Sign In
Upload
Manuals
Brands
Samsung Manuals
Air Conditioner
AM036JNADKH/EU
Samsung AM036JNADKH/EU Manuals
Manuals and User Guides for Samsung AM036JNADKH/EU. We have
2
Samsung AM036JNADKH/EU manuals available for free PDF download: Service Manual
Samsung AM036JNADKH/EU Service Manual (552 pages)
System
Brand:
Samsung
| Category:
Air Conditioner
| Size: 52.02 MB
Table of Contents
Table of Contents
2
Precautions
7
Precautions for the Service
7
Precautions for the Static Electricity and PL
7
Precautions for the Safety
7
Precautions for Handling Refrigerant for Air Conditioner
8
Precautions for Welding the Air Conditioner Pipe
8
Precautions for Additional Supplement of Air Conditioner Refrigerant
8
Other Precautions
8
Product Specifacations
9
Indoor Unit
9
Slim 1Way Cassette Type
9
Way Cassette Type
13
Way Cassette
14
Global 4Way Cassette(600X600)
16
4Way Cassette(600X600)
18
Slim Duct
19
GD-S(Big Duct)
19
Slim Home Duct
20
Duct Type (Uplevel Static Pressure)
21
MSP Duct
22
Cassette
23
Big Duct
24
Global Duct (Cont.)
24
GD-S(Big Duct)
25
HSP Duct
26
Global Duct
27
Ceiling Type
32
Big Ceiling
33
Console Type
34
Wall Mounted Type(Neo Forte Without EEV)
35
Wall Mounted Type(Boracay Without EEV)
35
Wall Mounted Type(Neo Forte with EEV)
36
Wall Mounted Type(Boracay with EEV)
37
Wall Mounted Type(Boracay with EEV)
38
Wall Mounted Type(Boracay Without EEV)
39
Wall Mounted Type(Boracay Without EEV)
41
Floor Standing Type
43
Floor Standing Type
44
ERV Plus
45
Hydro Unit
46
Hydro Unit HT
47
Wall Mounted Type(A3050 with EEV)
48
Wall Mounted Type(A3050 with EEV)
50
Wall Mounted Type(A3050 Without EEV)
52
Wall Mounted Type (MAX with EEV)
54
Fresh Air Duct
55
V-Ahu
56
Oap Duct
60
Ehs Tdm Plus - Slim Duct
61
Ehs Tdm Plus - Global Duct
62
EHS TDM PLUS -Console Type
63
EHS TDM PLUS -Wall Monuted Type
64
Accessory and Option Specifications
66
Accessories
66
Disassembly and Reassembly
69
Necessary Tools
69
Indoor Unit
70
Am017/022Hn1Deh/Eu
70
Am017/022Nn1Peh/Eu
73
Slim 1 Way Cassette Type
80
Am022/028/036Nn1Deh/Eu
82
Am056/071Nn1Deh/Eu
85
Am052/060/072Fn1Dbh, Am052/060/072Hn1Dbh1, Am056/071Fn1Deh, Am056/071Jn1Deh
95
Big Duct
102
GD-S(Big Duct) - AM180JNHFKH/AM224JNHFKH
105
Global 4Way Cassette Type
116
Duct Type(Slim1,2)
131
Duct Type(Slim3)
136
Slim Home Duct
143
Duct Type(MID Pressure1)
148
Duct Type (MID Pressure2, High Pressure)
153
Am036/045/056/071/090/112/128/140Hnmpkh, Am112/128/140Hnhpkh/Eu, Ae071/090Mnmpeh/Eu
158
Ceiling
163
Am112/140Jncdkh/Eu
172
Console
177
Erv Plus
182
Floor Standin Type
191
Wall Mount Type
195
Wall Mounted Type (Boracay)
198
Wall Mounted Type (MAX)
202
Global 4Way Cassette Type(600X600)
210
Am160Fnbdeh/320Fnbdeh/500Fnbdeh
216
Am160/250Fnbfeb, Am160/250Fnbfgb
220
Wall Mounted Type(A3050)
226
Oap Duct
235
OAP Duct (AM140MNEPEH/EU)
237
OAP Duct (AM220/280MNEPEH/EU)
244
V-Ahu
249
Am280Jnpdkh/Tk
254
Am140Jnpdkh/Tk
260
4Way Cassette Type
268
Troubleshooting
271
Check-Up Window Description
271
Service Operation
272
Special Operation
272
DVM S Models EEPROM Code Table
276
Troubleshooting
277
Setting Option Setup Method
277
Option Items
293
What to Check before Diagnosis
301
Floor Standing Type
313
ERV Plus Type
315
Hydro Unit / Hydro Unit HT
316
Number Display Method (Outdoor Unit, MCU, Cable Remote Control, Wall-Mount, Etc.)
317
Appropriate Measures for Different Symptom
323
Outdoor Unit Operation Flow
323
Main PCB Has no Power Phenomenon
324
Indoor Unit ROOM Sensor Error (Open/Short)
325
Indoor Unit EVAP in Sensor Error (Open/Short)
326
Indoor EVAP out Sensor Error (Open/Short)
327
Indoor Heat Exchanger's EVAP in Sensor Dislocation Error
328
Indoor Heat Exchanger's EVA out Sensor Dislocation Error (Open/Short)
329
Simultaneous Indoor Heat Exchanger's EVA IN, out Sensor Dislocation Error (Open/Short)
330
Electronic Expansion Valve Opening Malfunction (2Nd Stage)
331
Breakdown of EEV (2 Nd )
332
Problem with EEV Closure (2 Nd )
333
Eev(Electronic Expansion Valve) Opening Malfunction (2Nd Stage)
334
Eev(Electronic Expansion Valve) Closure Malfunction (2Nd Stage)
335
Detection of Floating Switch of Indoor Unit's Drain Pump
336
The Operational Error of Indoor Unit's Fan Motor
337
Mixed Operation Error (Only Applicable to Heat Pump Model/Not to HR Model)
338
EEPROM Error
339
Option Error of the Remote Controller for an Indoor Unit
340
Error Due to Confused Use of Fahrenheit and Celsius
340
St Nd
341
Error Due to Incorrect Indoor Unit Power/Communication Cable Connection
342
SPI Feedback Error
343
Outdoor Unit Pipe Inspection Error
344
Communication Error between Indoor and Outdoor Units During Tracking
345
Communication Error between Indoor and Outdoor Units after Tracking
346
Communication Error between Main and Sub Unit of Outdoor Unit or between Outdoor Units
347
Communication Error between MCU and Outdoor Unit
348
Internal Communication Error of the Outdoor Unit C-Box
349
Internal PCB Communication Error of the Outdoor Unit C-Box
350
Communication Error between MCU and Outdoor Unit after Tracking Is Completed
351
MCU Branch Part Setup Error - Inconsecutive Connection with the Use of 2 Branch Parts
352
MCU Branch Part Setup Error - Repeated Setup for the same Address over 3 Times
353
MCU Branch Part Setup Error - Non-Installed Address Setup
354
Setup Error for MCU Branch Part - Setup Error for MCU Quantity Used
355
MCU Branch Part Setup Error - Overlapping Indoor Unit Address Setup
356
MCU Branch Part Setup Error - Set as Being Used Without Connection to an Indoor Unit
357
MCU Branch Part Setup Error - Connect an Indoor Unit to a Branch Part Not Being Used
358
MCU Branch Part Setup Error - Connect more Indoor Units than What Is Actually Set up in MCU
359
Outdoor Temperature Sensor Error
360
Outdoor Temperature Dislocation Error
361
Cond out Temperature Sensor Error (Open/Short)
362
Outdoor Cond out Sensor Breakaway Error
363
Digital Compressor Discharge Temperature Sensor Error (OPEN/SHORT)
364
Constant Rate Compressor Discharge Temperature Sensor Error (OPEN/SHORT)
365
Compressor Discharge or Top 1/2 Temperature Sensor Error
366
Dislocation Error of Compressor SUMP Temperature (Oil Temperature) Sensor
367
Suction Temperature Sensor Breakaway Error
368
SUMP Temperature Sensor Error (OPEN/SHORT)
369
High Pressure Sensor Error (Open/Short)
370
Low Pressure Sensor Error (Open/Short)
371
Suction Temperature Sensor Error (Open/Short)
372
Liquid Pipe Temperature Sensor Error (Open/Short)
373
EVI in Temperature Sensor Error (Open/Short)
374
EVI out Temperature Sensor Error (Open/Short)
375
Suction-2 Temperature Sensor Error (OPEN/SHORT)
376
Comp. down Due to High Pressure Protection Control
377
Comp. down Due to Low Pressure Protection Control
378
Sump Sensor Error Due to Protection Control
379
Comp. down Due to Compressor Discharge Temperature Sensor
380
3-Phase Input Wiring Error
381
Comp. down by Compression Ratio Control
382
EVI EEV Open Error
383
Refrigerant Leakage Error
384
Prohibition of the Operation of Compressor Due to Ooutdoor Temperature
385
High Pressure Standard Not Met before Air Conditioning (Inability to Re-Operate)
386
CCH Malfunction and Sump Sensor Miswiring Error
387
Fan Starting Error
388
Fan Lock Error
389
Momentary Blackout Error
390
Outdoor Fan Motor Overheating
391
Outdoor Unit Fan Motor RPM Error
392
Fan IPM Overheat Error
393
Over-Voltage Error of an Outdoor Fan Motor
394
Counter-Rotation Error of an Outdoor Fan Motor
394
Compressor Excess Current Error
395
Compressor Starting Error
396
Inverter Overcurrent Error
397
Overvoltage / Low Voltage Error
398
DC Link Voltage Sensor Error
399
Liquid Compression Prevention Control
400
Fan Motor Overcurrent Error
401
Input / Output Current Sensor Error
402
Outdoor Fan PCB Overvoltage / Low Voltage Error
403
Hall IC(Fan) Error
404
Inverter Overheat Error
405
Model Mismatching of Indoor Unit
406
Breakdown of an EEV(1 St )
407
Breakdown of an EEV Closure
408
Electronic Expansion Valve Closing Malfunction (2 Nd Stage)
409
Electronic Expansion Valve Opening Malfunction (2 Nd Stage)
410
Hydro Unit Water in Temperature Sensor Error (Open/Short)
411
Hydro Unit Water out Temperature Sensor Error (Open/Short)
412
Hydro Unit Water Tank Temperature Sensor Error (Open/Short)
413
Emergency Error (Check the Water Piping Equipment)
414
Error to Prevention from Freezing and Bursting of Heat Exchanger
415
Breakaway of Water out Temperature Sensor
416
Breakaway of Flow Switch
417
Thermostat Wiring Error
418
DC FAN Motor Feedback Error
419
Water Tank Sensor Defective
420
PCB Diagram and Parts List
421
Indoor Unit
421
Slim 1 Way Cassette Type (Medium)
421
Way Cassette Type
423
4Way Cassette , Global 4Way Cassette Type(600X600), Slim 1Way Cassette (Small/Large)
425
Cassette
427
Indoor Unit Power PCB
429
Display PCB
430
Duct Type (Slim Duct 2)
431
Duct Type (Slim Duct 3)
434
Slim Home Duct
437
Duct Type(MSP, HSP, Big Duct)
439
Duct Type(HSP)
441
Duct Type (Super)
443
Duct Type (Global Duct)
445
Duct Type (Global Duct_Hsp)
448
Big Duct
451
Celing Type
454
Big Ceiling
456
Console
458
Wall-Mounted Type (Neo Forte)
462
Wall-Mounted Type (Boracay)
464
ERV Plus
466
Hydro Unit/Hydro Unit HT
468
Hydro Unit HT
470
Wall Mounted Type(A3050 )
477
Oap Duct
480
Oap Duct
482
V-Ahu
489
Stand
491
Floor Standing Type
498
Wall Mounted Type(MAX)
502
Wall Mounted Type(MAX)
505
