Sign In
Upload
Manuals
Brands
Siemens Manuals
Control Unit
LMU64 Series
Siemens LMU64 Series Manuals
Manuals and User Guides for Siemens LMU64 Series. We have
1
Siemens LMU64 Series manual available for free PDF download: Basic Documentation
Siemens LMU64 Series Basic Documentation (171 pages)
Boiler Management Unit (BMU)
Brand:
Siemens
| Category:
Control Unit
| Size: 1.24 MB
Table of Contents
Table of Contents
3
1 Overview
10
Brief Description
10
System Concept
10
Features
11
Safety Functions
11
Supervision / Protective Functions for the Plant
11
Auxiliary Modules (Clip-In)
11
Dhw
12
Heating Circuit
12
System Application
12
Operation / Service
12
Parameterization
13
Mains Transformer
13
Other Features
13
Product Range
13
Field of Use
13
Target Market
13
Heating Plants
13
Heat Generating Equipment
13
Notes on Product Liability
14
Notes on Environmental Protection
14
Disposal Notes
14
2 Product Range Overview
15
3 Functions
17
Burner Control
17
Program Selection
17
Eeprom
17
Forced Intermittent Operation
17
Burner Control Program
17
Sequence Diagram
18
Capacity Range < 70 Kw
18
Capacity Range 70
18
Capacity Range > 120 Kw
19
Description of Sequence Diagrams
19
Sequence Times
20
Standby
20
Startup
20
Shutdown
22
Home Run
22
Special Cases (Deviations)
22
Lmu
24
Parameterization of Speed Feedback Signal
24
Fan Parameters Accessible Via QAA
25
The Different Capacity Ranges
26
Setting the Fan Parameters During Startup and Shutdown
27
Speed Readjustment
28
Selection of the Compensation Variants
30
Heating Circuits
30
Room Setpoint
32
Configuration of the Heating Circuits
34
DHW Circuit
35
Acquisition of Actual Values
37
Assignment of Analog Sensors
37
Temperatures
37
Display of Ionization Current
38
Supervisory Functions
39
Temperature Limiter Function
39
Flue Gas Temperature Supervision
39
Plausibility Check of Sensor
39
Function
39
Electronic (S)LT
40
Handling Faults
40
Flow Switch / Water Pressure Supervision
42
Function of Flow Switch
42
Function of Pressure Switch
42
Pressure Sensor
42
Static Supervision
43
Dynamic Supervision
44
Load Limitation
45
Speed Limitation
48
Limitation of Ionization Current
48
Boiler Control
49
Frost Protection for the Boiler
49
Controller Delay
49
Controller Delay Due to Parameterization
49
Controller Delay Due to SLT Criterion
50
Controller Configuration
50
Transfer of Setpoint / Actual Value
50
Determining the Controller Coefficients
50
Heat Output Limits
51
Boiler Temperature Control
52
2-Position Control
52
Minimum Boiler Pause Time
52
Boiler Cycling Protection
52
Dynamic Switch-Off Differential
53
Modulating Control, Conventional
54
Hydraulic System Management (HSM)
55
Frost Protection for the Plant
55
Consumer Management (CM)
56
Determining the Demands for Heat
56
Priorization of Demands for Heat
56
Determining the Temperature Demand
57
Temperature Limitation
58
Summer / Winter (S / W) Changeover
59
Electronically Controlled PWM Heating Circuit Pump
61
General
61
Introduction
61
Notes
61
Task of ∆T Control with PWM Pump
61
First Stage Maximum Limitation of the Flow Temperature
62
Second Stage ∆T Limitation
62
Third Stage ∆T Supervision
63
PWM Pump Control
63
H-Q Chart (Example)
63
Adaption of Modulating Pump to the Heating Plant
64
Parametes of the PWM Pump (OEM)
64
Preset Parameters
64
Activation of PWM Pump Via a Configuration Byte
65
Parameters of the PWM Pump (Installer)
66
Parameters for Temperatures
66
PID Controller Coefficients of Delta-T Supervision
67
Summary of All ∆T Parameters
67
Behavior in Different Operating Modes
68
Pump Overrun
68
Normal Operation (Heating Operation)
68
Reduced (Setback) Operation
68
Shutdown Mode
68
Heating up Phase
68
DHW Operation
69
Heating Circuit Control
70
Attenuated Outside Temperature
70
Composite Outside Temperature
71
Type of Building Construction
71
Heating Curves
72
Generating the Demands for Heat
73
Time Switch
74
Room Thermostat
75
Combinations of RU and Room Thermostat / Time Switch
76
ECO Functions
77
S / W Changeover
77
Automatic 24-Hour Heating Limit
77
Quick Setback Constant (KON)
78
Generating the Temperature Demands
78
With Fixed Value Control or Emergency Operation
78
With Weather Compensation
78
4 Clip-In AGU2.500
79
Functions
79
General
79
Hydraulic Diagrams
79
Sensor Inputs (Analog Inputs)
79
Inputs / Outputs
79
Interfaces for the LMU
80
Sensor
80
Frost Protection
80
Overtemperature Protection
80
Mixing Circuits
80
Determining the Flow Temperature Setpoint
80
Handling the Locking Signal
80
Handling the Forced Signal
80
Flow Temperature Control
80
Pump Control
81
Pump Control with Pump Circuits
81
Pump Control with Mixing Circuits
81
Pump Overrun
81
Pump Kick
81
Mixing Valve Control
81
Position of Mixing Valve in the Idle State
81
Functional Test
81
5 Clip-In Module OCI420
82
Functions
82
General
82
Inputs / Outputs
82
Interfaces to LMU
82
Connection of LMU
82
Additional Heating Circuit Extensions Via ALBATROS Controllers
82
Automatic Changeover of Operating Mode
83
Giving Consideration to Heat Demand from the RVA
83
Locking and Forced Signals When Connecting to the LPB
83
External DHW Heating by ALBATROS Controllers
83
Type of Priority of DHW Heating
84
Multiboiler Plants with LMU (Cascade Applications)
84
Separate DHW Circuit in Cascade Applications
85
Operation with the RVA65
85
System Functions
86
Uniform System Time
86
Error / Diagnostic Messages from the LMU
86
Outside Sensor, Outside Temperature Sensor
88
Assignment of Address Numbers
88
Setting the LPB Device and Segment Address
88
6 Clip-In Function Module Agu2.51X
89
Functions
89
General
89
Outputs
89
Number of Available Outputs
89
Inputs
90
Digital Input
90
Analog Input
90
Predefined Setpoint (Temperature Demand)
90
Predefined Output
91
Sensor Input "Pressureless Header
91
7 DHW Control (BWR)
93
Boiler Temperature Setpoint During DHW Heating with Storage Tank
93
Systems
93
DHW Temperature Control
94
Compensation Variants
94
Position of Diverting Valve
95
Storage Tank Systems
95
Stratification Storage Tank
96
Instantaneous DHW System
100
Notes
100
Hydraulic Diagram
100
Operating Mode
100
Outlet Temperature Control (FS-DHW Is Closed)
100
Comfort Control (after FS-DHW Opening)
100
Aqua-Booster System
103
Hydraulic Diagram
103
Operating Mode
103
Outlet Temperature Control
103
Comfort Control
103
Legionella Function
104
Special Functions
105
Forced Signals
105
Parameterization
105
Via PC Tool ACS420 and OCI490
105
Via QAA73
105
Via AGU2.361 / AGU2.303
106
Programmable Input of the LMU
106
Modem Function
106
Warm Air Curtain Function
106
Programmable Output of the LMU
107
Status Output
107
Alarm Output
107
Operational Status Signal
107
Switching off the External Transformer
108
Pump Output Second Heating Circuit
108
DHW Circulating Pump
108
Actuating Device with Warm Air Curtain Function Activated
108
Pump of Pressureless Header
108
Basic Function of Controller Clip-In Module
108
Actuating Device with Full DHW Charging Activated
108
Actuating Device When Analog Signal Exceeds Threshold
109
Power Concept
109
8 Basic Diagram
110
Lmu
110
9 Connection Diagrams
111
Lmu
111
DHW Stepper Motor (Bipolar)
112
Agu2.104A109
112
Agu2.500A109
113
Agu2.500A209
114
Oci420A109
115
Oci420A209
116
Agu2.51X
117
Connecting Cable between OCI490
118
Mounting, Electrical Installation and Service
119
Mounting (General)
119
Mounting the Lmu5X
119
Ignition Device
119
Terminals and Wiring
119
Testing by the Customer
120
10 Technical Data
121
Lmu
121
General
121
Electrical Connection Data
122
Cable Lengths (LMU
126
Connectors
126
Clip-In
127
Agu2.500
127
Outputs
127
Electrical Connections
127
Input
127
Agu2.51X
127
External Components
128
RAST5 Connectors
128
Mains Transformer
128
Fan with DC 24 V Motor
128
Fan with DC Motor Operating on Mains Voltage
128
11 Dimensions
129
Lmu5X
129
Lmu6X
130
AGU2.500A109 / Agu2.51Xa109
131
Agu2.500A209
132
Oci420A109
133
Oci420A209
134
Mounting Plate for Clip-In Module
135
12 Parameter List / Legend of Parameter Bit Fields LMU
136
Parameter List
136
Parameter List LMU
136
Temperatures
136
Switching Differentials
137
Controller Functions
137
Controller Times
138
Controller Coefficients
138
Pressures
138
Burner Control Fan
139
Burner Control Sequence
139
Burner Control Identification
140
Operating Data
140
MCI
140
Lpb
140
Lockout Position Storage
141
Phase Designations / Numbers
141
Legend of Parameter Bit Fields LMU
142
Controller Functions
142
Burner Control Program
145
Operating Modes
147
Lpb
147
13 Glossary of Abbreviations
148
Constants
148
Variables
148
14 Addendum: Hydraulic Diagrams BMU
149
Hydraulic Diagrams
149
Basic Diagrams
149
Pump Circuit Extensions Via AGU2.500
151
Mixing Circuit Extensions Via AGU2.500
153
Zone Extensions
156
Heat Generation Manager
162
Assignment of Hydraulic Diagrams to the Outputs of the LMU
166
Advertisement
Advertisement
Related Products
Siemens LMU54 Series
Siemens LMV51 Series
Siemens LMV52.440B1
Siemens LMV52.200A1
Siemens LMV36.520A1
Siemens LMO14 Series
Siemens LMO24 Series
Siemens LMO44.255A2
Siemens LMO14.111B2
Siemens LMO24.111B2
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL