Page 2
This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright. No information contained herein may be copied, translated, transcribed or duplicated for any commercial purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics Co., Ltd.
CHAPTER 2. Installing Cabinets Describes how to install an OfficeServ 7200 cabinet on the ground, inside rack or on a wall, depending on the installation environment, and how to connect the grounding wire. CHAPTER 3. Mounting and Replacing Boards Describes how to mount and replace various boards of the OfficeServ 7200.
OfficeServ 7200. CHAPTER 8. Starting the System Describes items to check before starting the OfficeServ 7200, the procedure for starting the system, and the procedure for testing whether the system is normally operating after startup.
Describes the programming for the system overview, specification, hardware circuit configuration and feature, troubleshooting, maintenance. OfficeServ 7200 Data Server User Guide Describes the data server, which is the OfficeServ 7200 application software and describes the installation and operation procedure. OfficeServ 7200 Data Server Operation Manual Describes to set the data server according to the OfficeServ 7200 function.
Original 05. 2005. - Modifying the brand name (Before: OfficeServ SME Installation Guide, After: OfficeServ 7200 Installation Manual) - Modifying edit format (Deleting ED at page header) - Modifying cover page design and overall edit format and improving sentence expression...
OfficeServ 7200 Installation Manual SAFETY CONCERNS For product safety and correct operation, the following information must be given to the operator/user and shall be read before the installation and operation. Symbols Caution Indication of a general caution Restriction Indication for prohibiting an action for a product...
Warning WARNING Cautions for grounding - Do not connect the grounding wire of the OfficeServ 7200 to a power conduit of a building. - The standards for power and grounding should comply with the country standard and the pertinent work should be conducted according to the country standard.
OfficeServ 7200 Installation Manual Caution CAUTION Caution for Mounting a Board This product uses an air flow method by a forced air cooling with a fan. Therefore, an empty slot may have a bad influence on the system operation by lowering cooling efficiency.
Page 12
Ошибка! Используйте вкладку "Главная" для применения 제목 8,표준 제목 1 к тексту, который должен здесь отображаться. Non-allowed AC Power Connection to Other Equipment Do not use the AC power of the OfficeServ 7200 or the DC power of an external battery to operate other equipment. Caution for Installation Only a trained service staff can install the OfficeServ 7200.
Page 13
OfficeServ 7200 Installation Manual AC Power Use the stable power for the AC power of the system. Temporary power failure caused by the unstable power supply may cause system fault or battery failure. Mounting or Dismounting a Board Before replacing a board which can be mounted or dismounted while the system is operating, make sure to disconnect the cables connected at the front of the system.
Page 17
OfficeServ 7200 Installation Manual 7.1.5 Connecting an IP Phone ......................7-7 7.1.6 Connecting a Wireless LAN Access Point ................7-11 7.1.7 Connecting to a Door Phone and a Door Lock ..............7-12 7.1.8 Connecting KDB-D/KDB-S ....................7-14 Connecting Additional Equipment ..................7-15 7.2.1...
Page 19
OfficeServ 7200 Installation Manual Figure 3.24 Connecting a Shunting Phone Line for Power Failure Protection ...... 3-28 Figure 3.25 Turning the Cabinet Power Off ................3-29 Figure 3.26 Removing Cable ....................3-29 Figure 3.27 Removing Board....................3-30 Figure 3.28 Replacing to New Board ..................3-30 Figure 4.1 Connecting an External Battery ................
Page 21
Table 3.17 Setting Switch of the 2BRM ................3-23 Table 3.18 Types of Interface Board and Applicable Slots ............ 3-25 Table 6.1 OfficeServ 7200 Line Conditions................6-1 Table 7.1 Distance Between Stations and the System ............7-1 Table 7.2 Power Consumption by Terminal Type ..............7-2 Table 7.3 Maximum Mountable Capacities When Only the Built-in Power Is Used ....
1.1.1 Safety Conditions The OfficeServ 7200 should not be installed near materials that can cause a fire, such as explosive gas and inflammables. The OfficeServ 7200 should not be near equipments that generate electromagnetic waves, such as monitors or copying machines.
Cautions for Grounding - Do not connect the grounding wire of the OfficeServ 7200 to a power conduit of a building. - The standards for power and grounding should comply with the country standard and the pertinent work should be conducted according to the country standard.
OfficeServ 7200 Installation Manual 1.3 Power Conditions The power supply unit of the OfficeServ 7200 receives AC input power or battery power, and supplies -48 V, -5 V, +3.3 V, +5 V, +12 V, and -54 V (for backup) to the system cabinet.