Wind-Free 1Way Cassette Type
507
4Way Cassette(600X600)
510
4Way Cassette(600X600)
512
Wiring Diagram
513
Indoor
513
Global 4Way (Global 4Way(600X600)) Cassette Type, Slim 1Way Cassette (Small/Large)
513
Slim 1 Way Cassette Type (Medium)
514
Cassette
515
BIG Duct
516
GD-S(Big Duct)
517
Ceiling
518
Big Ceiling
519
Console
520
Rac(Neo Forte)
521
Wall-Mounted Type (Boracay)
522
2Way Cassette Type
523
DUCT Type (Slim III)
524
DUCT Type (Slim I, II, MSP)
525
Slim Home Duct
526
Duct Type (HSP)
527
Duct Type (Global Duct, MSP)
528
Duct Type (Global Duct, HSP)
529
Floor Stand Type
530
ERV Plus
532
Hydro Unit
533
Hydro Unit HT 3 Phase
534
Hydro Unit HT Single Phase
535
Wall Mounted Type(A3050)
536
Wall Mounted Type(MAX)
537
Oap Duct(Am140Jnepeh/Eu)
538
OAP Duct (AM140MNEPEH/EU)
539
OAP Duct (AM140MNEPEH/EU)
540
Oap Duct(Am220/280*Nepeh/Eu)
541
V-Ahu
542
Stand
543
4Way Cassette Type(600X600)
547
Reference Sheet
548
Index for Model Name
548
Indoor Unit
548
Panel
549
Pump-Down Method
550
Precautions for Pump-Down
550
For Single Installation of Outdoor Unit (Only One Outdoor Unit Installed)
550
When Two or more Outdoor Units Are Installed
550
How to Put Refrigerant in Refrigerant Container
551
How to Put Refrigerant in Container before Pump-Down
551
Advertisement
Samsung AM036JNADKH/EU Service Manual (335 pages)
Indoor Unit
Brand:
Samsung
| Category:
Air Conditioner
| Size: 14.22 MB
Table of Contents
Contents
1
Table of Contents
2
Precautions for the Static Electricity and PL
4
Precautions for the Safety
4
Precautions for Handling Refrigerant for Air Conditioner
5
Precautions for Welding the Air Conditioner Pipe
5
Precautions for Additional Supplement of Air Conditioner Refrigerant
5
Other Precautions
5
2 Product Specifications
6
Indoor Unit
6
Slim 1Way Cassette Type
6
Mini 4 Way Cassette
11
Slim Duct
14
Big Duct
18
HSP Duct
19
Ceiling Type
20
Console Type
21
Wall Mounted Type(Neo Forte Without EEV)
22
Wall Mounted Type(Neo Forte with EEV)
23
Accessory and Option Specifications
30
3 Disassembly and Reassembly
33
Necessary Tools
33
Indoor Unit
34
Slim 1 Way Cassette Type (Large)
43
Big Duct
50
Global 4Way Cassette Type
53
Cassette
59
Duct Type(Slim1,2)
68
Duct Type(Slim3)
73
Duct Type(MID Pressure1)
80
Duct Typeduct Type (MID Pressure2, High Pressure)
85
Ceiling
90
Console
99
Erv Plus
104
Floor Standin Type
113
Wall Mounted Type(Neo Forte Without EEV)
117
Wall Mounted Type(A3050 with EEV)
120
Global Mini 4Way
129
GD-S(Big Duct)
135
Slim 1 Way Cassette Type (Medium)
34
4 Troubleshooting
146
Check-Up Window Description
146
Service Operation
147
Special Operation
147
Commissioning
148
Refrigerant Filling Operation
148
Heating Pump out
149
Cooling Pump down
149
Vacuum Operation
150
Piping Inspection Operation
150
Discharge Mode Operation
150
Forced Defrost Operation
151
Forced Oil Recovery Operation
151
Setting Option Setup Method
152
PCB Option Code Input Method
152
Entering Mode to Set Option
152
The Procedure of Option Setting
152
Troubleshooting
152
