bias and Gain of Frequency Setting Voltage (Current) (Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905))
193
Frequency Setting Signal (Current) Bias/Gain Adjustment Method
195
Misoperation Prevention and Parameter Setting Restriction
198
Parameter Write Disable Selection (Pr. 77)
198
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
198
Parameter Write Disable Selection (Pr. 77)
201
Extended Parameter Display (Pr. 160)
202
Reverse Rotation Prevention Selection (Pr. 78)
202
Password Function (Pr. 296, Pr. 297)
203
Selection of Operation Mode and Operation Location
205
Operation Mode Selection (Pr. 79)
205
Setting the Frequency by the Operation Panel
214
Setting the Frequency by the Operation Panel (Pr. 79 = 3)
216
Setting the Frequency by Analog Input (Voltage Input)
217
Operation Mode at Power-ON (Pr. 79, Pr. 340)
218
Start Command Source and Frequency Command Source During Communication Operation (Pr. 338, Pr. 339, Pr. 551)
219
Communication Operation and Setting
223
Wiring and Configuration of PU Connector
223
(Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549)
226
Initial Settings and Specifications of RS-485 Communication
226
Initial Settings and Specifications of RS-485 Communication (Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549)
226
Operation Selection at Communication Error Occurrence (Pr. 121, Pr. 122, Pr. 502, Pr. 779)
227
Communication EEPROM Write Selection (Pr. 342)
230
Mitsubishi Inverter Protocol (Computer Link Communication)
231
Run Command
241
Modbus-RTU Communication Specifications (Pr. 117, Pr. 118, Pr. 120, Pr. 122, Pr. 343, Pr. 502, Pr. 549, Pr. 779)
243
PID Control (Pr. 127 to Pr. 134, Pr. 553, Pr. 554, Pr. 575 to Pr. 577, C42 to C45)
255
Special Operation and Frequency Control
255
Function Description
259
Regeneration Avoidance Function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)
267
Cooling Fan Operation Selection (Pr. 244)
269
Useful Functions
269
Display of the Lives of the Inverter Parts (Pr. 255 to Pr. 259)
270
Maintenance Timer Alarm (Pr. 503, Pr. 504)
273
Current Average Value Monitor Signal (Pr. 555 to Pr. 557)
274
Free Parameter (Pr. 888, Pr. 889)
276
Initiating a Fault (Pr.997)
277
Setting Multiple Parameters as a Batch (Pr.999)
278
PU Display Language Selection (Pr. 145)
282
RUN Key Rotation Direction Selection (Pr. 40)
282
Setting the Parameter Unit and Operation Panel
282
Frequency Setting
283
Setting Dial Potentiometer Mode/Key Lock Selection (Pr. 161)
283
Magnitude of Frequency Change Setting (Pr. 295)
286
Buzzer Control (Pr. 990)
287
PU Contrast Adjustment (Pr. 991)
287
Built-In Potentiometer Switching (Pr. 146)
288
FR-E500 Series Operation Panel (PA02) Setting
288
Bias and Gain of the Built-In Frequency Setting Potentiometer (C22 (Pr. 922) to C25 (Pr. 923))
289
Parameter Clear/ All Parameter Clear
295
Initial Value Change List
296
Check and Clear of the Faults History
297
5 Troubleshooting
300
Reset Method of Protective Function
301
List of Fault or Alarm Indications
302
Causes and Corrective Actions
303
Correspondences between Digital and Actual Characters
313
Check First When You Have a Trouble
314
Motor Does Not Start
314
Motor or Machine Is Making Abnormal Acoustic Noise
316
Inverter Generates Abnormal Noise
317
Motor Generates Heat Abnormally
317
Motor Rotates in the Opposite Direction
317
Speed Greatly Differs from the Setting
317
Acceleration/Deceleration Is Not Smooth
318
Speed Varies During Operation
318
Motor Current Is too Large
319
Operation Mode Is Not Changed Properly
319
Operation Panel Display Is Not Operating
319
Speed Does Not Accelerate
320
Unable to Write Parameter Setting
320
6 Precautions for Maintenance and Inspection
323
Inspection Items
323
Daily Inspection
323
Periodic Inspection
323
Daily and Periodic Inspection
324
Checking the Inverter and Converter Modules
325
Cleaning
325
Display of the Life of the Inverter Parts
325
Replacement of Parts
326
Measurement of Main Circuit Voltages, Currents and Powers
329
Measurement of Powers
331
Measurement of Voltages and Use of PT
331
Measurement of Converter Output Voltage (Across Terminals P and N)
332
Measurement of Currents
332
Measurement of Inverter Input Power Factor
332
Measurement of Inverter Output Frequency
332
Use of CT and Transducer
332
Insulation Resistance Test Using Megger
333
Pressure Test
333
7 Specifications
334
Rating
335
Common Specifications
336
Outline Dimension Drawings
338
Specification of the Premium High-Efficiency IPM Motor [MM-EFS (1500R/Min) Series]
344
Specification of the Premium High-Efficiency IPM Motor [MM- EFS (1500R/Min) Series]
344
Motor Specification
345
Specification of Dedicated IPM Motor [MM-EF(1800R/Min) Series]
345
Appendix
346
Appendix 1 for Customers Replacing the Conventional Model with this Inverter
347
Appendix 1-1 Replacement of the FR-F500J Series
347
Appendix 2 Options and Products Available on the Market
349
Appendix 3 Specification Change
351
Changed Functions
351
Appendix 4 Index
352
Advertisement
Mitsubishi Electric FR-F700PJ Series Manual (96 pages)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 13.26 MB
Table of Contents
Table of Contents
3
Features
5
Connection Example
10
Standard Specifications
11
Outline Dimension Drawings
14
Terminal Connection Diagram, Terminal Specification Explanation
17
Explanation of Operation Panel, Parameter Unit, FR Configurator
20
Parameter List
24
Explanation of Parameters
33
Protective Functions
57
Options and Peripheral Devices
59
Precautions for Operation/Selection, Precautions for Peripheral Device Selection
70
Application to Motor
76
IPM Motor Control
80
Main Differences and Compatibilities with the FR-F500J Series
84
Warranty, Global FA Centers
86
Advertisement
Related Products
Mitsubishi Electric FR-F700 Series
Mitsubishi Electric FR - F700
Mitsubishi Electric FR-F740P-45K
Mitsubishi Electric FR-F740-06830-EC
Mitsubishi Electric FR-F740-00930-NA
Mitsubishi Electric FR-F746-00310-EC
Mitsubishi Electric FR-F720PJ-1.5KF
Mitsubishi Electric FR-F720PJ-5.5K
Mitsubishi Electric FR-F 740-06830-EC
Mitsubishi Electric FR-F 740-00126-EC
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL