KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 1 Safety Precautions 1.1. For Service Technicians • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 2.2.1. Suggested PbF Solder There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu), or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufacturer's specific instructions for the melting points of their products and any precautions for using their product with other materials.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 4 Technical Descriptions 4.1. US-DECT Description The frequency range of 1.92 GHz-1.93 GHz is used. Transmitting and receiving carrier between base unit and handset is same frequency. Refer to Frequency Table (P.54). 4.1.1. TDD Frame Format 5 ms 5 ms Up Link ( Handset - >...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 4.1.3. Signal Flowchart in the Radio Parts Reception A voice signal from TEL line is encoded to digital data "TXDATA" by BBIC (IC501) in a base unit. Then TXDATA goes to RF PART and it's modulated to 1.9 GHz. The RF signal is amplified and fed to a selected antenna.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 4.4. Circuit Operation (Base Unit) General Description: (BBIC, Flash Memory, EERROM) is a digital speech/signal processing system that implements all the functions of speech compression, record and playback, and memory management required in a digital telephone answering machine. The BBIC system is fully controlled by a host processor. The host processor provides activation and control of all that functions as follows.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 4.4.4. Power Supply Circuit/Reset Circuit The power supply voltage from AC adaptor is converted to VBAT (3.0V) in IC302. And +3.0V for peripherals and analog part is insulated from VBAT by Doubler of BBIC. Circuit Operation: +3.0V VBAT IC601...
Page 14
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 4.4.4.1. Charge Circuit The voltage from the AC adaptor is supplied to the charge circuits. +5.5V F301 CHARGE+ CHARGE-...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 4.4.5. Telephone Line Interface Telephone Line Interface Circuit: Function • Bell signal detection • ON/OFF hook and pulse dial circuit • Side tone circuit Bell signal detection and OFF HOOK circuit: In the idle mode, Q141 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the Tip (T) and Ring (R) leads (When the telephone rings), the AC ring voltage is transferred as follows: T ...
Page 16
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB detecting the voltage changes. If the Auto disconnect function is ON and statuses are Hold, receiving ICM, OGM transmitting, BBIC disconnects the line after detecting parallel connection is off hook. Q141 Q161 C101 Pin 18 of IC501 DCIN2 D101...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 4.4.7. Calling Line Identification (Caller ID)/Call Waiting Caller ID Function: Caller ID The caller ID is a chargeable ID which the user of a telephone circuit obtains by entering a contract with the telephone company to utilize a caller ID service. For this reason, the operation of this circuit assumes that a caller ID service contract has been entered for the circuit being used.
Page 18
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB Call Waiting Caller ID Calling Identity Delivery on Call Waiting (CIDCW) is a CLASS service that allows a customer, while off-hook on an existing call, to receive information about a calling party on a waited call. The transmission of the calling information takes place almost immediately after the customer is alerted to the new call so he/she can use this information to decide whether to take the new call.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 4.6. Circuit Operation (Handset) 4.6.1. Outline Handset consists of the following ICs as shown in Block Diagram (Handset) (P.19). • DECT BBIC (Base Band IC): IC1 - All data signals (forming/analyzing ACK or CMD signal) - All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD, RF Power Amp.)
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 5 Location of Controls and Components Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server. 6 Installation Instructions Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 8 Test Mode 8.1. Engineering Mode 8.1.1. Base Unit Important: Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit. Soft keys { OFF } (Off) Navigator key/ (Volume) key/ (Phonebook)/...
Page 25
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB Frequently Used Items (Base Unit) ex.) Items Address Default Data New Data Remarks C-ID (FSK) sensitivity 06 DD/06 DC 00/28 00/1C 00/14 When hex changes from “00/28” to “00/1C” or (3 dB up) (6 dB up) “00/14”, gain increases by 3 dB or 6 dB.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 8.1.2. Handset Important: Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit. Soft keys { OFF } (Off) Navigator key/ (Volume) key/ (Phonebook)/ CID (Caller ID) key/ REDIAL (Redial) key/...
Page 27
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB Frequently Used Items (Handset) ex.) Items Address Default Data New Data Possible Adjusted Possible Adjusted Remarks Value MAX (hex) Value MIN (hex) Battery Low 00 09 (*2) Frequency 00 07 / 00 08 70/02 00 02 ~ 00 06...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 9 Service Mode 9.1. How to Clear User Setting (Handset Only) Handset Press simultaneously until a beep sound is heard. Then single handset is initialized. 2 5 8 0 (The contents of user setting are reset to factory default)
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10 Troubleshooting Guide 10.1. Troubleshooting Flowchart FLOW CHART Not working Power ON Base Unit Check Power Not playback Playback Pre-Message Check Playback Not record Record Check Record Link No link No charge Battery Charge Check Battery Charge Check Link...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.1. Check Power 10.1.1.1. Base Unit Is the AC Adaptor inserted into AC outlet? (*1) AC Adaptor. Is output voltage of AC adaptor 5.5 V? Check Check Power Supply Circuit. Check VDDC (1.2 V): Test Point [VDDC] RSTN: Reset = "High"? Check Reset Circuit.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.2. Check Record 10.1.2.1. Base Unit A) Not record Incoming Message Check Telephone Line Interface Check Bell signal. [Bell]. Check Telephone Line Interface Does the unit catch line? [OFF HOOK]. Check Line In: Pin 16 of BBIC. Check ICM Recording in Signal Route.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.3. Check Playback 10.1.3.1. Base Unit Check VDDC (1.2 V): Test Point [VDDC] Check Power Supply Circuit. Check output of BBIC (Pin 29, 31). Check BBIC and Flash Memory. Check Speaker and its surroundings. Cross Reference: Note: Power Supply Circuit/Reset Circuit (P.13) Flash Memory is IC601.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.5. Check Link 10.1.5.1. Base Unit Does Base Unit make link with normal working Base Unit is OK. Check Handset. Handset? Is the voltage of VBAT about 3.0 V? Check around Power Supply Circuit. Is the voltage of VDDC about 1.2 V? Is the voltage of +3.0V about 3.0 V?
Page 34
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.5.2. Handset Does Handset make link with Base Unit? Handset is OK. Check Base Unit. (Correct working unit) Is the voltage of "1.8V" about 1.8 V? Adjust 1.8V voltage to 1.8 V. Check around Power Supply Circuit/Reset Circuit .
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.6. Check the RF part 10.1.6.1. Finding out the Defective part 1. Prepare Regular HS(*1) and Regular BU(*2). 2. a. Re-register regular HS (Normal mode) to base unit (to be checked). If this operation fails in some ways, the base unit is defective.
Page 36
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.6.2. RF Check Flowchart Each item (1 ~ 6) of RF Check Flowchart corresponds to Check Table for RF part (P.37). Please refer to the each item. Start Link Control Check BBIC interface parts. confirmation signal (RF Block <->BBIC on BU/HS P.C.B)
Page 37
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.6.3. Check Table for RF part Item BU (Base Unit) Check HS (Handset) Check Link Confirmation Normal 1. Register Regular HS to BU (to be 1. Register HS (to be checked) to Regular checked). HS, BU Mode [Normal Mode] 2.
Page 38
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.6.4. TEST RANGE Check Circuit block which range is defective can be found by the following check. Item BU (Base Unit) Check HS (Handset) Check Range Confirmation TX TEST 1. Register Regular HS to BU (to be checked). 1. Register HS (to be checked) to Regular BU.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.7. Registering a Handset to the Base Unit 1 Handset: {MENU} # 1 3 0 2 Base unit: Press and hold {LOCATOR} for about 5 seconds. L If all registered handsets start ringing, press {LOCATOR} again to stop, then repeat this step.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 10.1.9. Check Handset Transmission Check MIC of handset. Check handset Tx in Signal Route. Cross Reference: Signal Route (P.21) 10.1.10. Check Handset Reception Check speaker of handset. Check handset Rx in Signal Route. Cross Reference: Signal Route (P.21) Note: When checking the RF part, Refer to Check the RF part (P.35).
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 11 Disassembly and Assembly Instructions 11.1. Disassembly Instructions 11.1.1. Base Unit 11.1.1.1. KX-TGC210 Remove the 2 screws to remove the cabinet cover. Remove the solders. Solders Remove the main P.C. board.
Page 42
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 11.1.1.2. KX-TGC220 Remove the 2 screws to remove the cabinet cover. Remove the solders. Solders Remove the main P.C. board.
Page 43
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB Remove the 2 screws to remove the charge case and the operational P.C. board.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 11.1.2. Handset 2 screws Remove the 2 screws. Insert a plastic card. (Ex. Used SIM card etc.) Cabinet body between the cabinet body and the cabinet cover, then pull it along the gap to open the cabinet. Cabinet cover Likewise, open the other side of the cabinet.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 11.2. How to Replace the Handset LCD Note: The illustrations are simplified in this page. They may differ from the actual product. P. C. board Vertical Interval Tolerance Peel off the FFC (Flexible Flat Cable) from 0.2 mm the LCD, in the direction of the arrow. Take care to ensure that the foil on the P.C.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 12 Measurements and Adjustments This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in Troubleshooting Guide (P.29) 12.1. Equipment Required • Digital multi-meter (DMM): it must be able to measure voltage and current.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 12.2.2. Connections (Handset) Connect the DC Power or Battery to BATT+ and BATT-. Connect the JIG cable GND (black) to GND. Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX. (red) To Serial Port (yellow)
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 12.2.3. How to install Batch file into P.C. Insert the Batch file CD-ROM into CD-ROM drive and copy PNZZTG**** folder to your PC (example: D drive). <Example for Windows> On your computer, click [Start], select Programs Open an MS-DOS mode window.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 12.3. Adjustment Standard (Base Unit) When connecting the simulator equipment for checking, please refer to below. 12.3.1. Bottom View Frequency Counter (*1) * Send command "SFR", then the frequency output on this TP. Oscilloscope (*2) * Start Monitor +5.5V...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 12.4. Adjustment Standard (Handset) When connecting the simulator equipment for checking, please refer to below. 12.4.1. Component View ANT-Short-GND ANT-Short G R E E N RECEIVER PNLB2318Z O R A N G E T G C A 2 0 x x...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 12.5. Things to Do after Replacing IC or X'tal If repairing or replacing EEPROM and X'tal, it is necessary to download the required data such as Programming data or adjustment data, etc. in memory. The set doesn't operate if it is not executed.
Page 53
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 12.5.1.2. Handset First, operate the PC setting according to The Setting Method of JIG (P.47). Then download the appropriate data according to the following procedures. Items How to download/Required adjustment EEPROM (IC7) Adjusted parameter data is 1) Default batch file: Execute the command “default.bat”.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 13 Miscellaneous 13.1. How to Replace the Flat Package IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 13.1.3. How to Install the IC 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 14 Schematic Diagram 14.1. For Schematic Diagram 14.1.1. Base Unit (Base Unit (Main)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. Important Safety Notice: Components identified by mark have special characteristics important for safety.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 14.4. Handset (Main) Charge Current VBAT VBAT To Battery 2.5A BATT+ K0.1u SOCp 6.3V 220u BATT- J39p SOCn SHORT * When "SFR" command is executed, 13.824MHz frequency will be output. K1000p CHG+ CHG+ CP3V (3216) K0.1u To Charge Terminal K0.1u...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 15.2. Base Unit (Operation) (KX-TGC220 only) DOWN PNLB2320Z K X - T G C 2 x x H LOCATOR LED901 ERASE ANSWER1 ANSWER SKIP MSG1 REPEAT MSG3 MSG2 LED902 KX-TGC220 OPERATION BOARD (Base Unit (Component View))
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 15.3. Handset 15.3.1. Component View ANT-Short-GND ANT-Short G R E E N RECEIVER PNLB2318Z O R A N G E ANT1_TP T G C A 2 0 x x C92 C94 C61 C63 C 9 3 CP3V B L U E...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 16 Exploded View and Replacement Parts List 16.1. Cabinet and Electrical Parts (Base Unit) 16.1.1. KX-TGC210 PCB1 Ref.No. Figure 2.6 x 8mm...
(*1) This cable is fixed by welding. Refer to How to Replace the Handset LCD (P.46). (*2) The rechargeable Ni-MH battery HHR-4MY is available through sales route of Panasonic. (*3) Attach the SPACER (No. 113) to the exact location described above.
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB 16.5. Replacement Parts List 16.5.1.1.2. KX-TGC220LA 1. RTL (Retention Time Limited) Note: Safety Ref. Part No. Part Name & Description Remarks The “RTL” marking indicates that its Retention Time is PNKM1543X3 CABINET BODY PS-HB Limited. PNBC1558Z1 BUTTON, NAVIGATOR KEY...
Page 86
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks R151 D0GA104JA021 100k C863 F1G1H1R5A765 1.5p R152 ERJ2GEJ134X 130k C871 F1G1H1R5A765 1.5p R160 ERJ3GEYJ821 C872 F1G1H1R3A765 1.3p R162 ERJ3GEYJ473 C873 F1G1H2R0A765 2p...
KX-TGC210LAB/KX-TGC212LAB/KX-TGC213LAB/KX-TGC220LAB/KX-TGC222LAB/KX-TGC223LAB/KX-TGCA20LAB Safety Ref. Part No. Part Name & Description Remarks P301 PNPK3787006Z GIFT BOX 16.5.4.5. KX-TGC222LAB Safety Ref. Part No. Part Name & Description Remarks A401 PNLV226Z AC ADAPTOR (for Base Unit) A402 PQJA10075Z CORD, TELEPHONE P401 PNPK3794007Z GIFT BOX 16.5.4.6.