Page 2
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 1 Safety Precautions 1.1. For Service Technicians • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work. 1.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 2.2.1. Suggested PbF Solder There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu), or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufacturer's specific instructions for the melting points of their products and any precautions for using their product with other materials.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 3 Specifications Handset Base Unit Charger Power Supply AC Adaptor Rechargeable Ni-MH battery AC Adaptor (KX-TG3711/3712: PNLV226BX0Z, (2 x 1.2 V, 550 mAh) (KX-TG3711/3712: PNLV226BX0Z, 100-240 V AC, KX-TG3719: 100-240 V AC, KX-TG3719: PNLV226EZ, 220-240 V AC, 50/60 Hz) PNLV226EZ, 220-240 V AC, 50/60 Hz) Receiving/Transmitting Frequency 91 channels within 2.4 GHz - 2.48 GHz...
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4 Technical Descriptions 4.1. FHSS Description 4.1.1. Frequency The frequency range of 2.4 GHz-2.48 GHz is used. Transmitting and receiving channel between base unit and handset is same frequency. 4.1.2. FHSS (Frequency Hopping Spread Spectrum) This telephone is using an IC chip which has similar specification to WDCT (World Digital Cordless Telephone) and is the telephone system that can use multiple portable unit simultaneously.
Page 8
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.1.2.1. TDD Frame Format 5 ms 5 ms Up Link ( Handset - > Base Unit ) Down Link ( Base Unit - > Handset ) DATA rate : 576 Mbps 833 µs 4.1.2.2. TDMA system This system is the cycles of 10 ms, and has 6 duplex paths, but maximum duplex communication path is 5 because of dummy bearer use.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.5. Circuit Operation (Base Unit) General Description: (BBIC, EEPROM) is a digital speech/signal processing system that implements all the functions of speech compression and memory management required in a digital telephone. The BBIC system is fully controlled by a host processor. The host processor provides activation and control of all that functions as follows.
Page 13
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.5.4. Power Supply Circuit/Reset Circuit The power supply voltage from AC adaptor is converted to VBAT (3.0V) in IC302. And +3.0V for peripherals and analog part is insulated from VBAT by Doubler of BBIC. Circuit Operation: VDD4 +5.5V +3.0V VDD3 IC502 IC501...
Page 14
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.5.4.1. Charge Circuit The voltage from the AC adaptor is supplied to the charge circuits. +5.5V F301 R373 CHARGE+ C351 CHARGE-...
Page 15
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.5.5. Telephone Line Interface Telephone Line Interface Circuit: Function • Bell signal detection • ON/OFF hook and pulse dial circuit • Side tone circuit Bell (RINGING) signal detection and OFF HOOK circuit: In the idle mode, Q141 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the Tip (T) and Ring (R) leads (When the telephone rings), the AC ring voltage is transferred as follows: L1T→L101→C105→R105→R110→R111→R112→BBIC pin18(RINGING) When the CPU (BBIC) detects a ring signal, Q141 turns on, thus providing an off-hook condition (active DC current flow through...
Page 16
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.5.6. Parallel Connection Detect Circuit/Auto Disconnect Circuit Function: In order to disable call waiting and stutter tone functions when using telephones connected in parallel, it is necessary to have a circuit that judges whether a telephone connected in parallel is in use or not. This circuit determines whether the telephone connected in parallel is on hook or off hook by detecting changes in the T/R voltage.
Page 17
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.5.7. Calling Line Identification (Caller ID)/Call Waiting Caller ID Function: The caller ID is a chargeable ID which the user of a telephone circuit obtains by entering a contract with the telephone company to utilize a caller ID service. For this reason, the operation of this circuit assumes that a caller ID service contract has been entered for the circuit being used.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.8. Circuit Operation (Handset) 4.8.1. Outline Handset consists of the following ICs as shown in Block Diagram (Handset) (P.18). • DECT BBIC (Base Band IC): IC1 - All data signals (forming/analyzing ACK or CMD signal) - All interfaces (ex: Key, Detector Circuit, Charge, EEPROM, LCD) •...
Page 21
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.8.3. Charge Circuit Circuit Operation: When charging the handset on the Base Unit, the charge current is as follows; DCP+(5.5 V) → F301 → R371 → R372 → D362 → CHARGE+(Base) → CHARGE+(Handset) → → Q4 → F1 → BATTERY+...
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 4.9. Behavior of Electric Power Failure In case that the power from AC adaptor is lost and lose radio waves, BBIC (IC1) turns Q11 and Q10 ON since handset presumes that base unit's power is failed. Base unit detects that power voltage of AC adaptor +5.5V is OFF at IC351, then turns Q351 ON. It's possible to use the units during the power failure, supplying power to VBAT of base unit from battery of handset through IC6, CHG terminal and Q351.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 5 Location of Controls and Components Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server. 6 Installation Instructions Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server. 7 Operating Instructions Refer to the Operating Instructions.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 8 Test Mode 8.1. Engineering Mode 8.1.1. Base Unit Important: Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit. soft keys {OFF} Navigator key ? (Volume) key {FLASH} {CALL WAIT} Dial keypad H/S LCD H/S key operation...
Page 26
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX Set Addr.: 7). Press , a long confirmation beep New Data will be heard. CLEAR 8). Press {OFF} to return to standby mode. Set Addr.: After that, turn the base unit power off and then power on. _ _ _ _ BACK or {>} at "...
Page 27
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 8.1.2. Handset Important: Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit. soft keys {OFF} Navigator key ? (Volume) key {FLASH} {CALL WAIT} Dial keypad H/S key operation H/S LCD 1).
Page 28
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX Frequently Used Items (Handset) ex.) Items Address Default Data New Data Possible Adjusted Possible Adjusted Remarks Value MAX (hex) Value MIN (hex) Battery Low 00 09 (*2) Frequency 00 07/00 08 70/02 00 02~00 06 Given value Note: (*1) When you enter the address or New Data, please refer to the table below. Desired Number (hex.) Input Keys Desired Number (hex.)
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 8.2. Copying Phonebook Items when Repairing You can copy the handset phonebook to another (compatible Panasonic) handset. This will help to save the original phonebook data which the customer has registered. Refer to the following procedures. Phonebook data is stored in a handset.
Page 30
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX Case 3: A handset has a defect. (Radio transmission is functioning.) Service center has a normal HS (B). HS (A) HS (A) HS (B) BS (A) BS (A) 1. Cancel HS (A). 2. Register HS (B) as a handset no. 1. 3.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 9 Service Mode 9.1. How to Clear User Setting Units are reset to the Factory settings by this operation (Erase stored Phone numbers, Caller list and etc.) Note: • Some menus are not reset. Refer to Operating Instructions (P.24). •...
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 10 Troubleshooting Guide 10.1. Troubleshooting Flowchart FLOW CHART Not working Power ON Base Unit Check Power Link No link No charge Battery Charge Check Battery Charge Check Link Range Check the RF part No voice Handset Voice Transmission Check Handset Transmission No voice Handset Voice Reception Check Handset Reception...
Page 33
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 10.1.1. Check Power 10.1.1.1. Base Unit Is the AC Adaptor inserted into AC outlet? (*1) AC Adaptor. Is output voltage of AC adaptor 5.5 V? Check Check Power Supply Circuit. Check VDD1(1.8V) :Test point (VDD1) RSTN: Reset = "High"? Check Reset Circuit.
Page 34
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 10.1.2. Check Battery Charge 10.1.2.1. Base Unit Plug in the AC Power source. Charge Handset on Base Unit. Check Charge Circuit of Base Unit. Is the voltage of two charge contacts about 3 V or more? Check Handset. Check Charge Contacts at Base Unit from mechanical point of view.
Page 35
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 10.1.3. Check Link 10.1.3.1. Base Unit Does Base Unit make link with normal working Base Unit is OK. Check Handset. Handset? Is the voltage of VDD3 about 3.0V? Check around Power Supply Circuit. Is the voltage of VDD1 about 1.8V? Does the RF clock (CLK) oscillate at 10.368 MHz in Check around X501 and RF module and adjust Base Unit Test Mode?
Page 36
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 10.1.3.2. Handset Does Handset make link with Base Unit? Handset is OK. Check Base Unit. (Correct working unit) Is the voltage of TP BAT about 2.2~2.8 V? Check the batteries. Check around Power Supply Circuit/Reset Circuit. Is the voltage of TP 1.8V about 1.8 V? Is the voltage of TP CP3.0 about 3.0 V? Adjust +3.0V Vottage to 3.0V Does the RF clock (CLK) oscillate: 10.368 MHz...
Page 37
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 10.1.4. Check the RF part 10.1.4.1. Finding out the Defective part 1. Prepare Regular HS(*1) and Regular BU(*2). 2. a. Re-register regular HS (Normal mode) to base unit (to be checked). If this operation fails in some ways, the base unit is defective. b.
Page 38
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 10.1.4.2. RF Check Flowchart Please refer to the each item. Start Link Control Check BBIC interface parts. confirmation signal (RF Block <->BBIC on BU/HS P.C.B) Normal confirmation X'tal Frequency Adjust X'tal Frequency. (*1) confirmation TX confirmation Check TX Block. Range confirmation TEST RANGE Check.
