BATHROOM VENTILATOR OPERATION MANUAL HB21417 HB21424 Please read this Operation Manual carefully before using this machine. Warning: In order to prevent damage or accident, this machine must be installed by those qualified technicians recognized by the government. ...
Page 22
1. Important Safety Information Must use the appropriate power (220V‐240V ~/50Hz). This product is not suitable for the disabled, mental retarded or mental disorder, or those who are lack of experience and common sense (including children) unless they are under guidance. Take care of your children and do not allow them to play with this machine. In order to use this machine more properly, and reduce any danger caused by the incorrect operation, please pay attention to the following items. If the power wire is broken, please ask for the supplier and manufacturer’s replacement. Make sure the power wire places on suitable location and will not block the road. WARNING: In order to avoid overheating, do not cover the heater. The heater must not be located immediately below a socket outlet. Do not use this heater in the surroundings of a bath, a shower or a swimming pool. Product do not control room temperature, when there is no responsible person close by, please do not let those disabled stay alone in the narrow room and use the machine.
Page 23
attention to them. When the machine was installed and placed at the correct working location, there should be a person responsible for safety guidance and assistance, and to ensure the safety of the users to understand the potential risk of this machine. Children who aged from 3 to 8 only can turn on/off this machine. Please do not let the children aged from 3 to 8 to do regulation, cleaning, ...
Page 24
the room on their own, unless constant supervision is provided. Turn off the product and remove plug until the product stops working and cool down completely before clean the unit. Please do not pull out the power plug by pulling the power cord. It may cause the power cord damage or electric shock. If there is abnormal smell or noise when uses the product, please stop using and pull out the power cord immediately. Please don't put heavy unit onto the power cord or fold the power cord. It may lead to electric shock. Please don't have the wind blow to the children directly for a long time. It may influence the children's health. Please don't touch the plug by wet hands. Please don't put the wood or metal stick into the air inlet or outlet. It may lead to electric shock, or product damage. Do not use it on outdoor areas. This appliance is for household use only. Do not immerse the appliance or the electrical cord or plug in liquids. Do not use the appliance for any purpose not expressly specified in this manual. This appliance must be attended at all times when it is switched on. Do not insert any objects into the heater.
Page 25
explosive objective, away from the heater. Do not place the appliance close to children or pets. Never let children operate this appliance. Close supervision is necessary when this is used near children. Do not touch hot surface when in use. Do not share the same circuit receptacle with others appliances, otherwise may have burn hazard. Do not use extension cord or exchangeable plug. Unplug heater if it fails to operate properly and inform customer service center. Dispose of packaging properly. The heater only for personal use, not for heating any liquids or other danger things. Persons (including children) with reduced physical, sensory or mental capabilities, or any individual lacking experience and knowledge should be supervised or given instruction by a person responsible for their safety when they using this appliance. Unless being supervised, the above persons (included children) can't use this appliance. ‐ 4 ‐ ...
Page 26
ns 2. Instal lation Pr recaution This p roduct sho ould be ins talled in th he place wh here can b ear the we eight of thi s goods. Incorr rect installa ation may c cause nois e, empath y. Please a assembly p roperly. In ord der not to cause the dew flow wing back f from ...
Page 27
【Names of the device and functions】 Unit: mm 1. Machine Front Side Bottom Remote Control 1. Pre‐Filter, Carbon Filter 2. Front Panel 3. Display Panel 4. Air Outlet 5. Stainless Steel Housing 6. Metal Louver 7. Air Outlet Joint (Applicable to Window type installation) (Applicable to Ceiling/Wall type installation) ‐ 6 ‐ ...
Page 28
2. Remote LCD Display Battery Replacement sense Ionizer Time Display Air volume Hi/Mid/Lo Swing Function Display Remark: The remote control of HB21417 and HB21424 is the same except the model number difference. ‐ 7 ‐ ...
Over 5cm 【Installation Method】 Main Body Air outlet joint A. Ceiling fixed frame method Exhaust pipe Downdip 1°-2° Over 50cm to the wall Self-tapping Inspection opening screw(2 pieces) Installation reference picture: Front Panel Screw hole 1,2,3,4,5,6,7,8 for ceiling joist installation Screw hole A,B,C,D for suspended ceiling installation Screw hole 1,2,3,4,5,6,7,8 for window installation Install the Fixed Frame to the ceiling Make the fixed frame. Please use materials that can bear 8.5kg to fix the surrounding part. The fixed frame should use sticks of 30*25mm. Size of the inner part of the frame: 380*272mm. ...
Page 30
【Instal lation M Method】 B. Ceilin ng Type M Method Follo ow the belo ow diagram to fix the m main body w with the M8 8 nut and th he suspende ers (sug ggested to u use M8 susp penders and d need to be e purchased d separately y). M8 Suspender M8 Nut Lock Washer Washer Lock Washer M8 Nut Ceiling suspension Bracket ...
【Installation Method】 C. Wall mount type method 1. Applicable to the bathroom without ceiling. 2. Firstly set the support stick transverse stability to the wall, then embed the main body on the support. 3. Set the exhaust pipe (4“ ( 100mm) ) to the glass window. Fix the exhaust pipe to the air outlet joint with tape or metal clamp. 4. Applicable size of the main body: 420x320mm *need to reserve 200 mm on the right side to install the exhaust pipe and air outlet joint. Thickness of the main body:216mm 5. The minimum distance between the surrounding structures should be 50cm。 200mm 【Air Exhaust】 Please avoid the following situations when installing the exhaust pipe. 1. Over bending. 2. Bending too much. 3. The bend of the pipe comes too close to the main body. 4. The bend shrinks. ‐ 10 ‐ ...
Page 32
【Installation Method】 Wall Window Type Window Stainless Steel Housing Size Front Panel Front Panel (HxW): 320x420 mm Machine Body* (HxW): 270x372 mm * Exclude the front panel Window Window Cut Out (HxW): 275x377 mm 1. Install at the place of the aluminum framed window or replace the exhaust fan in the bathroom. 2. Fix the stainless steel housing to the frame of the aluminum window (must use the waterproof glue for the waterproof). ...
Page 33
【Installation of the Remote Control】 1. Take out the remote control from the holder. 2. Install the remote control to suitable place. Check the main body can receive signal from the remote control installation location or take out the remote control to check the receiver sensitivity. The installation location cannot be toward the direct spraying area of the shower. 3. Fix the remote control holder to the designed place and make marks according to the arrows. 4. Dig holes according to the mark, fill the holes with 2 plastic plugs, and fix the holder with screws.
Page 34
【Instructions】 Operation Mode Time Function Application Default Setting Ventilation Fan Circulation Fan PTC* (Max.) 1. Quick Heat Off High Speed On 2 hrs 12 hrs Heat (Hi) Off High Speed 2 hrs 12 hrs On Warm Air Heat (Mid) Off Medium Speed 2 hrs 12 hrs On Heat (Lo) Off Low Speed 2 hrs 12 hrs On ...
【Function Descriptions】 1) Display :Power Indicator – Blue indicator light on when connected to power supply :Air Quality Indicator – Red indicator light means “Poor”, Orange indicator light means “Fair”, Green indicator light means “Good” :Malfunction Indicator – Red indicator light on when the machine is failure 2) HEAT Function – Quick Heat Press the “Quick Heat” button, the LCD displays the “Quick Heat” icon, air volume will run at “Hi “mode. Timer: the default time is 2 hrs. By pressing “Timer “up or down button to select time duration. The time can be set from 5 mins to 12 hrs. The time counter will be displayed at the LCD. The time selected will be recorded in memory when it is off, and will resume in your next usage. Stop: when press the “Stop “button or pre‐set time runs over, the LCD “Quick Heat ...
Page 36
3) VENT Function ‐ Hi / Mid / Lo Press the “Vent” button, the LCD displays “Vent” icon, air volume will run at “Hi” mode. Press the button again to select “Hi”, “Mid” or “Lo” mode. Timer: the default time is 2 hrs. By pressing “Timer” up or down button to select time duration. The time can be set from 5 mins to 24 hrs. The time counter will be displayed on the LCD. The time selected will be recorded in memory when it is off, and will resume in your next usage. Under the mode, the inter‐change of the air volume between “Hi”, “Mid” or “Lo” will not affect the time counting. Stop: when press the “Stop” button or the pre‐set time runs over, the LCD “Vent” and the time display would disappear, and the machine will stop automatically. 4) DRY Function ‐ Hi / Mid / Lo Press the “Dry” button, the LCD displays “Dry” icon, the air volume will run at “Hi” ...
Page 37
6)6 Sense De‐odor Function Press “6 Sense” button, the LCD displays “ ” icon. In 6 Sense mode, the machine will automatically detect the odor of the bathroom and run the de‐odor function. The air quality light will indicate the odor level, Red indicator light means “Poor”, the machine will run at “Hi” mode; Orange indicator light means “Fair”, and the machine will run at “Mid” mode; Green indicator light means “Good”, and the machine will run at “Lo” mode.
Page 38
Swing Function – Manual (Left / Right) Left and right louver function to provide selection of wide airflow distribution of up to 120 degree, or concentrated airflow. Diffused Airflow Concentrated Airflow Ionizer Function When the circulation fan motor is running, press the “Ionizer” button, the LCD will display “ ” icon. Ionizer function is not valid under the modes of “Vent”, 24H Vent”, “Delay Vent” and “6 Sense”. Stop: when Ionizer is running, press the “Ionizer” button, Ionizer will stop, and the LCD “ ” icon would disappear. Press the “Ionizer” button again, Ionizer will turn on again and the LCD will display “ ” icon as well. ‐ 17 ‐ ...
Page 39
【Maintenance and Safety Items】 Maintenance and cleaning: ● Please do turn off the power before maintenance work. Front Panel 1. Front panel cleaning: Filter ○ Please use the soft rag to clean the dirty place of the front panel. ○ Put a clean rag in the warm water dissolved with neutral detergent, and then use the rag to wipe the front panel. Use another rag to wipe the cover. The surface shall have no detergent residues. 2. Filter Cleaning: A. Pre‐Filter ○ Use a rechargeable handheld vacuum cleaner to remove dust from the filter or wash ...
Page 40
Safety Items: Do not put your hands into the machine when running, to avoid from injury or burn by the heater. Do not spray water into the main body, which may damage the motor, or cause electric shock by the electricity leakage. In order to avoid from any accident or injury, if any of the following symptoms and abnormal situation occur, please switch off the electricity and ask qualified electrical engineering contractor for repair or check. (Self repair by user is strictly prohibited to avoid danger).
Fix the suspension Lock washer Φ 8 bracket Ceiling suspension ‐ 4 bracket Applicable to 5. Air Outlet Joint Ceiling/Wall type ‐ ‐ 1 installation 【Product Specification】 Model No. HB21417 HB21424 Voltage (V) 220‐240V~ Frequency (Hz) 50Hz Power (W) 1700W 2450W Product Size 320 x 420 x 216 (H x W x D) mm Product Size (excl. panel) 270 x 372 (H x W) mm Net Weight (kg) 8.5 ...