Safety Precautions This installation manual describes how to install the PIM . For installation of other optional accessories, refer to the appropriate installation manual . WARNING Hazards or unsafe practices that may result in severe personal injury or death. CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage.
Accessories Make sure you have each item . Supplied items may vary depending on your country or service provider . The type and quantity may differ depending on the specifications . Installation Item Adapter Power cable M4x16 Screw Cable tie manual Quantity Shape...
Viewing the Parts Main Parts PIM Exterior lCD Display Shows current time and consumption by channel . Various menus will be displayed depending on button input . lCD Operation button There are 4 buttons [Menu, ▼(Down), ▲(Up), Set] and you can access, move and check the menu . lED Indicator Checks the status using 14 LEDs such as Power, COM1 TX/RX, Signal, COM2 TX/RX and Check .
Page 6
Viewing the Parts PIM Cable Connection Part Pulse input terminal Pulse input terminal RS485 communication terminal (Channel 1~4) (Channel 5~8) (COM1, COM2) Cable groove Power terminal Reset button Name Description Terminal that the pulse from Meter is inputted Pulse input terminal (Channel1~Channel8) (CH1~CH8) ❇...
Page 7
PIM Interior LED Display board 20-pin cable Main board 40-pin cable Sub board Product Dimensions 64 . 8 (Unit : mm) English-7...
PIM System Architecture Pulse input ROOM 0 ROOM 1 ROOM 2 Meter Outdoor Unit Meter (max . 8 units) f Maximum 8 PIM units can be connected to DMS . f Maximum 8 meter(Power/Gas/Water) can be connected to PIM . English-8...
Installing the PIM Installing the PIM on the Wall 1 . Separate the installation plate on the rear side of PIM . 2 . Fix the installation plate on the wall using 4 screws . 3 . Hang the PIM on the groove which is on the top of the installation plate . Installation plate 4 .
Page 10
Installing the PIM Connecting a Meter, PIM and DMS Connecting a Meter and PIM 1 . Unfasten the 2 screws on the bottom of the PIM front cover . Hold the bottom 2 sides of the PIM and push downwards to slide open the cover . 2 .
Page 11
Connectable Meter with PIM Meter without Separate External Output f If the pulse constant(Wh/Pulse or m /Pulse or L/Pulse) value is an integer, connection is possible . e . g . Pulses per kWh : 1,000 converted to 1Wh/Pulse, Connection is possible! e .
Page 12
Installing the PIM Connecting PIM to DMS 1 . Connect ‘COM1’ terminal of PIM and DMS terminal block with communication cable . - Pay special attention about the polarity when connecting RS485 communication . (A of PIM ↔ A of DMS, B of PIM ↔ B of DMS) Connect Connect communication...
Page 13
f If PIM is connected to DMS, PIM setting through DMS web is possible . English-13...
Page 14
Installing the PIM Installing more than 2 PIM Units to 1 DMS 1 . Unfasten the 2 screws on the top of the PIM . Hold the top 2 sides of the PIM and pull it the cover upwards to open the cover . 2 .
Setting the PIM Setting the PIM(Mandatory) It is mandatory when you connect Meter and PIM . Setting the Password 2.1Password Set your P/W Password Set : : : Main menu → 2 . Configuration → 2 . 1 Password . f Default : 0000 f For the further information, refer to page 20 .
PIM Menu Description Menu Configuration Normal Display 1. Monitoring 1.1 Address 1.2 Option S/W Current Time 1.3 Micom Ver. CH1: 00000.0kWh 1.4 DB Code CH2: 00000.0kWh 2. Configuration 2.1 Password CH8: 00000.0kWh 2.2 Meter Type Displayed repeatedly 2.3 Pulse Rate 2.4 Date&Time 2.5 Channel Use 2.6 Value Set...
Page 17
Normal Display 1 . When the power is connected, current PIM address and software version will be displayed . - Example display: PIM address 58 30 FF Software version DB91-01128A - “Address:58 30 FF” is an example . It is subject to change according to the setting . Device Info.
Page 18
PIM Menu Description Monitoring Menu Address 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘1 . M onitoring’ by pressing the [Set] button . Main Menu 1.Monitoring 2 . To check the Address, press the [Set] button when ‘1 . 1 Address’ appears . 1.Monitoring 1.1 Address 1.1 Address...
Page 19
Micom Version 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘1 . M onitoring’ by pressing the [Set] button . Main Menu 1.Monitoring 2 . To check the Micom Version, press the [Set] button when ‘1 . 3 Micom Ver . ’ appears . 1.Monitoring 1.3 Micom Ver.
Page 20
PIM Menu Description Configuration menu Setting the Password f You should enter the password to use Configuration menu . Password Set 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘2 . C onfiguration’ by pressing the [], [] buttons, and press the [Set] button .
Page 21
Password Reset 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘2 . C onfiguration’ by pressing the [], [] buttons, and press [Set] button . Main Menu 2.Configuration 2 . Enter the password using the [], [] buttons and press the [Set] button . - The default password is ‘0000’...
Page 22
PIM Menu Description Setting the Meter Type f You can set the meter type . 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘2 . C onfiguration’ by pressing the [], [] buttons, and press the [Set] button . Main Menu 2.Configuration 2 .
Page 23
Setting the Pulse Rate f You can set the pulse constant (Wh/Pulse or m /Pulse or L/Pulse) value of the meter connected to each channel . 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘2 . C onfiguration’ by pressing the [], [] buttons, and press the [Set] button .
Page 24
PIM Menu Description Setting the Date and Time Date setting 1 . Access to main menu by pressing [Menu] button from the normal display . Then select ‘2 . C onfiguration’ by pressing the [], [] buttons, and press [Set] button . Main Menu 2.Configuration 2 .
Page 25
Time setting 1 . Access to main menu by pressing [Menu] button from the normal display . Then select ‘2 . C onfiguration’ by pressing the [], [] buttons, and press [Set] button . Main Menu 2.Configuration 2 . Enter the password using the [], [] buttons and press the [Set] button . - The default password is ‘0000’...
Page 26
PIM Menu Description Setting the Enable/Disable Status of Channel f Enable/Disable the 8 pulse input channels . 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘2 . C onfiguration’ by pressing [], [] buttons, and press the [Set] button .
Page 27
Setting the Initial Value f You can set the initial value for each channel . 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘2 . C onfiguration’ by pressing the [], [] buttons, and press the [Set] button . Main Menu Enter your P/W 2.Configuration...
Page 28
PIM Menu Description Initializing the usage value for each channel 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘2 . C onfiguration’ by pressing the [], [] buttons, and press the [Set] button . Main Menu 2.Configuration 2 .
Page 29
Check Menu Pulse Input Status Check f You can check the status of pulse which is input to each channel . 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘3 . Check’ by pressing the [], [] buttons, and press [Set] button .
Page 30
PIM Menu Description Check the RS485 Circuit of PIM itself for Test or Service f You can check if the RS485 circuit is normal when you have doubt the main board . f Before checking, connect COM1 and COM2 terminal with wire as you see the right figure . 1 .
Page 31
Checking the Pulse Width Setting Error f It checks if the pulse width setting for each channel and the pulse width of actually connected Meter are same or not . 1 . Access to main menu by pressing the [Menu] button from the normal display . Then select ‘3 . Check’ by pressing the [], [] buttons, and press the [Set] button .