Page 39
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 10.1.5. Registering a Handset to the Base Unit 1 Handset: {MENU} i # 1 3 0 2 Base unit: Press and hold {LOCATOR} for about 5 seconds. (No registration tone) The next step must be completed within 90 seconds. 3 Handset: Press {OK}, then wait until a long beep sounds.
Page 40
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 10.1.8. Check Handset Transmission Check MIC of handset. Check handset Tx in Signal Route. Cross Reference: Signal Route (P.23) 10.1.9. Check Handset Reception Check speaker of handset. Check handset Rx in Signal Route. Cross Reference: Signal Route (P.23) Note: When checking the RF part, Refer to Check the RF part (P.37).
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 11 Disassembly and Assembly Instructions 11.1. Disassembly Instructions 11.1.1. Base Unit Remove the 4 screws to remove the cabinet cover. Remove the tape and solders. Cabinet cover Tape and Solders Remove the screw to remove the jack holder. Jack holder...
Page 42
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX Remove the screw to remove the main P.C. board.
Page 43
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 11.1.2. Handset 2 screws Remove the 2 screws. Insert a plastic card. (Ex. Used SIM card etc.) Cabinet body between the cabinet body and the cabinet cover, then pull it along the gap to open the cabinet. Cabinet cover Likewise, open the other side of the cabinet.
Page 44
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 11.1.3. Charger Unit 2 charge terminals...
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 11.2. How to Replace the Handset LCD Note: The illustrations are simplified in this page. They may differ from the actual product. P. C. board Vertical Interval Tolerance Peel off the FFC (Flexible Flat Cable) from 0.2 mm the LCD, in the direction of the arrow. Take care to ensure that the foil on the P.C.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12 Measurements and Adjustments This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in Troubleshooting Guide (P.32) 12.1. Equipment Required • Digital multi-meter (DMM): it must be able to measure voltage and current. •...
Page 47
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.2.2. Connections (Handset) Connect the DC Power or Battery to BATT+ and BATT-. Connect the JIG cable GND (black) to GND. Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX. URX (red) To Serial Port UTX (yellow) (com port 1*) GND (black)
Page 48
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.2.3. How to install Batch file into P.C. Insert the Batch file CD-ROM into CD-ROM drive and copy PNZZTG**** folder to your PC (example: D drive). <Example for Windows> On your computer, click [Start], select Programs Open an MS-DOS mode window. (All Programs for Windows XP/Windows Server 2003), then click MS-DOS Prompt.
Page 49
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.2.4. Commands See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00” to “FF” is read out. readid Read ID (RFPI) Type “readid”, and the registered ID is read out.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.3. Adjustment of Base Unit When IC501 (BBIC) or IC611 (EEPROM) is exchanged, the Bandgap adjustment and the Frequency adjustment are necessary. When X501 (X'tal) is exchanged, the Frequency adjustment is necessary. Procedure: 1. Open a window of MS-DOS mode from the start-up menu. 2.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.4. Adjustment of Handset When IC5(BBIC) or IC3 (EEPROM) is exchanged, the Bandgap adjustment and the Frequency adjustment are necessary. When X1 (X'tal) is exchanged, the Frequency adjustment is necessary. Procedure: 1. Open a window of MS-DOS mode from the start-up menu. 2.
Page 52
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX Adjustment of backup power supply: Supply a handset with 2.6V power, then connect serial JIG cables. The power should be DC 2.6V 0.02V between BAT and GND. Run the batch file "DAVchk_TGA371_381.bat", which is found in the CD-ROM. Read and confirm the display data. If successful, "OK" is displayed as below. Press any key, and verify backup power supply.
Page 53
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX Verifying backup power supply: Run the batch file "DAVread_only_TGA371_381.bat", which is found in the CD-ROM. As shown in the picture below, the readout of four times detection are displayed. The average should be within the range of 00 to 06 hex. Press any key to continue.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.6. Adjustment Standard (Charger Unit) When connecting the simulator equipment for checking, please refer to below. 12.6.1. Bottom View Digital Volt Meter /2 W 3.0A DC POWER DC 5.5 V...
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.8. Things to Do after Replacing IC or X'tal If repairing or replacing EEPROM or X'tal, it is necessary to download the required data such as Programming data or adjustment data, etc. in memory. The set doesn't operate if it is not executed. 12.8.1.
Page 58
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.8.1.2. Handset First, operate the PC setting according to The Setting Method of JIG (P.46). Then download the appropriate data according to the following procedures. Items How to download/Required adjustment FLASH (IC4) Program D/L 1) Make sure to connect the JIG cable, then disconnect the DC Power in order to download the data.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.9. How to Check the Handset Receiver 1. Prepare the digital voltmeter, and set the selector knob to ohm meter. 2. Put the probes at the speaker terminals as shown below. SPEAKER: Is the value between (+) terminal and (–) terminal about 8 ? RECEIVER: Is the value between (+) terminal and (–) terminal about 34 ?
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 12.10. Frequency Table (MHz) Channel Center Frequency (MHz) RX Local Frequency (MHz) 65 (41H) 2457.216 2458.08 Channel Center Frequency (MHz) RX Local Frequency (MHz) 66 (42H) 2458.08 2458.944 2 (02H) 2402.784 2403.648 67 (43H) 2458.944 2459.808 3 (03H) 2403.648 2404.512 68 (44H) 2459.808...
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 13 Miscellaneous 13.1. How to Replace the LLP (Leadless Leadframe Package) IC Note: This description is only applied on the model with Shield case. 13.1.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700 °F ± 20 °F (370 °C ± 10 °C) Note: We recommend a 30 to 40 Watt soldering iron.
Page 62
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 13.1.4. How to Install the IC 1. Place the solder a little on the land where the radiation GND pad on IC bottom is to be attached. Soldering Iron Land Solder P.C.Board 2. Place the solder a little on the land where IC pins are to be attached, then place the IC. Note: •...
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 13.2. How to Replace the Flat Package IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins. 13.2.1.
Page 64
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 13.2.3. How to Install the IC 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC. 3.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 13.3. How to Replace the Shield Case 13.3.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700°F ± 20°F (370°C ± 10°C) Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less experience could overheat and damage the PCB foil.
Page 66
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 13.3.4. How to Install the Shield Case Note: • If you don’t have special tools (ex. Hot air disordering tool), conduct the following operations. • Shield case’s No. : PNMC1032Z, PNMC1033Z 1. Put the shield case. 2. Solder the surroundings.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 14 Schematic Diagram 14.1. For Schematic Diagram 14.1.1. Base Unit (Schematic Diagram (Base Unit_Main)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. Important Safety Notice: Components identified by mark have special characteristics important for safety.
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 16 Exploded View and Replacement Parts List 16.1. Cabinet and Electrical Parts (Base Unit) 11 (*1) (CUSHION/LCD) Push the lead wire toward the arrow after it puts a seal. Do not process a lead wire on jack holder. PCB1 Ref.No.
(*1) This cable is fixed by welding. Refer to How to Replace the Handset LCD (P.45). (*2) The rechargeable Ni-MH battery HHR-4MRT is available through sales route of Panasonic. (*3) Attach the SPACER (No. 115) to the exact location described above.
1. RTL (Retention Time Limited) PNJT1064Z CHARGE TERMINAL Note: PNBC1360Z1 BUTTON, LOCATOR (for ABS-HB KX-TG3711BXB)(for KX- The “RTL” marking indicates that its Retention Time is TG3712BXB)(for KX- Limited. TG3719BXB) When production is discontinued, this item will PNBC1360Y5 BUTTON, LOCATOR (for...
Page 87
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks (VARISTOR) R892 ERJ2GEJ221 SA101 J0LF00000048 VARISTOR (SURGE (CAPACITORS) ABSORBER) C101 ECUV2H681KB 680p (RESISTORS) C102 ECUV2H681KB 680p R101 PQ4R10XJ475 4.7M C103 ECUV1C103KBV 0.01 R102 PQ4R10XJ475 4.7M...
Page 88
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks C859 ECUE1H100DCQ 10p C3FBLY000125 IC (*1) C860 F1G1H3R3A798 3.3p (TRANSISTORS) C861 F1G1H2R0A798 2p B1ADGE000012 TRANSISTOR(SI) (OTHERS) B1ABGE000011 TRANSISTOR(SI) PNMC1033Z CASE, MAGNETIC SHIELD B1ADCF000040 TRANSISTOR(SI) (*2) B1ADCF000040 TRANSISTOR(SI)
Page 89
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks ERJ2GEJ331 C810 F1G1HR60A798 0.6p ERJ3GEYJ332 3.3k C811 F1G1H100A722 10p ERJ2GEJ103 C812 F1G1H1R6A798 1.6p ERJ2GEJ102 C813 F1G1HR60A798 0.6p ERJ2GEJ101 C814 F1G1H100A722 10p ERJ2GEJ103 C820 F1G1H3R9A798 3.9p...
Page 90
KX-TG3711BX/KX-TG3712BX/KX-TG3719BX/KX-TGA371BX 16.5.4. Accessories Note: (*1) You can download and refer to the Operating Instructions (Instruction book) on TSN Server. Safety Ref. Part No. Part Name & Description Remarks PNLV226BX0Z AC ADAPTOR (for KX- TG3711BXB)(for KX- TG3712BXB) PNLV226EZ AC ADAPTOR (for KX- TG3719BXB) PQJA10075Z CORD, TELEPHONE...