The Procedure of Setting Option
153
Setting SEG2, SEG3 Option
153
Setting SEG4, SEG5 Option
153
Setting SEG6, SEG8 Option
153
Setting SEG14, SEG15 Option
154
Setting Cool Mode
154
Setting SEG16, SEG17 Option
154
Setting Dry Mode
154
Check the Option You Have Set
155
Input Option
155
Check Operation
155
Setting an Indoor Unit Address and Installation Option
156
360 Cassette
158
Common Steps for Setting the Addresses and Options
158
Installation Options for the 02 Series
163
Installation Options for the 02 Series (Detailed)
164
Installation Options for the 05 Series
167
Option Items
168
What to Check before Diagnosis
172
Lamp Combination Expression Method Display
172
Error Detection and Restart
172
LED Lamp Display with Error Detection
172
Global 4Way Cassette Type
174
Duct Type
178
Indoor Unit LED Lamp Display at Error Detecting
180
Wall-Mounted Type
182
Floor Standing Type
183
ERV Plus Type
185
Number Display Method
186
How to Display Integrated Error Code
186
Diagnosis and Adjustment
187
Appropriate Measures for Different Symptom
191
Outdoor Unit Operation Flow
191
Main PCB Has no Power Phenomenon
192
Indoor Unit ROOM Sensor Error
193
Indoor Unit EVAP in Sensor Error
194
Indoor EVAP out Sensor Error
195
Indoor Heat Exchanger's EVAP in Sensor Dislocation Error
196
Breakdown of EEV
200
Problem with EEV Closure
201
Detection of Floating Switch of Indoor Unit's Drain Pump
202
The Operational Error of Indoor Unit's Fan Motor
203
Mixed Operation Error
204
EEPROM Error
205
Option Error of the Remote Controller for an Indoor Unit
206
Error Due to Confused Use of Fahrenheit and Celsius
206
Simultaneous Opening of Cooling/Heating MCU SOL Valves 1
207
Error Due to Incorrect Indoor Unit Power
208
Communication Cable Connection
208
SPI Feedback Error
209
Outdoor Unit Pipe Inspection Error
210
Communication Error between Indoor and Outdoor Units During Tracking
211
Communication Error between Indoor and Outdoor Units after Tracking
212
Communication Error between Main and Sub Unit of Outdoor Unit or between Outdoor Units
213
Communication Error between Mcu and Outdoor Unit
214
Communication Error between Mcu and Outdoor Unit after Tracking Is Completed
217
MCU Branch Part Setup Error
218
Setup Error for MCU Branch Part – Setup Error for MCU Quantity Used
221
MCU Branch Part Setup Error – Overlapping Indoor Unit Address Setup
222
Outdoor Temperature Sensor Error
226
Outdoor Temperature Dislocation Error
227
Cond out Temperature Sensor Error
228
Outdoor Cond out Sensor Breakaway Error
229
Digital Compressor Discharge Temperature Sensor Error
230
Constant Rate Compressor Discharge Temperature Sensor Error
231
Compressor Discharge or Top 1/2 Temperature Sensor Error
232
Dislocation Error of Compressor SUMP Temperature Sensor
233
Suction Temperature Sensor Breakaway Error
234
SUMP Temperature Sensor Error
235
High Pressure Sensor Error
236
Low Pressure Sensor Error
237
Suction Temperature Sensor Error
238
Liquid Pipe Temperature Sensor Error
239
EVI in Temperature Sensor Error
