hit counter code
Download Print this page
Panasonic CS-MKS12NKU Information
Panasonic CS-MKS12NKU Information

Panasonic CS-MKS12NKU Information

Multi/split system wall mounted indoor unit - multi air conditioner
Hide thumbs Also See for CS-MKS12NKU:

Advertisement

Multi/Split System Submittal Data
Wall Mounted Indoor Unit - Multi Air Conditioner
CS-MKS12NKU
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/P/Hz
Circuit Ampacity
Fuse Size, Max.
Running Amps
Power Input
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
(RPM, High)
No. Motors
CFM
(HI/Med/Lo/QT* dB-A)
Operation Sound
Aluminum Plate Fin & Copper Tube
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Drain Connection Size
Refrigerant
(in. O.D. Discharge)
Line Size
(in. O.D. Discharge)
Line Size
(in.)
Dimensions
(Uncrated)
Indoor Unit
(Crated)
Weight
Net Shipping
Shipping Volume
General Data (at 230V)
230/1/60
(A)
(A)
(A)
(W)
Cross Flow
D3-11/16 L24-31/32 - 1
3 & Auto
8 - 1200
(W)
(HI)
36/33/29/25
Slit Plate - Inner Rif ed
2 - 19.5
(in.)
(in.)
1/4"(Flare)
3/8" (Flare)
H x W x D
11-7/32 x 32-15/32 x 7-7/16
13-25/32 x 35-7/16 x 10-1/32
(lbs.)
(lbs.)
(cu.ft.)
Approval:
Date:
Construction:
Unit #:
Drawing #:
15
20
.15
35
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity
Moisture Removal (HI)
47 - 1
282
Feature
Controls
Remote Controller
Temperature Control
Timer
2.02
Night Setback
9/32"
Air Louver
23/32"
Power Failure Automatic Restart
R410A
Heating/Cooling Automatic Changeover
Self-Diagnosis
Quiet Operation
Air Filter
Ion Generator
Air Clean Apatite Filer
Option
Indoor
Refrigerant Line Set
19.8
Fresh Air Intake
24.3
Airduct Extension
Indoor Frame Extension
Indoor
Condensate Drain Pump
2.82
Non-Removeable Remo-con Bracket
(BTU/H)
(Pint/H)
LCD Wireless Type, Temp. Sensor Built In
24 Hr. Program, 1 Hr. Of
(Horizontal)
(Vertical)
Washable, Anti-Mold
11,900
4.26
Microprocessor
IC Thermostat
Built-In
Manual
Automatic
Built-In
-
Built-In
Built-In
Equipped
Standard
Available
N/A
N/A
N/A
Available
Available

Advertisement

loading

Summary of Contents for Panasonic CS-MKS12NKU

  • Page 1 Multi/Split System Submittal Data Wall Mounted Indoor Unit - Multi Air Conditioner CS-MKS12NKU Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: General Data (at 230V) Power V/P/Hz 230/1/60 Circuit Ampacity Fuse Size, Max.
  • Page 2 Dimensions Operating Range Indoor Air Intake Temp. Outdoor Air Intake Temp. Cooling (CM Model) 95F DB/71F WB 115F DB Maximum 67F DB/57F WB 67F DB Minimum Note (CLM Model): 1 32F DB: When combinded with KMS1872 or KMS2472 23F DB: When combinded with KMS0772, KMS0972, or KMS1272...