CHAPTER 1. Ошибка! Используйте вкладку "Главная" для применения 제목 1 к тексту, который должен здесь отображаться. 1.4 Checking the Package The list of items included in the OfficeServ 7200 package is as follows. Table 1.2 Packages Category Name Quantity Remark...
6) Connect AC 220~240 V input power. 2.2 Selecting Installation Method The OfficeServ 7200 cabinet can be installed on the floor, inside a 19-inch rack or on a wall depending on the number of cabinets and environment of the installation area.
CHAPTER 2. Ошибка! Используйте вкладку "Главная" для применения 제목 1 к тексту, который должен здесь отображаться. 2.3 Installing in a Rack This section describes how to install the OfficeServ 7200 cabinet inside a 19-inch rack. 2.3.1 Cautions for Installation Take the following cautions when installing the OfficeServ 7200 cabinet inside a rack: ...
OfficeServ 7200 Installation Manual 2.3.3 Installing in a Rack The procedure for installing the OfficeServ 7200 cabinet inside a 19-inch rack is as follows: 1) Attach the cabinet bracket to the bottom surface of the OfficeServ 7200 cabinet and fasten the bracket firmly with the three screws.
OfficeServ 7200 Installation Manual 2.4 Installing on a Wall This section describes how to install the OfficeServ 7200 cabinet on a wall. 2.4.1 Required Tools A middle-sized cross screwdriver An electric drill A hammer A wall bracket ...
отображаться. 2.4.2 Wall Installation The procedure for installing the OfficeServ 7200 cabinet on a wall by using a wall bracket is as follows: 1) There are four screw holes (A in Figure 2.7) on the wall bracket as shown below.
OfficeServ 7200 Installation Manual 4) Once the wall bracket is fixed to the wall, put a cross screw into the plastic anchor and tighten the screw with the screwdriver. Figure 2.10 Wall Installation (4) 5) There are two screws inside of two holes among four holes at the bottom of OfficeServ 7200 cabinet as shown below.
отображаться. 6) Tighten the mounting screws on two holes which do not have screws like at the bottom of OfficeServ 7200 cabinet. Do not tighten the screws to the end but leave about 2 mm space. Figure 2.12 Wall Installation (6) 7) Hang the screws on the bottom surface of the OfficeServ 7200 cabinet to the holes of wall bracket and push the cabinet downward to fix the cabinet.
AC power grounding. As shown in the figure below, earth to the ground lug behind the OfficeServ 7200. For an extension cabinet, connect and ground the external ground wire between the extension cabinet and a basic cabinet.
OfficeServ 7200 Installation Manual CHAPTER 3. Mounting and Replacing Boards This chapter describes how to mount and replace various boards of the OfficeServ 7200. 3.1 Cabinet Configuration The basic and expansion cabinets of the OfficeServ 7200 have six slots. Slot 0...
14 (CRM 1) 16 (IRM 1) In OfficeServ 7200 with MP20S, the total number of MFR & Mobex is fixed at 14. The minimum of each channels are 6, and can be expanded to 8. If the user wants to use 8 MFR channels, the Mobex channels will be 6 channels, and vice versa.
In case of the unconditional group ring, ring group or paging, each member has one call. - * In OfficeServ 7200 with MP20S, the IP-UMS, IVR and ACD features are not supported. - ** The capacity for the PCM trunk is considered that two TEPRIa are used. So, in case of U.S.A, the PCM trunk number is 48, and the others are 60.
Lug for grounding system communication. External rectifier socket Supplies an external power to Power over Ethernet (PoE). Power switch Switches the power of OfficeServ 7200 on/off. Power connector between a Supplies the power supplied to the basic cabinet an basic cabinet and an extension extension cabinet.
OfficeServ 7200 Installation Manual 3) Align the connectors of the MP20 to that of the optional boards (MIS, RCM2, CRM, IRM and MODEM), and firmly press the optional boards downward with two hands. LOC1 LOC2 LOC3 Figure 3.4 MP20 Mounting Optional Boards Table 3.8 MP20 Mounting Locations of Optional Boards...
OfficeServ 7200 Installation Manual Table 3.9 MP20 maximum resource capabilities with Optional Boards(Continued) # of resources # of resources TOTAL Option Card BASE Remark of Loc #1 of Loc #2 RESOURCE Loc #1 Loc #1 Loc #2 NONE (MFR) RCM2...
OfficeServ 7200 Installation Manual 3.2.2 Mounting Control Boards Mount control boards on slot 0 of the basic cabinet and the expansion cabinet. The locations of slot 0 through slot 5 are described in the ‘3.1. Cabinet Configuration’ section of this chapter.
OfficeServ 7200 Installation Manual 3.2.3 Connecting MP20 to LCP If the OfficeServ 7200 consists of a basic cabinet and an extension cabinet, connect the MP20 to the LCP using extension cables to transmit and receive signals between the control boards.
OfficeServ 7200 Installation Manual 3.3.1.4 TEPRIa TEPRIa (T1E1Primary Rate Interface advanced), which provides a digital C.O. line, supports E1, T1 and ISDN PRI port, and provides the Q-SIG function. Set S2 switch and jumpers of the TEPRIa as follows: Setting Switch...
OfficeServ 7200 Installation Manual Interlocking with IP phones via PLIM If the system interworks with IP phones from the internal power via the PLIM, up to 16 IP phone can be interworked and the remained Digital Phone (DGP) can be interworked up to 24 DGP on the basis of 2-line LCD.
OfficeServ 7200 Installation Manual 3.3.1.6 GSIMT GSIMT (Gigabit Switch Interface Module TX) provides the Giga bit LAN interface of Layer 2 and Layer 3 to support data network. Set the jumper of the GSIMT. Jumper Setting When using the internal rectifier: Connect the shunt pins (J3, J4) to pins 1 and 2.
OfficeServ 7200 Installation Manual 3.3.1.8 2BRM The 2BRM (Basic Rate interface Module) is mounted on UNI and provides two 2B + 1D digital trunk ports. This module is connected to 4 channel ISDN trunk in S and T mode. In S mode do not support DC power feeding...
OfficeServ 7200 Installation Manual 3.3.2 Mounting Interface Board to Slot Interface boards are mounted on slot 1 through slot 5 of each cabinet. The following table describes the slots locations for interface boards. The locations of Slot 0 through slot 5 of the cabinet are described in ‘3.1 Cabinet Configuration’.
Page 62
отображаться. Reference For detail information on functions and characteristics of each Interface board, refer to ‘OfficeServ 7200 System Description’. Mounting the GSIMT Only one GSIMT can be mounted per the cabinet. If you mount boards more than the capacity limit, it may cause malfunction of the PSU due to overload.
OfficeServ 7200 Installation Manual 3.5 Replacing Boards If the OfficeServ 7200 fails to operate normally due to an error on the power supply board, control board, or interface board, replace the board to a new one. Removing Cables Replace a board after removing all cables connected to the board.
4) Align the new board to the guardrails of the slot, and slide the new board into the slot. Push the front panel lever of the MP20/MP20S until it is completely inserted into the OfficeServ 7200 main board port. Figure 3.28 Replacing to New Board...
4.1 Connecting External Batteries Cautions for connecting external batteries External batteries are required to ensure stable operation of the OfficeServ 7200 in case a power failure occurs. Rated capacity of an external battery is DC 48 V and 45 AH per cabinet.
(-) terminal of the battery. Then, connect the other end of the battery cable to the external battery socket on the rear panel of the OfficeServ 7200 cabinet. When using two or more OfficeServ cabinets, prepare as much external batteries as the number of cabinets and connect the batteries to each cabinet.
The external rectifier is an external power supply that provides the power to IP phones connected to the OfficeServ 7200 when the PLIM, PLIM2, or GPLIMT board is used. Since the capacity of the internal power is not sufficient for external equipment, additional power supply is required.
The external battery to be connected to an external rectifier has the same capacity as the external battery used in the OfficeServ 7200. In addition, it is handled in the same way and with the same cautions. For details about the capacity of the external battery, refer to ‘4.1 Connecting external battery’.
(110 V for U.S.A.). Make sure that the input power of the OfficeServ 7200 is AC 220 V (110 V for U.S.A.) and other electric devices, such as motors and compressors, do not use the same input power.
5.2 Procedure for Connecting Power Single Cabinet Configuration Use the power cable provided with the OfficeServ 7200 to connect the input power terminal on the rear panel of the cabinet to a grounded outlet. Figure 5.1 Connecting Power (for Single Cabinet)
OfficeServ 7200 Installation Manual Or, connect the input power terminal of the basic cabinet to the grounded outlet, and use an power extension cable to connect the power connectors of the basic and expansion cabinet. Expansion Cabinet Basic Cabinet Figure 5.3 Connecting Power (using Power Extension Cable)
OfficeServ 7200 Installation Manual CHAPTER 6. Connecting C.O. Lines This chapter describes how to connect C.O. lines to the OfficeServ 7200 after installation. 6.1 Line Conditions Cautions for connecting C.O. lines are as follows: Cables with AWG #24 or AWG #26 should be used as subscriber lines.
Connecting to the 8TRK Board and 4TRM Daughter Board Use a pair of cable with AWG #24 (or AWG #26) width to connect a common C.O. line to the terminal pin of a terminal box connected to the OfficeServ 7200 equipped with an 8TRK.
OfficeServ 7200 Installation Manual Connecting to the 8TRK2 Connect a general trunk line to a pin of the terminal block connected to the OfficeServ 7200 where the 8TRK2 is mounted using a pair of AWG #24 (or AWG #26) cables.
6.2.4 Connecting a Leased Line You can connect E & M, DID, and R/D leased lines to the 4HTRK through the RJ-45 port. As shown below, connect the E & M, DID, and R/D ports in the OfficeServ 7200. E & M/DID/R/D Port (RJ-45) Figure 6.5 RJ-45 Port of the 4HTRK...
OfficeServ 7200 Installation Manual 6.2.5 Connecting a BRI 4BRI and 2BRM can be connected to BRI lines through a RJ-45 port. As shown below, connect BRI lines to the 4BRI and 2BRM port of the OfficeServ 7200. P1-T~P4-T port (RJ-45) Figure 6.6 RJ-45 Port of the 4BRI...
Connecting Stations and Additional Equipment This chapter describes how to connect various stations and additional equipment, such as analog/digital phones, door phones and door locks, to the OfficeServ 7200. 7.1 Connecting Stations 7.1.1 Cautions for Connecting Stations Take the following cautions when connecting stations.
IP Phone 2-Line LCD IP Keyset (ITP-5112L) 5.7 W Below are the maximum capacities of the terminals which can be connected when only the built-in power of the OfficeServ 7200 is used. Table 7.3 Maximum Mountable Capacities When Only the Built-in Power Is Used Terminal Type...
7.1.2 Connecting an Analog Phone Connect an analog phone to the 8SLI2, 8SLI3, 16SLI2, 16SLI3, 16MWSLI, 8COMBO2, 8COMBO3, 4SLM, 4SL2 mounted on the OfficeServ 7200. Connecting to the 8SLI2/8SLI3 Connect a general analog phone to a port of the 8SLI2 using a pair of AWG #24 (or AWG #26) cables.
OfficeServ 7200 Installation Manual 7.1.3 Connecting a Digital Phone Connect a digital phone to 8DLI, 16DLI2, 8COMBO2, 8COMBO3, 4DLM. Connecting to the 8DLI Connect a digital phone to the 8DLI by using a pair AWG #24 or AWG #26 cables.
Up to eight DS-5012L phones can be connected to each DLI board (8DLI) of the OfficeServ 7200. If nine or more DS-5012L phones are connected to the DLI board, the power provided to all digital phones connected to the same board is turned off automatically.
7.1.5 Connecting an IP Phone IP phone enables calls through the Ethernet LAN. The interface between a digital phone connected to the OfficeServ 7200 and an IP phone connected to LAN is as follows: 1) The connection between a digital phone and an IP phone is established or released using the IP address of the LAN connected to the OfficeServ 7200.
OfficeServ 7200 Installation Manual Voice Digital Phone MGI16/OAS IP Phone Analog Packet data Voice PCM data Analog conversion PCM data conversion 16DLI2 conversion Packet data Digital Phone IP Phone Voice Analog Analog Packet data Voice PCM data conversion Packet data...
OfficeServ 7200 Installation Manual 7.1.6 Connecting a Wireless LAN Access Point Wireless LAN service offered by the OfficeServ 7200 requires the following equipment: SMT-R2000: Wireless LAN Access Point (AP) SMT-W5100: Wireless LAN IP phone Table 7.4 Specification for Wireless LAN Connection...
отображаться. 7.1.7 Connecting to a Door Phone and a Door Lock Connect a door phone and a door lock to the OfficeServ 7200 by using a Door Phone Interface Module (DPIM). 1) Connect a pair of #24 AWG or #26 AWG cables to the LINE port of DPIM and to P1 through P8 of 8DLI/16DLI2, D1 through D8 of 8COMBO2/8COMBO3 and P1 through P4 of 4DLM of the OfficeServ 7200.
PCMMC/SMDR/CTI, to the OfficeServ 7200. 7.2.1 Connecting MOH/BGM Equipment The OfficeServ 7200 offers music when while on hold. The system provides internal tone/music and external music sources per C.O. or extension lines as the music source. The selection of internal/external music sources is performed through MMC 861.
MMC Related Select music sources for C.O. lines through MMC 408 and music sources for extensions through MMC 308. For full and detailed instruction on the MMC program, refer to ‘OfficeServ 7200 Programming Manual’ in http://www.samsungdocs.co.kr. 7.2.2 Connecting External/Additional Page Equipment...
OfficeServ 7200 Installation Manual MP20S supports the channels for external broadcasting and one dry contact. If a pair of External Page Equipment lines is connected to pin3 and pin6, Dry Contact 1 lines is connected to pin1 and pin2, Dry Contact 2 lines is connected to pin7 and pin8 of the MISC port in MP20S.
OfficeServ 7200 Installation Manual 7.2.4 Connecting Installation Tool The system maintenance software is installed on a PC for programming. The Installation Tool is an application that provides various functions necessary for system maintenance. You can use the Installation Tool when you need to install a new system component or change a system component or modify the database.
7.2.4.1 Connecting a PC for Programming Using a LAN Port You can connect a PC where the Installation Tool is installed to the OfficeServ 7200 using a LAN port. The Installation Tool allows you to manage the OfficeServ 7200 remotely.
3) When the <Link Control> is displayed, enter the name of the system in the [Name] field. 4) If the Link Type is LAN, enter the IP address of the OfficeServ 7200 in the [IP Address] field. If the Link Type is MODEM enter the internal modem number of the OfficeServ 7200 in the [Telephone] field.
Page 102
‘Configuring the network parameter of NMS Server to send alarm using MMC 830 program’. Configuring the network parameters using the MMC 830 program This step configures the network parameters of the OfficeServ 7200. Consult your network administrator for the network parameter values. 1) Set the IP address of the OfficeServ 7200.
PC. Setting Network parameter by using the MMC830 program Set the network parameter of OfficeServ 7200 with MP20S. For the setting value of the network parameter, contact the network administrator. 1) Set the IP address of OfficeServ 200 with MP20S.
OfficeServ 7200 Installation Manual 7.2.7 Connecting a Printer The OfficeServ 7200 can connect to a printer. The system can print various call information or event information created by the system. A printer can be connected through the LAN port of the LIM board or the WIM.
OfficeServ 7200 Installation Manual CHAPTER 8. Starting the System This chapter describes items to check before starting the OfficeServ 7200, the procedure for starting the system, and the procedure for testing whether the system is normally operating after startup. 8.1 Pre-Check This section describes items to check before starting the OfficeServ 7200.
Page 108
CHAPTER 8. Ошибка! Используйте вкладку "Главная" для применения 제목 1 к тексту, который должен здесь отображаться. 8.1.2 Safety Conditions The building where the OfficeServ 7200 is installed should have lightning rods and grounding to protect the system against lightning and electric leakage. ...
Page 109
1) Check if the boards and cables are properly mounted and connected to the OfficeServ 7200 cabinet. 2) Turn on the power of the OfficeServ 7200 basic cabinet, and turn on the power of the expansion cabinet. 3) Check the LEDs of the MP20/MP20S and LCP.
According to the setting of the S3 switch (SW6, SW7, SW8) of the MP20/MP20S /LCP, the OfficeServ 7200 assigns 3 or 4 digits to C.O. lines, extensions, and extension groups. Refer to ‘Chapter 4. Mounting and Replacing Boards’ of this manual for details on setting the S3 switch.
8.4 Checking System Operation After starting the OfficeServ 7200, check if the system is operating normally. Check if the basic functions of the OfficeServ 7200, such as Station Call, Station Camp-On, C.O. Line Call, and C.O. Line Camp-On are properly executed.
OfficeServ 7200 Installation Manual 8.4.5 Checking if the fan is in normal operation When the fan connected to the system is not operating, the 48 DC power and the system operation will be turned off to prevent the system overheating.
If you want to use AA function not VM, there is no need to enter license key. 8.4.9 Clock Chip Backup The clock chip of the OfficeServ 7200 is designed to back itself up even while the power is turned off.
OfficeServ 7200 Installation Manual ABBREVIATION Automatic Function Test Add On Module Access Point American Wire Gauge Basic Rate Interface Basic Rate interface Module Conference Computer Telephony Integration Digital Phone Digital Line Interface Digital Line interface Module DPIM Door Phone Interface Module...
Page 117
OfficeServ 7200 Installation Manual TEPRIa T1E1 Primary Rate Interface advanced Trunk Trunk Module Universal Unshielded Twisted Pair VLAN Virtual Local Area Network Voice Mailing System Wide Area Network WAN Interface Module WIMD WAN Interface Module Daughter board This page is intentionally left blank.