240
Suction-2 Temperature Sensor Error
242
Comp. down Due to High Pressure Protection Control
243
Comp. down Due to Low Pressure Protection Control
244
Sump Sensor Error Due to Protection Control
245
Comp. down Due to Compressor Discharge Temperature Sensor
246
3-Phase Input Wiring Error
247
Comp. down by Compression Ratio Control
248
EVI EEV Open Error
249
Refrigerant Leakage Error
250
Prohibition of the Operation of Compressor Due to Ooutdoor Temperature
251
CCH Malfunction and Sump Sensor Miswiring Error
253
Fan Starting Error
254
Fan Lock Error
255
Momentary Blackout Error
256
Outdoor Fan Motor Overheating
257
Outdoor Unit Fan Motor RPM Error
258
Fan IPM Overheat Error
259
Over-Voltage Error of an Outdoor Fan Motor
260
Counter-Rotation Error of an Outdoor Fan Motor
260
Compressor Excess Current Error
261
Compressor Starting Error
262
Inverter Overcurrent Error
263
Overvoltage / Low Voltage Error
264
DC Link Voltage Sensor Error
265
Liquid Compression Prevention Control
266
Fan Motor Overcurrent Error
267
Input / Output Current Sensor Error
268
Outdoor Fan PCB Overvoltage / Low Voltage Error
269
Hall IC(Fan) Error
270
Inverter Overheat Error
271
Model Mismatching of Indoor Unit
272
Breakdown of an EEV
273
Breakdown of an EEV Closure
274
Electronic Expansion Valve Closing Malfunction
275
Electronic Expansion Valve Opening Malfunction
276
5 PCB Diagram and Parts List
277
2 Way Cassette Type
279
Way Cassette Type
280
4Way Cassette , Mini 4Way Casette Type, Slim 1 Way Cassette Type (Large)
281
Cassette
283
Indoor Unit Power PCB
285
Display PCB
286
Duct Type (Slim Duct 2)
287
Duct Type (Slim Duct 3)
290
Duct Type(MSP, HSP, Big Duct)
293
Duct Type (Super)
297
Celing Type
299
Console
301
Wall-Mounted Type (Neo Forte)
305
Wall Mounted Type(A3050)
307
ERV Plus
310
GD-S (Big Duct)
312
6 Wiring Diagram
315
Indoor
315
Global 4Way(Global Mini-4Way) Cassteet Type, Slim 1Way Cassette (Large)
315
Slim 1 Way Cassette Type (Medium)
316
Cassette
317
BIG Duct
318
Ceiling
319
Console
320
Wall Mounted Type(Neo Forte Without EEV)
321
Wall Mounted Type(A3050)
322
2Way Cassette Type
323
DUCT Type (Slim III)
324
DUCT Type (Slim I, II, MSP)
325
Duct Type (HSP)
326
Floor Stand Type
327
ERV Plus
328
GD-S (Big Duct)
329
7 Reference Sheet
330
Index for Model Name
330
Indoor Unit
330
Panel
331
Pump-Down Method
332
Precautions for Pump-Down
332
When Two or more Outdoor Units Are Installed
332
For Single Installation of Outdoor Unit (Only One Outdoor Unit Installed)
332
How to Put Refrigerant in Refrigerant Container
333
How to Put Refrigerant in Container before Pump-Down
333
Advertisement
Related Products
Samsung AM036JNADKH
Samsung AM036JNADKH/TS
Samsung AM036JNADEU
Samsung AM036JNHDCH/AA
Samsung AM036JNCDCH/AA
Samsung AM036JNCDCH
Samsung AM036JNVDKH
Samsung AM036JNZDCH/AA
Samsung AM036JNVDKH/TS
Samsung AM036JNVDEU
Samsung Categories
Cell Phone
Monitor
Microwave Oven
Air Conditioner
LCD TV
More Samsung Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL