OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING:
Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
product. Equipment damage, injury to personnel or death could result from improper installation.
Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment,
injury or death to personnel that may result from improper installation or operation of this product.
WARNING:
HAZARD OF SHOCK OR FIRE
Always use recommended fuse, circuit breaker and wire size.
Motors used with this product are "Ignition Protected". They are not however,
explosion-proof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.
DO NOT run continuously for more than 30 seconds.
WARNING:
HAZARD OF FLOODING - Always shut off seacock(s) before leaving the boat unattended.
Double clamp all below waterline hose fittings and check frequently for integrity.
Pressurized Fresh
Water Model
Model and Serial#:
Please have this available if support is needed.
L365v0922jlc
SeaEra QC Toilet
Raw Water Model
(Remote Pump)
Description:
SeaEra toilet is available in 12V or 24V DC. Bowls are
available in two models: standard and household. Fresh
water model utilizes onboard fresh water, the raw water
model utilizes a remote pump installed between raw water
source and bowl. Sea/Fresh models can switch between
fresh and raw water source.
Three different control options are available:
1.
Smart toilet control (STC): provides timed opera-
tion and independent control of water and discharge
2.
Multifunction Flush Panel (221600): provides
momentary operation and independent momentary
control of water and discharge
3.
Momentary Flush Switch (PRS): providing only
the ability to flush with no independent control of
water or discharge.
Link to online
Warranty
Registration
1-800-352-5630
1
www.raritaneng.com

Advertisement

loading

Summary of Contents for Raritan SeaEra 162

  • Page 1 FOLLOWED DURING BOTH INSTALLATION AND OPERATION. WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product. Equipment damage, injury to personnel or death could result from improper installation. Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment, injury or death to personnel that may result from improper installation or operation of this product.
  • Page 2 Serious injury or death could occur. Children can drown in water retained in the bowl. Seat and/or lid could close and strike child. Always replace circuit breaker and fuses with same rating . Use Raritan parts to maintain ignition pro- tection requirements. • No special toilet paper is required.
  • Page 3 Remote Intake Pump Model CONTROL SWITCH OPERATION: Parts Required: • 3/4" (19 mm.) I.D. intake hose approximately 3 Refer to manual enclosed in control switch. feet (1 m.) long. • 1" (25 mm.) or 1 1/2" (38 mm.) I.D. discharge hose approximately 3 feet (1 m.) long. Winterizing: • Two buckets •...
  • Page 4 Pressurized Freshwater or Remote Sea Water Model 4 1 16 [104] 4 1 8 [105] SEE NOTE 1 [152] 1 5 8 [42] 3 5 16 6 3 16 [84] [157] 6 5 8 [168] BOWL TYPE INTAKE 14 1/2 26 1/2 10 3/8 17 1/4...
  • Page 5 Plumbing Maximum suction of Intake pump 4 Ft. (1.2m) from Intake Pump. (Maximum height above waterline) 6 Ft. (1.8m) from base of toilet. Maximum height of discharge vented loop Minimum flow rate of 3.5 gpm (13.25 Pressurized water source requirements liters) at 10psi (70 K pa) shutoff pressure of 5 psi (34.5 kPa).
  • Page 6 Parts Included Mounting In-Line Strainer (Raw Water Models Only) All Complete Toilets Toilet Bowl Make sure strainer bowl is tight. Seat and Cover Locate strainer where it will be accessible. Lower Base Assembly Mark and drill mounting holes. Motor Cover NOTE: Hole size will depend on type of bolts/screws used 1 1/2 (38mm) 90° Discharge fitting (1/4”...
  • Page 7 1” hose adapter into the 90° fitting. Use non hardening thread sealant. FIG 7 IMPORTANT: Do not overtighten! Discharge Lines Connect quality sanitation hose 1” (25mm), Raritan 1” (25mm) Discharge Fitting part# SFH1, or 1 1/2” (38mm) I.D., Raritan part# SFH to discharge fitting on toilet (FIG 7).
  • Page 8 FIG 8 Intake Lines Pressurized Freshwater Models Install a shut off valve in intake line before water solenoid valve. Connect hose from shut off valve to inlet port of water solenoid valve (FIG 8). NOTE: To avoid malfunction of water solenoid due to debris in water, installation of Freshwater Strainer (190601) is recommended.
  • Page 9 Install strainer or KO2 kit in intake line to 3C. Sewage remaining in discharge line. avoid recurrence. 3B. Replace hose with Raritan sanitation hose (#SFH). 3C. Flush longer; replace hose if permeated; reroute hose making a shorter run or downward slope if possible.
  • Page 10 SeaEra QC model 162 PARTS LIST Additional Parts Included with Item Part# Description REMOTE MODELS 1237W Marine-size Bowl Item Part# Description 1244W Household-style Bowl 161135 Motor Cover 1236AW Bowl Spud Assembly 1660*A Intake Motor with Breaker 1236E Bowl Elbow (sea water only) 166000 Remote Intake Pump, 12V DC 221361...
  • Page 11 SeaEra QC Series Exploded Parts View Optional Fresh Water Strainer Optional Raw Water Strainer L365v0922jlc...
  • Page 12 5. No other person or entity is authorized to make any express warranty, promise or affirmation of fact or to assume any other liability on behalf of Raritan in connection with its products except as specifically set forth in this warranty.

This manual is also suitable for:

Seaera qc seriesSeaera 160mi012Seaera 160hi012